메뉴 건너뛰기




Volumn 27, Issue 6, 2005, Pages 493-499

Comparison of proximal caries detection in primary teeth between laser fluorescence and bitewing radiography

Author keywords

Diagnodent; Laser fluorescence; Primary teeth; Proximal caries detection

Indexed keywords

DIAGNOSTIC AGENT;

EID: 33644676094     PISSN: 01641263     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (37)

References (35)
  • 1
    • 0014726737 scopus 로고
    • The relationship of deciduous enamel structure to dental disease
    • Mortimer KY. The relationship of deciduous enamel structure to dental disease. Caries Res 1970;4:206-223.
    • (1970) Caries Res , vol.4 , pp. 206-223
    • Mortimer, K.Y.1
  • 2
    • 0024355836 scopus 로고
    • Mineralization differences between human deciduous and permanent enamel measured by quantitative microradiography
    • Wilson PR, Beynon AD. Mineralization differences between human deciduous and permanent enamel measured by quantitative microradiography. Archs Oral Biol 1989;34:85-88.
    • (1989) Archs Oral Biol , vol.34 , pp. 85-88
    • Wilson, P.R.1    Beynon, A.D.2
  • 3
    • 0018272829 scopus 로고
    • The prevalence and progression of approximal caries in the deciduous dentition in British children
    • Murray JJ, Majid ZA. The prevalence and progression of approximal caries in the deciduous dentition in British children. Br Dent J 1978;145:161-164.
    • (1978) Br Dent J , vol.145 , pp. 161-164
    • Murray, J.J.1    Majid, Z.A.2
  • 4
    • 0026484068 scopus 로고
    • An in vivo comparison of radiographic and directly assessed clinical caries status of posterior approximal surfaces in primary and permanent teeth
    • Pitts NB, Rimmer PA. An in vivo comparison of radiographic and directly assessed clinical caries status of posterior approximal surfaces in primary and permanent teeth. Caries Res 1992;26:146-152.
    • (1992) Caries Res , vol.26 , pp. 146-152
    • Pitts, N.B.1    Rimmer, P.A.2
  • 5
    • 0016424426 scopus 로고
    • Concurrent validity of an epidemiological diagnostic system for caries with the histological appearance of extracted teeth as validating criterion
    • Downer MC. Concurrent validity of an epidemiological diagnostic system for caries with the histological appearance of extracted teeth as validating criterion. Caries Res 1975:9:231-246.
    • (1975) Caries Res , vol.9 , pp. 231-246
    • Downer, M.C.1
  • 6
    • 0027350903 scopus 로고
    • Validity and reproducibility of clinical examination, fibre-optic transillumination, and bitewing radiology for the diagnosis of small approximal carious lesions: An in vitro study
    • Peers A, Hill FJ, Mitropoulos CM, Holloway PJ. Validity and reproducibility of clinical examination, fibre-optic transillumination, and bitewing radiology for the diagnosis of small approximal carious lesions: An in vitro study. Caries Res 1993;27:307-311.
    • (1993) Caries Res , vol.27 , pp. 307-311
    • Peers, A.1    Hill, F.J.2    Mitropoulos, C.M.3    Holloway, P.J.4
  • 7
    • 0027351387 scopus 로고
    • Radiovisiographic diagnosis of dental caries: Initial comparison of basic mode videoprints with bitewing radiography
    • Russel M, Pitts NB. Radiovisiographic diagnosis of dental caries: Initial comparison of basic mode videoprints with bitewing radiography. Caries Res 1993;27:65-70.
    • (1993) Caries Res , vol.27 , pp. 65-70
    • Russel, M.1    Pitts, N.B.2
  • 8
    • 0031585749 scopus 로고    scopus 로고
    • An evaluation of the diagnostic yield from bitewing radiograps of small approximal and occlusal carious lesions in a low prevalence sample in vitro using different film types and speeds
    • Ricketts DNJ, Whaites EJ, Kidd EAM, Brown JE, Wilson RF. An evaluation of the diagnostic yield from bitewing radiograps of small approximal and occlusal carious lesions in a low prevalence sample in vitro using different film types and speeds. Br Dent J 1997;182:51-58.
    • (1997) Br Dent J , vol.182 , pp. 51-58
    • Ricketts, D.N.J.1    Whaites, E.J.2    Kidd, E.A.M.3    Brown, J.E.4    Wilson, R.F.5
  • 9
    • 0027639948 scopus 로고
    • Advances in methods for diagnosing coronal caries-a review
    • Angmar-Månsson B, ten Bosch JJ. Advances in methods for diagnosing coronal caries-a review. Adv Dent Res 1993;7:70-79.
    • (1993) Adv Dent Res , vol.7 , pp. 70-79
    • Angmar-Månsson, B.1    Ten Bosch, J.J.2
  • 10
    • 0038162434 scopus 로고    scopus 로고
    • Diagnosis of approximal caries: Bitewing radiology vs the ultrasound caries detector. An in vitro study
    • Matalon S, Feuerstein O, Kaffe I. Diagnosis of approximal caries: Bitewing radiology vs the ultrasound caries detector. An in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003;59: 626-631.
    • (2003) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.59 , pp. 626-631
    • Matalon, S.1    Feuerstein, O.2    Kaffe, I.3
  • 11
    • 0001272404 scopus 로고    scopus 로고
    • Development of a diode laser based fluorescence caries detector [abstract]
    • Hibst R, Gall R. Development of a diode laser based fluorescence caries detector [abstract]. Caries Res 1998;32:294.
    • (1998) Caries Res , vol.32 , pp. 294
    • Hibst, R.1    Gall, R.2
  • 12
    • 0033160413 scopus 로고    scopus 로고
    • Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro
    • Lussi A, Imwinkelried S, Pitts NB, Longbottom C, Reich E. Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro. Caries Res 1999;33:261-266.
    • (1999) Caries Res , vol.33 , pp. 261-266
    • Lussi, A.1    Imwinkelried, S.2    Pitts, N.B.3    Longbottom, C.4    Reich, E.5
  • 13
    • 0035219814 scopus 로고    scopus 로고
    • Comparison of QEF and DIAGNOdent for quantification of smooth surface caries
    • Shi X-Q, Tranaeus S, Angmar-Månsson B. Comparison of QEF and DIAGNOdent for quantification of smooth surface caries. Caries Res 2001;35:21-26.
    • (2001) Caries Res , vol.35 , pp. 21-26
    • Shi, X.-Q.1    Tranaeus, S.2    Angmar-Månsson, B.3
  • 14
    • 0035318853 scopus 로고    scopus 로고
    • Validation of DIAGNOdent for quantification of smooth-surface caries: An in vitro study
    • Shi X-Q, Tranaeus, S, Angmar-Månsson B. Validation of DIAGNOdent for quantification of smooth-surface caries: an in vitro study. Acta Odontol Scand 2001:59:74-78.
    • (2001) Acta Odontol Scand , vol.59 , pp. 74-78
    • Shi, X.-Q.1    Tranaeus, S.2    Angmar-Månsson, B.3
  • 15
    • 0034152651 scopus 로고    scopus 로고
    • Occlusal caries detection with KaVo DIAGNOdent and radiography: An in vitro comparison
    • Shi X-Q, Welander U, Angmar-Månsson B. Occlusal caries detection with KaVo DIAGNOdent and radiography: An in vitro comparison. Caries Res 2000;34: 151-158.
    • (2000) Caries Res , vol.34 , pp. 151-158
    • Shi, X.-Q.1    Welander, U.2    Angmar-Månsson, B.3
  • 16
    • 0035259929 scopus 로고    scopus 로고
    • Clinical performance of a laser fluorescence device for detection of occlusal caries lesions
    • Lussi A, Megert B, Longbottom C, Reich E, Francescut P. Clinical performance of a laser fluorescence device for detection of occlusal caries lesions. Eur J Oral Sci 2001;109:14-19.
    • (2001) Eur J Oral Sci , vol.109 , pp. 14-19
    • Lussi, A.1    Megert, B.2    Longbottom, C.3    Reich, E.4    Francescut, P.5
  • 17
    • 0035962477 scopus 로고    scopus 로고
    • Occlusal caries detection in primary teeth: A comparison of DIAGNOdent with conventional methods
    • Attrill DC, Ashley PF. Occlusal caries detection in primary teeth: A comparison of DIAGNOdent with conventional methods. Br Dent J 2001; 190:440-443.
    • (2001) Br Dent J , vol.190 , pp. 440-443
    • Attrill, D.C.1    Ashley, P.F.2
  • 18
    • 1342306392 scopus 로고    scopus 로고
    • Correlation between fissure discoloration, Diagnodent measurements, and caries depth: An in vitro study
    • Francescut P, Lussi A. Correlation between fissure discoloration, Diagnodent measurements, and caries depth: An in vitro study. Pediatr Dent 2003;25:559-564.
    • (2003) Pediatr Dent , vol.25 , pp. 559-564
    • Francescut, P.1    Lussi, A.2
  • 19
    • 33644663240 scopus 로고    scopus 로고
    • An in vitro comparison of a laser device with bitewing radiography for approximal caries detection [abstract]
    • Wagner M, Longbottom C, Pitts NB. An in vitro comparison of a laser device with bitewing radiography for approximal caries detection [abstract]. Caries Res 1999;33:298.
    • (1999) Caries Res , vol.33 , pp. 298
    • Wagner, M.1    Longbottom, C.2    Pitts, N.B.3
  • 20
    • 0344942660 scopus 로고
    • Simulated in vivo comparison of bitewing radiography and DIAGNOdent for approximal caries detection [abstract]
    • Longbottom C, Wagner M, Pitts NB, Lussi A. Simulated in vivo comparison of bitewing radiography and DIAGNOdent for approximal caries detection [abstract]. Caries Res 1992;33:298.
    • (1992) Caries Res , vol.33 , pp. 298
    • Longbottom, C.1    Wagner, M.2    Pitts, N.B.3    Lussi, A.4
  • 21
    • 33644678833 scopus 로고    scopus 로고
    • Laser fluorescence detection of approximal caries: Initial in vitro results [abstract]
    • Forgie AH, Pine CM, Pitts NB. Laser fluorescence detection of approximal caries: Initial in vitro results [abstract]. J Dent Res 1999;78:1044.
    • (1999) J Dent Res , vol.78 , pp. 1044
    • Forgie, A.H.1    Pine, C.M.2    Pitts, N.B.3
  • 22
    • 0038147051 scopus 로고    scopus 로고
    • In vitro study of caries detection through sound dentin using a laser fluorescence device, DIAGNOdent
    • Iwami Y, Shimizu A, Yamamoto H, Hayashi M, Takeshige F, Ebisu S. In vitro study of caries detection through sound dentin using a laser fluorescence device, DIAGNOdent. Eur J Oral Sci 2003;111:7-11.
    • (2003) Eur J Oral Sci , vol.111 , pp. 7-11
    • Iwami, Y.1    Shimizu, A.2    Yamamoto, H.3    Hayashi, M.4    Takeshige, F.5    Ebisu, S.6
  • 23
    • 0021417631 scopus 로고
    • Systems for grading approximal carious lesions and overlaps diagnosed from bitewing radiographs: Proposals for future standardization
    • Pitts NB. Systems for grading approximal carious lesions and overlaps diagnosed from bitewing radiographs: Proposals for future standardization. Community Dent Oral Epidemiol 1984; 12:114-122.
    • (1984) Community Dent Oral Epidemiol , vol.12 , pp. 114-122
    • Pitts, N.B.1
  • 24
    • 0033122364 scopus 로고    scopus 로고
    • The choice of gold standard for evaluating tests for caries diagnosis
    • Wenzel A, Hintze H. The choice of gold standard for evaluating tests for caries diagnosis. Dentomaxillofac Radiol 1999;28:132-136.
    • (1999) Dentomaxillofac Radiol , vol.28 , pp. 132-136
    • Wenzel, A.1    Hintze, H.2
  • 25
    • 0038193792 scopus 로고    scopus 로고
    • An in vitro comparison of a combined FOTI/visual examination of occlusal caries with other caries diagnostic methods and the effect of stain on their diagnostic performance
    • Cârtes DF, Ellwood RP, Ekstrand KR. An in vitro comparison of a combined FOTI/visual examination of occlusal caries with other caries diagnostic methods and the effect of stain on their diagnostic performance. Caries Res 2003;37:8-16.
    • (2003) Caries Res , vol.37 , pp. 8-16
    • Cârtes, D.F.1    Ellwood, R.P.2    Ekstrand, K.R.3
  • 26
    • 0036905961 scopus 로고    scopus 로고
    • Occlusal caries detection and quantification by DIAGNOdent and electronic caries monitor: In vitro comparison
    • Bamzahim M, Shi X-Q, Angmar-Månsson B. Occlusal caries detection and quantification by DIAGNOdent and electronic caries monitor: In vitro comparison. Acta Odontol Scand 2002;60:360-364.
    • (2002) Acta Odontol Scand , vol.60 , pp. 360-364
    • Bamzahim, M.1    Shi, X.-Q.2    Angmar-Månsson, B.3
  • 27
    • 0036580375 scopus 로고    scopus 로고
    • Reliability and validity issues of laser fluorescence measurements in occlusal caries diagnosis
    • Alwas-Danowska HM, Plasschaert AJ, Suliborski S, Verdonschot EH. Reliability and validity issues of laser fluorescence measurements in occlusal caries diagnosis. J Dent 2002;30:129-234.
    • (2002) J Dent , vol.30 , pp. 129-234
    • Alwas-Danowska, H.M.1    Plasschaert, A.J.2    Suliborski, S.3    Verdonschot, E.H.4
  • 28
    • 0037518397 scopus 로고    scopus 로고
    • Clinical study of the use of the laser fluorescence device DIAGNOdent for detection of occlusal caries in children
    • Anttonen V, Seppä L, Hausen H. Clinical study of the use of the laser fluorescence device DIAGNOdent for detection of occlusal caries in children. Caries Res 2003;37:17-23.
    • (2003) Caries Res , vol.37 , pp. 17-23
    • Anttonen, V.1    Seppä, L.2    Hausen, H.3
  • 29
  • 30
    • 0037518301 scopus 로고    scopus 로고
    • An in vitro study of the correlation between clinical and radiographic examinations of proximal carious lesions in primary molars
    • Feldens CA, Tovo MF, Kramer PF, Feldens EG, Ferreira SH, Finkler M. An in vitro study of the correlation between clinical and radiographic examinations of proximal carious lesions in primary molars. J Clin Pediatr Dent 2003;27:143-148.
    • (2003) J Clin Pediatr Dent , vol.27 , pp. 143-148
    • Feldens, C.A.1    Tovo, M.F.2    Kramer, P.F.3    Feldens, E.G.4    Ferreira, S.H.5    Finkler, M.6
  • 31
    • 0022617575 scopus 로고
    • Clinical and radiographic assessment of appoximal carious lesions
    • Espelid I, Tviet AB. Clinical and radiographic assessment of appoximal carious lesions. Acta Odontol Scand 1986;44:31-37.
    • (1986) Acta Odontol Scand , vol.44 , pp. 31-37
    • Espelid, I.1    Tviet, A.B.2
  • 32
    • 0037518391 scopus 로고    scopus 로고
    • Performance of conventional and new methods for the detection of occlusal caries in deciduous teeth
    • Lussi A, Francescut P. Performance of conventional and new methods for the detection of occlusal caries in deciduous teeth. Caries Res 2003;37:2-7.
    • (2003) Caries Res , vol.37 , pp. 2-7
    • Lussi, A.1    Francescut, P.2
  • 33
    • 0041792523 scopus 로고    scopus 로고
    • Variation in DIAGNOdent measurements of stained artificial caries lesions [abstract]
    • Welsh GA, Hall AF, Hannah AJ, Foye RH. Variation in DIAGNOdent measurements of stained artificial caries lesions [abstract]. Caries Res 2000;34:324.
    • (2000) Caries Res , vol.34 , pp. 324
    • Welsh, G.A.1    Hall, A.F.2    Hannah, A.J.3    Foye, R.H.4
  • 34
    • 0035460161 scopus 로고    scopus 로고
    • Evaluation of visual, explorer, and a laser device for detection of early occlusal caries
    • El-Housseiny AA, Jamjoum H. Evaluation of visual, explorer, and a laser device for detection of early occlusal caries. J Clin Pediatr Dent 2001;26:41-48.
    • (2001) J Clin Pediatr Dent , vol.26 , pp. 41-48
    • El-Housseiny, A.A.1    Jamjoum, H.2
  • 35
    • 4344587204 scopus 로고    scopus 로고
    • A follow-up study of the use of DIANOdent for monitoring fissure caries in children
    • Anttonen V, Seppä L, Hausen H. A follow-up study of the use of DIANOdent for monitoring fissure caries in children. Community Dent Oral Epidemiol 2004:32:312-318.
    • (2004) Community Dent Oral Epidemiol , vol.32 , pp. 312-318
    • Anttonen, V.1    Seppä, L.2    Hausen, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.