메뉴 건너뛰기




Volumn 13, Issue 2, 2006, Pages 134-140

Characterization and mitigation of stray radiofrequency currents during monopolar resectoscopic electrosurgery

Author keywords

Active electrode monitoring; Electrosurgery; Endometrial ablation; Hysteroscopy; Monopolar; Resectoscope

Indexed keywords

GLYCINE;

EID: 33644751852     PISSN: 15534650     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jmig.2005.12.001     Document Type: Article
Times cited : (22)

References (19)
  • 1
    • 84942946783 scopus 로고
    • Removal of neoplasms of the urinary bladder: A new method employing high frequency (Oudin) currents through a catheterizing cystoscope
    • E. Beer Removal of neoplasms of the urinary bladder a new method employing high frequency (Oudin) currents through a catheterizing cystoscope JAMA. 54 1910 1768 1769
    • (1910) JAMA. , vol.54 , pp. 1768-1769
    • Beer, E.1
  • 2
    • 0017193206 scopus 로고
    • Excision of submucous fibroids with hysteroscopy control
    • R.S. Neuwirth, H.K. Amin Excision of submucous fibroids with hysteroscopy control Am J Obstet Gynecol.. 126 1976 95 99
    • (1976) Am J Obstet Gynecol. , vol.126 , pp. 95-99
    • Neuwirth, R.S.1    Amin, H.K.2
  • 3
    • 0030858910 scopus 로고    scopus 로고
    • Genital tract burns during rollerball endometrial coagulation
    • G.A. Vilos, I. D'Souza, D. Huband Genital tract burns during rollerball endometrial coagulation J Am Assoc Gynecol Laparosc. 4 1997 273 276
    • (1997) J Am Assoc Gynecol Laparosc. , vol.4 , pp. 273-276
    • Vilos, G.A.1    D'Souza, I.2    Huband, D.3
  • 4
    • 0034053816 scopus 로고    scopus 로고
    • Genital tract electrical burns during hysteroscopic endometrial ablation: Report of 13 cases in the United States and Canada
    • G.A. Vilos, S. Brown, G. Graham Genital tract electrical burns during hysteroscopic endometrial ablation report of 13 cases in the United States and Canada J Am Assoc Gynecol Laparosc. 7 2000 141 147
    • (2000) J Am Assoc Gynecol Laparosc. , vol.7 , pp. 141-147
    • Vilos, G.A.1    Brown, S.2    Graham, G.3
  • 5
    • 33644751051 scopus 로고    scopus 로고
    • Vaginal burns in a patient during rollerball endometrial ablation [Letter]
    • P.L. Langlois Vaginal burns in a patient during rollerball endometrial ablation [Letter] J Am Assoc Gynecol Laparosc. 7 2000 557 558
    • (2000) J Am Assoc Gynecol Laparosc. , vol.7 , pp. 557-558
    • Langlois, P.L.1
  • 6
    • 0035070785 scopus 로고    scopus 로고
    • Three spectra of laparoscopic entry access injuries
    • J.G. Chandler, S.L. Corson, L.W. Way Three spectra of laparoscopic entry access injuries J Am Coll Surg. 192 2001 478 491
    • (2001) J Am Coll Surg. , vol.192 , pp. 478-491
    • Chandler, J.G.1    Corson, S.L.2    Way, L.W.3
  • 7
    • 0032324662 scopus 로고    scopus 로고
    • The medicolegal risks of thermal injury during laparoscopic monopolar electrosurgery
    • P.G. Perantinides, A.P. Tsarouhas The medicolegal risks of thermal injury during laparoscopic monopolar electrosurgery J Healthc Risk Manage. 1998 49 55 winter
    • (1998) J Healthc Risk Manage. , pp. 49-55
    • Perantinides, P.G.1    Tsarouhas, A.P.2
  • 9
    • 0346103708 scopus 로고    scopus 로고
    • Factors affecting capacitive current diversion with a uterine resectoscope: An in-vitro study
    • M.G. Munro Factors affecting capacitive current diversion with a uterine resectoscope an in-vitro study J Am Assoc Gynecol Laparosc. 10 2003 450 640
    • (2003) J Am Assoc Gynecol Laparosc. , vol.10 , pp. 450-640
    • Munro, M.G.1
  • 10
    • 4444334204 scopus 로고    scopus 로고
    • Capacitive coupling: A comparison of measurements in four uterine resectoscopes
    • M.G. Munro Capacitive coupling a comparison of measurements in four uterine resectoscopes J Am Assoc Gynecol Laparosc. 11 2004 379 387
    • (2004) J Am Assoc Gynecol Laparosc. , vol.11 , pp. 379-387
    • Munro, M.G.1
  • 11
    • 0004258659 scopus 로고
    • Wiley Medical New York, NY
    • J.A. Pearce Electrosurgery 1986 Wiley Medical New York, NY 194 199
    • (1986) Electrosurgery , pp. 194-199
    • Pearce, J.A.1
  • 12
    • 0015582730 scopus 로고
    • The distribution of radiofrequency current and burns
    • C.M. Becker, I.V. Malhotra, J.H. Whyte The distribution of radiofrequency current and burns Anesthesiology. 38 1973 106 122
    • (1973) Anesthesiology. , vol.38 , pp. 106-122
    • Becker, C.M.1    Malhotra, I.V.2    Whyte, J.H.3
  • 13
    • 0026896784 scopus 로고
    • Capacitive coupled stray currents during laparoscopic and endoscopic electrosurgical procedures
    • R.D. Tucker, R.C. Voyles, S.E. Silvis Capacitive coupled stray currents during laparoscopic and endoscopic electrosurgical procedures Biomed Instrum Technol. 26 1992 303 311
    • (1992) Biomed Instrum Technol. , vol.26 , pp. 303-311
    • Tucker, R.D.1    Voyles, R.C.2    Silvis, S.E.3
  • 14
    • 0017596473 scopus 로고
    • Capacitive effects during transurethral resections with high frequency currents
    • G. Flachenecker, K. Fastenmeier Capacitive effects during transurethral resections with high frequency currents Urologe. 16 1977 25 27
    • (1977) Urologe. , vol.16 , pp. 25-27
    • Flachenecker, G.1    Fastenmeier, K.2
  • 16
    • 0018689359 scopus 로고
    • High frequency current effects during transurethral resection
    • G. Flachenecker, K. Fastenmeier High frequency current effects during transurethral resection J Urol. 122 1979 336 341
    • (1979) J Urol. , vol.122 , pp. 336-341
    • Flachenecker, G.1    Fastenmeier, K.2
  • 17
    • 33644775285 scopus 로고    scopus 로고
    • A randomized trial to compare the differences between monopolar surgery (loop resection) with glycine 1.5% and bipolar surgery with saline (Olympus, Versapoint) on hysteroscopic surgery
    • A. Berg, O. Istre A randomized trial to compare the differences between monopolar surgery (loop resection) with glycine 1.5% and bipolar surgery with saline (Olympus, Versapoint) on hysteroscopic surgery J Minim Invasive Gynecol. 12 2005 S3
    • (2005) J Minim Invasive Gynecol. , vol.12 , pp. 3
    • Berg, A.1    Istre, O.2
  • 18
    • 0033215291 scopus 로고    scopus 로고
    • Intrauterine surgery using a new coaxial bipolar electrode in normal saline solution (Versapoint): A pilot study
    • G.A. Vilos Intrauterine surgery using a new coaxial bipolar electrode in normal saline solution (Versapoint) a pilot study Fertil Steril. 72 1999 740 743
    • (1999) Fertil Steril. , vol.72 , pp. 740-743
    • Vilos, G.A.1
  • 19
    • 0035161654 scopus 로고    scopus 로고
    • Gas embolism during Versapoint hysteroscopic myomectomy: Case report
    • D.C. Hunter, D.W. Cooper, G. Phillips Gas embolism during Versapoint hysteroscopic myomectomy case report Gynecol Endosc. 10 2001 261 264
    • (2001) Gynecol Endosc. , vol.10 , pp. 261-264
    • Hunter, D.C.1    Cooper, D.W.2    Phillips, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.