-
1
-
-
0020492479
-
Oxygen behind the mask
-
Oxygen behind the mask. Lancet 1982; 2(8309):1197-1198
-
(1982)
Lancet
, vol.2
, Issue.8309
, pp. 1197-1198
-
-
-
2
-
-
0021710225
-
A reassessment of the validity of the iso-shunt graph
-
Lawler PG, Nunn JF: A reassessment of the validity of the iso-shunt graph. Br J Anaesth 1984; 56(12):1325-1335
-
(1984)
Br J Anaesth
, vol.56
, Issue.12
, pp. 1325-1335
-
-
Lawler, P.G.1
Nunn, J.F.2
-
3
-
-
0035176918
-
Performance of standard and reservoir-type Hudson masks in pregnant and non-pregnant subjects
-
Morris E, Smith A, Kinsella S: Performance of standard and reservoir-type Hudson masks in pregnant and non-pregnant subjects. Int J Obstet Anesth 2001; 10:284-288
-
(2001)
Int J Obstet Anesth
, vol.10
, pp. 284-288
-
-
Morris, E.1
Smith, A.2
Kinsella, S.3
-
4
-
-
0023952369
-
Performance of the Hudson Multi-Vent oxygen mask
-
Hunter J, Olson LG: Performance of the Hudson Multi-Vent oxygen mask. Med J Aust 1988; 148(9):444-447
-
(1988)
Med J Aust
, vol.148
, Issue.9
, pp. 444-447
-
-
Hunter, J.1
Olson, L.G.2
-
5
-
-
0025899141
-
Shortcomings of using two jet nebulizers in tandem with an aerosol face mask for optimal oxygen therapy
-
Foust GN, Potter WA, Wilons MD, et al: Shortcomings of using two jet nebulizers in tandem with an aerosol face mask for optimal oxygen therapy. Chest 1991; 99(6):1346-1351
-
(1991)
Chest
, vol.99
, Issue.6
, pp. 1346-1351
-
-
Foust, G.N.1
Potter, W.A.2
Wilons, M.D.3
-
6
-
-
0016757909
-
Measurement of intratracheal oxygen concentrations during face mask administration of oxygen: A modification for improved control
-
Wexler HR, Aberman A, Scott AA, et al: Measurement of intratracheal oxygen concentrations during face mask administration of oxygen: A modification for improved control. Can Anaesth Soc J 1975; 22(4):417-431
-
(1975)
Can Anaesth Soc J
, vol.22
, Issue.4
, pp. 417-431
-
-
Wexler, H.R.1
Aberman, A.2
Scott, A.A.3
-
7
-
-
0026410285
-
Modification of an aerosol mask to provide high concentrations of oxygen in the inspired air: Comparison to a nonrebreathing mask
-
Chechani V, Scott G, Burnham B, et al: Modification of an aerosol mask to provide high concentrations of oxygen in the inspired air: Comparison to a nonrebreathing mask [see comments]. Chest 1991; 100(6):1582-1585
-
(1991)
Chest
, vol.100
, Issue.6
, pp. 1582-1585
-
-
Chechani, V.1
Scott, G.2
Burnham, B.3
-
8
-
-
0031908294
-
Evaluation of five oxygen delivery devices in spontaneously breathing subjects by oxygraphy
-
Waldau T, Larsen VH, Bonde J: Evaluation of five oxygen delivery devices in spontaneously breathing subjects by oxygraphy. Anaesthesia 1998; 53(3):256-263
-
(1998)
Anaesthesia
, vol.53
, Issue.3
, pp. 256-263
-
-
Waldau, T.1
Larsen, V.H.2
Bonde, J.3
-
9
-
-
0024595081
-
The oxygen delivery characteristics of the Hudson Oxyone face mask
-
Milross J, Young IH, Donnelly P: The oxygen delivery characteristics of the Hudson Oxyone face mask. Anaesth Intensive Care 1989; 17(2):180-184
-
(1989)
Anaesth Intensive Care
, vol.17
, Issue.2
, pp. 180-184
-
-
Milross, J.1
Young, I.H.2
Donnelly, P.3
-
10
-
-
0021250445
-
Performance of the large-reservoir oxygen mask (Ventimask)
-
Jones HA, Turner SL, Hughes JM: Performance of the large-reservoir oxygen mask (Ventimask). Lancet 1984; 1(8392):1427-1431
-
(1984)
Lancet
, vol.1
, Issue.8392
, pp. 1427-1431
-
-
Jones, H.A.1
Turner, S.L.2
Hughes, J.M.3
-
11
-
-
0016757908
-
Mathematical model to predict inspired oxygen concentration: Description and validation
-
Wexler HR, Levy H, Cooper JD, et al: Mathematical model to predict inspired oxygen concentration: Description and validation. Can Anaesth Soc J 1975; 22(4):410-416
-
(1975)
Can Anaesth Soc J
, vol.22
, Issue.4
, pp. 410-416
-
-
Wexler, H.R.1
Levy, H.2
Cooper, J.D.3
-
12
-
-
10644291722
-
Randomized, prospective trial of oxygen, continuous positive airway pressure, and bilevel positive airway pressure by face mask in acute cardiogenic pulmonary edema
-
Park M, Sangean MC, Volpe MS, et al: Randomized, prospective trial of oxygen, continuous positive airway pressure, and bilevel positive airway pressure by face mask in acute cardiogenic pulmonary edema. Crit Care Med 2004; 32(12):2407-2415
-
(2004)
Crit Care Med
, vol.32
, Issue.12
, pp. 2407-2415
-
-
Park, M.1
Sangean, M.C.2
Volpe, M.S.3
-
13
-
-
0017196294
-
Continuous positive airway pressure without tracheal intubation in spontaneously breathing patients
-
Greenbaum DM, Millen JE, Eross B, et al: Continuous positive airway pressure without tracheal intubation in spontaneously breathing patients. Chest 1976; 69(5):615-620
-
(1976)
Chest
, vol.69
, Issue.5
, pp. 615-620
-
-
Greenbaum, D.M.1
Millen, J.E.2
Eross, B.3
-
14
-
-
0038324081
-
Intensive care in a field hospital in an urban disaster area: Lessons from the August 1999 earthquake in Turkey
-
Halpern P, Rosen B, Carasso S, et al: Intensive care in a field hospital in an urban disaster area: Lessons from the August 1999 earthquake in Turkey. Crit Care Med 2003; 31(5):1410-1414
-
(2003)
Crit Care Med
, vol.31
, Issue.5
, pp. 1410-1414
-
-
Halpern, P.1
Rosen, B.2
Carasso, S.3
-
15
-
-
0035901085
-
Controlled oxygen therapy and carbon dioxide retention during exacerbations of chronic obstructive pulmonary disease
-
Moloney ED, Kiely JL, McNicholas WT: Controlled oxygen therapy and carbon dioxide retention during exacerbations of chronic obstructive pulmonary disease. Lancet 2001; 357(9255):526-528
-
(2001)
Lancet
, vol.357
, Issue.9255
, pp. 526-528
-
-
Moloney, E.D.1
Kiely, J.L.2
McNicholas, W.T.3
-
16
-
-
0001898988
-
A method of controlled oxygen administration which reduces the risk of carbon-dioxide retention
-
Campbell EJ: A method of controlled oxygen administration which reduces the risk of carbon-dioxide retention. Lancet 1960; 2:12-14
-
(1960)
Lancet
, vol.2
, pp. 12-14
-
-
Campbell, E.J.1
-
17
-
-
0017936476
-
Oxygen concentrations received from commonly used delivery systems
-
Redding JS, McAfee DD, Gross CW: Oxygen concentrations received from commonly used delivery systems. South Med J 1978; 71(2):169-172
-
(1978)
South Med J
, vol.71
, Issue.2
, pp. 169-172
-
-
Redding, J.S.1
McAfee, D.D.2
Gross, C.W.3
-
18
-
-
0344442309
-
Severe acute respiratory distress syndrome (SARS): A critical care perspective
-
Manocha S, Walley KR, Russell JA: Severe acute respiratory distress syndrome (SARS): A critical care perspective. Crit Care Med 2003; 31(11):2684-2692
-
(2003)
Crit Care Med
, vol.31
, Issue.11
, pp. 2684-2692
-
-
Manocha, S.1
Walley, K.R.2
Russell, J.A.3
-
19
-
-
12244291005
-
Severe acute respiratory syndrome and critical care medicine: The Toronto experience
-
Booth CM, Stewart TE: Severe acute respiratory syndrome and critical care medicine: The Toronto experience. Crit Care Med 2005; 33(1 Suppl):S53-S60
-
(2005)
Crit Care Med
, vol.33
, Issue.1 SUPPL.
-
-
Booth, C.M.1
Stewart, T.E.2
-
20
-
-
1642290861
-
Dispersal of respiratory droplets with open vs closed oxygen delivery masks: Implications for the transmission of severe acute respiratory syndrome
-
Somogyi R, Vesely AE, Azami T, et al: Dispersal of respiratory droplets with open vs closed oxygen delivery masks: Implications for the transmission of severe acute respiratory syndrome. Chest 2004; 125(3):1155-1157
-
(2004)
Chest
, vol.125
, Issue.3
, pp. 1155-1157
-
-
Somogyi, R.1
Vesely, A.E.2
Azami, T.3
-
21
-
-
0029825989
-
Effect of different levels of hyperoxia on breathing in healthy subjects
-
Becker HF, Polo O, McNamara SG, et al: Effect of different levels of hyperoxia on breathing in healthy subjects. J Appl Physiol 1996; 81(4):1683-1690
-
(1996)
J Appl Physiol
, vol.81
, Issue.4
, pp. 1683-1690
-
-
Becker, H.F.1
Polo, O.2
McNamara, S.G.3
-
22
-
-
84930301972
-
Oxygen toxicity: Effects in man of oxygen inhalation at 1 and 3.5 atmospheres upon blood gas transport, cerebral circulation and cerebral metabolism
-
Lambertsen CJ, Dough RH, Cooper DY, et al: Oxygen toxicity: Effects in man of oxygen inhalation at 1 and 3.5 atmospheres upon blood gas transport, cerebral circulation and cerebral metabolism. J Appl Physiol 1953; 5:471-486
-
(1953)
J Appl Physiol
, vol.5
, pp. 471-486
-
-
Lambertsen, C.J.1
Dough, R.H.2
Cooper, D.Y.3
|