-
2
-
-
0031782483
-
Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, F-fluoro-2-deoxyglucose, the Patlak method, and an image derived input function
-
K. Chen, D. Bandy, E. Reiman, S. C. Huang, M. Lawson, D. Feng, L. Yun, and A. Palant, Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, F-fluoro-2-deoxyglucose, the Patlak method, and an image derived input function, J. Cereb. Blood Flow Metab., 18 (1998), pp. 716-723.
-
(1998)
J. Cereb. Blood Flow Metab.
, vol.18
, pp. 716-723
-
-
Chen, K.1
Bandy, D.2
Reiman, E.3
Huang, S.C.4
Lawson, M.5
Feng, D.6
Yun, L.7
Palant, A.8
-
3
-
-
0032034228
-
Generalized linear least squares method for fast generation of myocardial blood flow parametric images with N-13 ammonia PET
-
K. Chen, M. Lawson, E. Reiman, A. Cooper, D. Feng, S. C. Huang, D. Bandy, D. Ho, L. Yen, and A. Palant, Generalized linear least squares method for fast generation of myocardial blood flow parametric images with N-13 ammonia PET, IEEE Trans. Med. Imag., 17(2) (1998), pp. 236-243.
-
(1998)
IEEE Trans. Med. Imag.
, vol.17
, Issue.2
, pp. 236-243
-
-
Chen, K.1
Lawson, M.2
Reiman, E.3
Cooper, A.4
Feng, D.5
Huang, S.C.6
Bandy, D.7
Ho, D.8
Yen, L.9
Palant, A.10
-
4
-
-
0003951723
-
-
MPS-SIAM, Philadelphia, PA
-
A. R. Conn, N. I. M. Gould and P. L. Toint, Trust-Region Methods, MPS-SIAM, Philadelphia, PA, 2000.
-
(2000)
Trust-region Methods
-
-
Conn, A.R.1
Gould, N.I.M.2
Toint, P.L.3
-
5
-
-
4243434265
-
Parametric imaging algorithms for multicompartmental models dynamic studies with positron emission tomography
-
K. Uemura, N. A. Lassen, T. Jones, and I. Kanno (eds), Elsevier Science Publishers, Amsterdam, The Netherlands
-
D. Feng and D. Ho, Parametric imaging algorithms for multicompartmental models dynamic studies with positron emission tomography, in K. Uemura, N. A. Lassen, T. Jones, and I. Kanno (eds), Quantification of Brain Function: Tracer Kinetics and Image Analysis in Brain PET, Elsevier Science Publishers, Amsterdam, The Netherlands, 1993, pp. 127-137.
-
(1993)
Quantification of Brain Function: Tracer Kinetics and Image Analysis in Brain PET
, pp. 127-137
-
-
Feng, D.1
Ho, D.2
-
6
-
-
0029484122
-
An evaluation of the algorithms for determining local cerebral metabolic rates of glucose using positron emission tomography dynamic data
-
D. Feng, D. Ho, K. Chen, L. Wu, J. Wang, R. Liu, and S. Yeh, An evaluation of the algorithms for determining local cerebral metabolic rates of glucose using positron emission tomography dynamic data, IEEE Trans. Med. Imag., 14(4) (1994), pp. 697-710.
-
(1994)
IEEE Trans. Med. Imag.
, vol.14
, Issue.4
, pp. 697-710
-
-
Feng, D.1
Ho, D.2
Chen, K.3
Wu, L.4
Wang, J.5
Liu, R.6
Yeh, S.7
-
7
-
-
0027572378
-
Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography
-
D. Feng, S. C. Huang, and Z. Wang, Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography, Intern. J. Bio-Med. Comp., 32 (1993), pp. 95-110.
-
(1993)
Intern. J. Bio-med. Comp.
, vol.32
, pp. 95-110
-
-
Feng, D.1
Huang, S.C.2
Wang, Z.3
-
8
-
-
0030216228
-
An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation
-
D. Feng, S. C. Huang, Z. Wang, and D. Ho, An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation, IEEE Trans. Med. Imag., 15(4) (1996), pp. 512-518.
-
(1996)
IEEE Trans. Med. Imag.
, vol.15
, Issue.4
, pp. 512-518
-
-
Feng, D.1
Huang, S.C.2
Wang, Z.3
Ho, D.4
-
9
-
-
0027609849
-
A study on statistically reliable and computationally efficient algorithms for generating local cerebral blood flow parametric images with positron emission tomography
-
D. Feng, Z. Wang, and S. C. Huang, A study on statistically reliable and computationally efficient algorithms for generating local cerebral blood flow parametric images with positron emission tomography, IEEE Trans. Med. Imag., 12(2) (1993), pp. 182-188.
-
(1993)
IEEE Trans. Med. Imag.
, vol.12
, Issue.2
, pp. 182-188
-
-
Feng, D.1
Wang, Z.2
Huang, S.C.3
-
11
-
-
0004236492
-
-
The Johns Hopkins University Press, Baltimore, MD
-
G. H. Golub and C. F. Van Loan, Matrix Computations, 2nd edn, The Johns Hopkins University Press, Baltimore, MD, 1989.
-
(1989)
Matrix Computations, 2nd Edn
-
-
Golub, G.H.1
Van Loan, C.F.2
-
13
-
-
33644609078
-
-
Ph.D. thesis, Department of Mathematics and Statistics, Arizona State University, AZ
-
C. Negoita, Global kinetic imaging using dynamic positron emission tomography data, Ph.D. thesis, Department of Mathematics and Statistics, Arizona State University, AZ, 2003.
-
(2003)
Global Kinetic Imaging Using Dynamic Positron Emission Tomography Data
-
-
Negoita, C.1
-
15
-
-
0029874365
-
Diminished glucose transport and phosphorylation in Alzheimer's disease determined by dynamic FDG-PET
-
M. Piert, R. Koeppe, B. Giordani, S. Berent, and D. Kühl, Diminished glucose transport and phosphorylation in Alzheimer's disease determined by dynamic FDG-PET, J. Nuclear Med., 37 (1996), pp. 201-208.
-
(1996)
J. Nuclear Med.
, vol.37
, pp. 201-208
-
-
Piert, M.1
Koeppe, R.2
Giordani, B.3
Berent, S.4
Kühl, D.5
-
16
-
-
0032211362
-
Generalized linear least squares algorithm for non-uniformly sampled biomedical system identification with possible repeated eigenvalues
-
K. Wong and D. Feng, Generalized linear least squares algorithm for non-uniformly sampled biomedical system identification with possible repeated eigenvalues, Comp. Methods Prog. Biomed., 57 (1998), pp. 167-177.
-
(1998)
Comp. Methods Prog. Biomed.
, vol.57
, pp. 167-177
-
-
Wong, K.1
Feng, D.2
|