메뉴 건너뛰기




Volumn 46, Issue 10, 2005, Pages 1679-1686

Evaluation of accuracy in activity calculations for the conjugate view method from Monte Carlo simulated scintillation camera images using experimental data in an anthropomorphic phantom

Author keywords

Activity quantification; Conjugate view method; Monte Carlo simulations; Scintigraphy; Sestamibi

Indexed keywords

METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M; DIAGNOSTIC AGENT; RADIOPHARMACEUTICAL AGENT;

EID: 33644666356     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (36)

References (9)
  • 3
    • 0027958158 scopus 로고
    • Computerized three-dimensional segmented human anatomy
    • Zubal IG, Harrell CR. Computerized three-dimensional segmented human anatomy. Med Phys. 1994;21:299-302.
    • (1994) Med Phys , vol.21 , pp. 299-302
    • Zubal, I.G.1    Harrell, C.R.2
  • 4
    • 0031456349 scopus 로고    scopus 로고
    • A comparison of 60 Hz uniform magnetic and electric induction in the human body
    • Dawson TW, Caputa K, Stuchly MA. A comparison of 60 Hz uniform magnetic and electric induction in the human body. Phys Med Biol 1997;42:2319-2329.
    • (1997) Phys Med Biol , vol.42 , pp. 2319-2329
    • Dawson, T.W.1    Caputa, K.2    Stuchly, M.A.3
  • 5
    • 0034786342 scopus 로고    scopus 로고
    • Registration of emission and transmission whole-body scintillation camera images
    • Sjögreen K, Ljungberg M, Wingårdh K, Erlandsson K, Strand S-E. Registration of emission and transmission whole-body scintillation camera images. J Nucl Med. 2001;42:1563-1570.
    • (2001) J Nucl Med , vol.42 , pp. 1563-1570
    • Sjögreen, K.1    Ljungberg, M.2    Wingårdh, K.3    Erlandsson, K.4    Strand, S.-E.5
  • 6
    • 0024713937 scopus 로고
    • A Monte Carlo program simulating scintillation camera imaging
    • Ljungberg M, Strand S-E. A Monte Carlo program simulating scintillation camera imaging. Comput Methods Programs Biomed. 1989;29:257-272.
    • (1989) Comput Methods Programs Biomed , vol.29 , pp. 257-272
    • Ljungberg, M.1    Strand, S.-E.2
  • 7
    • 0026221904 scopus 로고
    • A practical method for position dependent Compton-scatter correction in single photon emission CT
    • Ogawa K, Harata H, Ichihara T, Kubo A, Hashimoto S. A practical method for position dependent Compton-scatter correction in single photon emission CT. IEEE Trans Med Imaging. 1991;10:408-412.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 408-412
    • Ogawa, K.1    Harata, H.2    Ichihara, T.3    Kubo, A.4    Hashimoto, S.5
  • 8
    • 0028469266 scopus 로고
    • Osiris: A medical image-manipulation system
    • Ligier Y, Ratib O, Logean M, Girard C. Osiris: a medical image-manipulation system. MD Comput. 1994;11:212-218.
    • (1994) MD Comput , vol.11 , pp. 212-218
    • Ligier, Y.1    Ratib, O.2    Logean, M.3    Girard, C.4
  • 9
    • 0032435802 scopus 로고    scopus 로고
    • Absolute organ activity estimated by five different methods of background correction
    • Buijs WCAM, Siegel JA, Boerman OC, Corstens EHM. Absolute organ activity estimated by five different methods of background correction. J Nucl Med. 1998;39:2167-2172.
    • (1998) J Nucl Med , vol.39 , pp. 2167-2172
    • Buijs, W.C.A.M.1    Siegel, J.A.2    Boerman, O.C.3    Corstens, E.H.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.