메뉴 건너뛰기




Volumn 79, Issue 939, 2006, Pages 244-247

Margins between clinical target volume and planning target volume for electron beam therapy

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; ELECTRON THERAPY; GEOMETRY; LINEAR ACCELERATOR; MATHEMATICAL ANALYSIS; METHODOLOGY; NORMAL DISTRIBUTION; PHANTOM; PHOTON THERAPY; RADIATION FIELD; SYSTEMATIC ERROR; TARGET ORGAN;

EID: 33644682948     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/70202978     Document Type: Article
Times cited : (4)

References (9)
  • 1
    • 0003651542 scopus 로고
    • Prescribing, recording and reporting photon beam therapy
    • International Commission on Radiation Units and Measurements ICRU Report 50 Bethesda MD: ICRU
    • International Commission on Radiation Units and Measurements. ICRU Report 50. Prescribing, recording and reporting photon beam therapy. Bethesda MD: ICRU, 1993.
    • (1993)
  • 2
    • 0003418877 scopus 로고    scopus 로고
    • Prescribing, recording and reporting photon beam therapy
    • International Commission on Radiation Units and Measurements Bethesda MD: ICRU ICRU Report 62 (Supplement to ICRU report 50)
    • International Commission on Radiation Units and Measurements. ICRU Report 62 (Supplement to ICRU report 50). Prescribing, recording and reporting photon beam therapy. Bethesda MD: ICRU, 1999.
    • (1999)
  • 3
    • 0142106065 scopus 로고    scopus 로고
    • British Institute of Radiology Working Party London, UK: British Institute of Radiology
    • British Institute of Radiology Working Party. Geometric uncertainties in radiotherapy. London, UK: British Institute of Radiology, 2003.
    • (2003) Geometric Uncertainties in Radiotherapy
  • 4
    • 33644951724 scopus 로고    scopus 로고
    • Prescribing, recording and reporting electron beam therapy
    • International Commission on Radiation Units and Measurements Oxford University Press ICRU Report 71
    • International Commission on Radiation Units and Measurements. ICRU Report 71. Prescribing, recording and reporting electron beam therapy. Oxford University Press, 2004.
    • (2004)
  • 5
    • 0033041247 scopus 로고    scopus 로고
    • Inclusion of geometrical uncertainties in radiotherapy planning by means of coverage probability
    • Stroom JC, deBoer HC, Huizenga H, Visser AG. Inclusion of geometrical uncertainties in radiotherapy planning by means of coverage probability. Int J Radiat Oncol Biol Phys 1999;43:905-19.
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 905-919
    • Stroom, J.C.1    deBoer, H.C.2    Huizenga, H.3    Visser, A.G.4
  • 6
    • 33644940547 scopus 로고    scopus 로고
    • A novel way to allow for uncertainties in delineation and changes in shape of target volumes in radiotherapy
    • Chambers LA, Chambers IR, editors UK: Institute of Physics in Engineering and Medicine September 6-8 York, UK. York
    • McKenzie AL. A novel way to allow for uncertainties in delineation and changes in shape of target volumes in radiotherapy. In: Chambers LA, Chambers IR, editors. Proceedings of the 11th Annual Scientific Meeting; 2004 September 6-8; York, UK. York, UK: Institute of Physics in Engineering and Medicine, 2004.
    • (2004) Proceedings of the 11th Annual Scientific Meeting; 2004
    • McKenzie, A.L.1
  • 7
    • 0032767908 scopus 로고    scopus 로고
    • Relative electron density calibration of CT scanners for radiotherapy treatment planning
    • Thomas SJ. Relative electron density calibration of CT scanners for radiotherapy treatment planning. Br J Radiol 1999;72:781-6.
    • (1999) Br J Radiol , vol.72 , pp. 781-786
    • Thomas, S.J.1
  • 8
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • Van Herk M, Remeijer P, Rasch C, Lebesque JV. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 2000;47:1121-35.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 9
    • 0020973738 scopus 로고
    • Electron beam dose planning using Gaussian beams. Improved radial dose profiles
    • Lax I, Brahme A, Andreo P. Electron beam dose planning using Gaussian beams. Improved radial dose profiles. Acta Radiol Suppl 1983;364:49-59.
    • (1983) Acta Radiol Suppl , vol.364 , pp. 49-59
    • Lax, I.1    Brahme, A.2    Andreo, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.