메뉴 건너뛰기




Volumn 46, Issue 3, 2006, Pages 352-364

End-to-end electronic control of the hospital transfusion process to increase the safety of blood transfusion: Strengths and weaknesses

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD GROUP; BLOOD SAMPLING; BLOOD STORAGE; BLOOD TRANSFUSION; CLINICAL PRACTICE; COMPUTER; CONTROLLED STUDY; DOCUMENTATION; HEART SURGERY; HUMAN; MEDICAL AUDIT; MEDICAL STAFF; MEDICAL TECHNOLOGY; RISK ASSESSMENT; VALIDATION PROCESS;

EID: 33644699451     PISSN: 00411132     EISSN: 15372995     Source Type: Journal    
DOI: 10.1111/j.1537-2995.2006.00729.x     Document Type: Article
Times cited : (65)

References (16)
  • 2
    • 0033787643 scopus 로고    scopus 로고
    • Transfusion errors in New York state: An analysis of 10 years experience
    • Linden J Wagner K Voytovich A Sheehan J Transfusion errors in New York state: an analysis of 10 years experience Transfusion 2000 40 1207 13
    • (2000) Transfusion , vol.40 , pp. 1207-13
    • Linden, J.1    Wagner, K.2    Voytovich, A.3    Sheehan, J.4
  • 3
    • 0026669178 scopus 로고
    • A report of 104 transfusion errors in New York State
    • Linden J Paul B Dressler K A report of 104 transfusion errors in New York State Transfusion 1992 32 601 6
    • (1992) Transfusion , vol.32 , pp. 601-6
    • Linden, J.1    Paul, B.2    Dressler, K.3
  • 4
    • 0028349661 scopus 로고
    • Errors in blood transfusion in Britain: Survey of hospital haematology departments
    • McClelland D Phillips P Errors in blood transfusion in Britain: survey of hospital haematology departments Br Med J 1994 308 1205 6
    • (1994) Br Med J , vol.308 , pp. 1205-6
    • McClelland, D.1    Phillips, P.2
  • 5
    • 0018966577 scopus 로고
    • Fatalities from blood transfusion
    • Myhre B Fatalities from blood transfusion J Am Med Assoc 1980 244 1333 5
    • (1980) J Am Med Assoc , vol.244 , pp. 1333-5
    • Myhre, B.1
  • 6
    • 0033866994 scopus 로고    scopus 로고
    • Human error - A significant cause of transfusion mortality
    • Myhre B McRuer D Human error - a significant cause of transfusion mortality Transfusion 2000 40 879 85
    • (2000) Transfusion , vol.40 , pp. 879-85
    • Myhre, B.1    McRuer, D.2
  • 7
    • 0042334908 scopus 로고    scopus 로고
    • Barcode technology: Its role in increasing the safety of transfusion
    • Turner CL Casbard A Murphy MF Barcode technology: its role in increasing the safety of transfusion Transfusion 2003 43 1200 9
    • (2003) Transfusion , vol.43 , pp. 1200-9
    • Turner, C.L.1    Casbard, A.2    Murphy, M.F.3
  • 8
    • 6544280251 scopus 로고    scopus 로고
    • Guidelines for administration of blood and blood components and the management of transfused patients
    • British Committee for Standards in Haematology.
    • British Committee for Standards in Haematology. Guidelines for administration of blood and blood components and the management of transfused patients Transfus Med 1999 9 227 38
    • (1999) Transfus Med , vol.9 , pp. 227-38
  • 9
    • 4344700297 scopus 로고    scopus 로고
    • A comprehensive assessment program to improve blood-administering practices using the FOCUS-PDA model
    • Saxena S Ramer L Shulman IA A comprehensive assessment program to improve blood-administering practices using the FOCUS-PDA model Transfusion 2004 44 1350 6
    • (2004) Transfusion , vol.44 , pp. 1350-6
    • Saxena, S.1    Ramer, L.2    Shulman, I.A.3
  • 10
    • 0034107712 scopus 로고    scopus 로고
    • Errors in interpreting the pretransfusion bedside compatibility test
    • Dujardin PP Salmi LR Ingrand P Errors in interpreting the pretransfusion bedside compatibility test Vox Sang 2000 78 37 43
    • (2000) Vox Sang , vol.78 , pp. 37-43
    • Dujardin, P.P.1    Salmi, L.R.2    Ingrand, P.3
  • 11
    • 0025816639 scopus 로고
    • Improvement in transfusion safety using a new blood unit and patient identification system as part of safe transfusion practice
    • Wenz B Burns ER Improvement in transfusion safety using a new blood unit and patient identification system as part of safe transfusion practice Transfusion 1991 31 401 3
    • (1991) Transfusion , vol.31 , pp. 401-3
    • Wenz, B.1    Burns, E.R.2
  • 12
    • 0029913895 scopus 로고    scopus 로고
    • A cost-effectiveness analysis of the use of a mechanical barrier system to reduce the risk of mistransfusion
    • Aubuchon JP Littenberg B A cost-effectiveness analysis of the use of a mechanical barrier system to reduce the risk of mistransfusion Transfusion 1996 36 222 6
    • (1996) Transfusion , vol.36 , pp. 222-6
    • Aubuchon, J.P.1    Littenberg, B.2
  • 13
    • 0030050966 scopus 로고    scopus 로고
    • Bedside transfusion errors. analysis of 2 years' use of a system to monitor and prevent transfusion errors
    • Mercuriali F Inghilleri G Colotti MT et al. Bedside transfusion errors. analysis of 2 years' use of a system to monitor and prevent transfusion errors Vox Sang 1996 70 16 20
    • (1996) Vox Sang , vol.70 , pp. 16-20
    • Mercuriali, F.1    Inghilleri, G.2    Colotti, M.T.3
  • 14
    • 33644679041 scopus 로고    scopus 로고
    • Survey of the implementation of the recommendations in the Health Service Circular 2002/009 "better Blood Transfusion."
    • Murphy MF Howell C Survey of the implementation of the recommendations in the Health Service Circular 2002/009 "Better Blood Transfusion." Transfusion Med 2005 15 453 60
    • (2005) Transfusion Med , vol.15 , pp. 453-60
    • Murphy, M.F.1    Howell, C.2
  • 16
    • 22844447868 scopus 로고    scopus 로고
    • Bar coding for patient safety
    • Wright AA Katz IT Bar coding for patient safety N Engl J Med 2005 353 329 31
    • (2005) N Engl J Med , vol.353 , pp. 329-31
    • Wright, A.A.1    Katz, I.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.