메뉴 건너뛰기




Volumn 46, Issue 11, 2005, Pages 4153-4158

Asymmetry in optic disc morphometry as measured by Heidelberg Retina Tomography in a normal elderly population: The Bridlington Eye Assessment Project

Author keywords

[No Author keywords available]

Indexed keywords

AGED; AGING; ARTICLE; CLINICAL ASSESSMENT; FEMALE; GLAUCOMA; HUMAN; MALE; MEASUREMENT; MORPHOMETRICS; NORMAL HUMAN; OPTIC DISK; POPULATION RESEARCH; PRIORITY JOURNAL; RETINA; UNITED KINGDOM; VISUAL ACUITY; HISTOLOGY; LASER; MASS SCREENING; METHODOLOGY; PHYSIOLOGY; REFERENCE VALUE; THREE DIMENSIONAL IMAGING; TOMOGRAPHY; VISUAL FIELD; VISUAL SYSTEM EXAMINATION;

EID: 33644685247     PISSN: 01460404     EISSN: None     Source Type: Journal    
DOI: 10.1167/iovs.05-0423     Document Type: Article
Times cited : (24)

References (23)
  • 1
    • 0028358583 scopus 로고
    • Reproducibility of the optic nerve head topography with a new laser tomographic scanning device
    • Rohrschneider K, Burk RO, Kruse FE, Volcker HE. Reproducibility of the optic nerve head topography with a new laser tomographic scanning device. Ophthalmology. 1994;101:1044-1049.
    • (1994) Ophthalmology , vol.101 , pp. 1044-1049
    • Rohrschneider, K.1    Burk, R.O.2    Kruse, F.E.3    Volcker, H.E.4
  • 2
    • 0038692875 scopus 로고    scopus 로고
    • Detection of glaucomatous visual field changes using the Moorfields regression analysis of the Heidelberg retina tomograph
    • Miglior S, Guareschi M, Albe E, et al. Detection of glaucomatous visual field changes using the Moorfields regression analysis of the Heidelberg retina tomograph. Am J Ophthalmol. 2003;136:26-33.
    • (2003) Am J Ophthalmol , vol.136 , pp. 26-33
    • Miglior, S.1    Guareschi, M.2    Albe, E.3
  • 3
    • 0031770658 scopus 로고    scopus 로고
    • Identification of early glaucoma cases with the scanning laser ophthalmoscope
    • Wollstein G, Garway-Heath DF, Hitchings RA. Identification of early glaucoma cases with the scanning laser ophthalmoscope. Ophthalmology. 1998;105:1557-1563.
    • (1998) Ophthalmology , vol.105 , pp. 1557-1563
    • Wollstein, G.1    Garway-Heath, D.F.2    Hitchings, R.A.3
  • 4
    • 0029081268 scopus 로고
    • Ability of the Heidelberg Retina Tomograph to detect early glaucomatous visual field loss
    • Mikelberg F, Parfitt C, Swindale N, others. Ability of the Heidelberg Retina Tomograph to detect early glaucomatous visual field loss. J Glaucoma 1995;4:242-247.
    • (1995) J Glaucoma , vol.4 , pp. 242-247
    • Mikelberg, F.1    Parfitt, C.2    Swindale, N.3
  • 5
    • 0030985497 scopus 로고    scopus 로고
    • The effect of optic disc size on diagnostic precision with the Heidelberg retina tomograph
    • Iester M, Mikelberg FS, Drance SM. The effect of optic disc size on diagnostic precision with the Heidelberg retina tomograph. Ophthalmology. 1997;104:545-548.
    • (1997) Ophthalmology , vol.104 , pp. 545-548
    • Iester, M.1    Mikelberg, F.S.2    Drance, S.M.3
  • 6
    • 0031979688 scopus 로고    scopus 로고
    • Detection of early glaucomatous structural damage with confocal scanning laser tomography
    • Bathija R, Zangwill L, Berry CC, et al. Detection of early glaucomatous structural damage with confocal scanning laser tomography. J Glaucoma. 1998;7:121-127.
    • (1998) J Glaucoma , vol.7 , pp. 121-127
    • Bathija, R.1    Zangwill, L.2    Berry, C.C.3
  • 7
    • 0038321468 scopus 로고    scopus 로고
    • Comparison of data analysis tools for detection of glaucoma with the Heidelberg Retina Tomograph
    • Ford BA, Artes PH, McCormick TA, et al. Comparison of data analysis tools for detection of glaucoma with the Heidelberg Retina Tomograph. Ophthalmology. 2003;110:1145-1150.
    • (2003) Ophthalmology , vol.110 , pp. 1145-1150
    • Ford, B.A.1    Artes, P.H.2    McCormick, T.A.3
  • 8
    • 2642572679 scopus 로고    scopus 로고
    • Optic nerve head morphometry in healthy adults using confocal laser scanning tomography
    • Hermann MM, Theofylaktopoulos I, Bangard N, et al. Optic nerve head morphometry in healthy adults using confocal laser scanning tomography. Br J Ophthalmol. 2004;88:761-765.
    • (2004) Br J Ophthalmol , vol.88 , pp. 761-765
    • Hermann, M.M.1    Theofylaktopoulos, I.2    Bangard, N.3
  • 9
    • 3142516397 scopus 로고    scopus 로고
    • Assessment of optic nerve head topographic parameters with a confocal scanning laser ophthalmoscope
    • Durukan AH, Yucel I, Akar Y, Bayraktar MZ, Assessment of optic nerve head topographic parameters with a confocal scanning laser ophthalmoscope. Clin Experiment Ophthalmol. 2004;32:259-264.
    • (2004) Clin Experiment Ophthalmol , vol.32 , pp. 259-264
    • Durukan, A.H.1    Yucel, I.2    Akar, Y.3    Bayraktar, M.Z.4
  • 10
    • 0033198873 scopus 로고    scopus 로고
    • Scanning laser tomography to evaluate optic discs of normal eyes
    • Nakamura H, Maeda T, Suzuki Y, Inoue Y. Scanning laser tomography to evaluate optic discs of normal eyes. Jpn J Ophthalmol. 1999;43:410-414.
    • (1999) Jpn J Ophthalmol , vol.43 , pp. 410-414
    • Nakamura, H.1    Maeda, T.2    Suzuki, Y.3    Inoue, Y.4
  • 11
    • 24644472060 scopus 로고    scopus 로고
    • Laser scanning tomography of the optic nerve head in a normal elderly population: The Bridlington Eye Assessment Project
    • Vernon S, Hawker M, Ainsworth G, et al. Laser scanning tomography of the optic nerve head in a normal elderly population: The Bridlington Eye Assessment Project. Invest Ophthalmol Vis Sci. 2005;46:2823-2828.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 2823-2828
    • Vernon, S.1    Hawker, M.2    Ainsworth, G.3
  • 12
    • 0036108625 scopus 로고    scopus 로고
    • Intraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg Retina Tomograph
    • Miglior S, Albe E, Guareschi M, et al. Intraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg Retina Tomograph. Ophthalmology. 2002;109:1072-1077.
    • (2002) Ophthalmology , vol.109 , pp. 1072-1077
    • Miglior, S.1    Albe, E.2    Guareschi, M.3
  • 13
    • 0032978904 scopus 로고    scopus 로고
    • Inter- and intraobserver variation in the analysis of optic disc images: Comparison of the Heidelberg retina tomograph and computer assisted planimetry
    • Garway-Heath DF, Poinoosawmy D, Wollstein G, et al. Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry. Br J Ophthalmol. 1999;83:664-669.
    • (1999) Br J Ophthalmol , vol.83 , pp. 664-669
    • Garway-Heath, D.F.1    Poinoosawmy, D.2    Wollstein, G.3
  • 14
    • 0033774779 scopus 로고    scopus 로고
    • Changing views on open-angle glaucoma: Definitions and prevalences. The Rotterdam Study
    • Wolfs RC, Borger PH, Ramrattan RS, et al. Changing views on open-angle glaucoma: definitions and prevalences. The Rotterdam Study. Invest Ophthalmol Vis Sci. 2000;41:3309-3321.
    • (2000) Invest Ophthalmol Vis Sci , vol.41 , pp. 3309-3321
    • Wolfs, R.C.1    Borger, P.H.2    Ramrattan, R.S.3
  • 15
    • 0018833092 scopus 로고
    • Prognostic significance of optic disk cupping in ocular hypertensive patients
    • Yablonski ME, Zimmerman TJ, Kass MA, Becker B. Prognostic significance of optic disk cupping in ocular hypertensive patients. Am J Ophthalmol. 1980;89:585-592.
    • (1980) Am J Ophthalmol , vol.89 , pp. 585-592
    • Yablonski, M.E.1    Zimmerman, T.J.2    Kass, M.A.3    Becker, B.4
  • 16
    • 2442523160 scopus 로고    scopus 로고
    • The use of RADAAR (ratio of rim area to disc area asymmetry) in detecting glaucoma and its severity
    • Harasymowycz P, Davis B, Xu G, et al. The use of RADAAR (ratio of rim area to disc area asymmetry) in detecting glaucoma and its severity. Can J Ophthalmol. 2004;39:240-244.
    • (2004) Can J Ophthalmol , vol.39 , pp. 240-244
    • Harasymowycz, P.1    Davis, B.2    Xu, G.3
  • 17
    • 3142579190 scopus 로고    scopus 로고
    • Confocal scanning laser ophthalmoscopy classifiers and stereophotograph evaluation for prediction of visual field abnormalities in glaucoma-suspect eyes
    • Bowd C, Zangwill LM, Medeiros FA, et al. Confocal scanning laser ophthalmoscopy classifiers and stereophotograph evaluation for prediction of visual field abnormalities in glaucoma-suspect eyes. Invest Ophthalmol Vis Sci. 2004;45:2255-2262.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 2255-2262
    • Bowd, C.1    Zangwill, L.M.2    Medeiros, F.A.3
  • 18
    • 0037357347 scopus 로고    scopus 로고
    • The normal optic nerve head on Heidelberg Retina Tomograph II
    • Agarwal HC, Gulati V, Sihota R. The normal optic nerve head on Heidelberg Retina Tomograph II. Indian J Ophthalmol. 2003;51:25-33.
    • (2003) Indian J Ophthalmol , vol.51 , pp. 25-33
    • Agarwal, H.C.1    Gulati, V.2    Sihota, R.3
  • 19
    • 0032471005 scopus 로고    scopus 로고
    • Descriptive information of topographic parameters computed at the optic nerve head with the Heidelberg retina tomograph
    • Saruhan A, Orgul S, Kocak I, et al. Descriptive information of topographic parameters computed at the optic nerve head with the Heidelberg retina tomograph. J Glaucoma. 1998;7:420-429.
    • (1998) J Glaucoma , vol.7 , pp. 420-429
    • Saruhan, A.1    Orgul, S.2    Kocak, I.3
  • 21
    • 0034442639 scopus 로고    scopus 로고
    • Influence of optic disc size on neuroretinal rim shape in healthy eyes
    • Budde WM, Jonas JB, Martus P, Grundler AE. Influence of optic disc size on neuroretinal rim shape in healthy eyes. J Glaucoma. 2000;9:357-362.
    • (2000) J Glaucoma , vol.9 , pp. 357-362
    • Budde, W.M.1    Jonas, J.B.2    Martus, P.3    Grundler, A.E.4
  • 22
    • 0036022742 scopus 로고    scopus 로고
    • Variables affecting test-retest variability of Heidelberg Retina Tomograph II stereometric parameters
    • Sihota R, Gulati V, Agarwal HC, et al. Variables affecting test-retest variability of Heidelberg Retina Tomograph II stereometric parameters. J Glaucoma. 2002;11:321-328.
    • (2002) J Glaucoma , vol.11 , pp. 321-328
    • Sihota, R.1    Gulati, V.2    Agarwal, H.C.3
  • 23
    • 0030789103 scopus 로고    scopus 로고
    • Effect of cataract and pupil size on image quality with confocal scanning laser ophthalmoscopy
    • Zangwill L, Irak I, Berry CC, et al. Effect of cataract and pupil size on image quality with confocal scanning laser ophthalmoscopy. Arch Ophthalmol. 1997;115:983-990.
    • (1997) Arch Ophthalmol , vol.115 , pp. 983-990
    • Zangwill, L.1    Irak, I.2    Berry, C.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.