메뉴 건너뛰기




Volumn 45, Issue 2, 2006, Pages 65-69

Syndesmosis fixation: Analysis of shear stress via axial load on 3.5-mm and 4.5-mm quadricortical syndesmotic screws

Author keywords

Distal tibiofibular ligaments; Syndesmosis; Syndesmotic fixation

Indexed keywords

STAINLESS STEEL;

EID: 33644526946     PISSN: 10672516     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.jfas.2005.12.004     Document Type: Article
Times cited : (70)

References (23)
  • 1
    • 84873760557 scopus 로고
    • Fractures of the ankle. II. Combined radiographic and experimental-roentgenologic investigations
    • N. Lauge-Hansen Fractures of the ankle. II. Combined radiographic and experimental-roentgenologic investigations Arch Surg 60 1985 957 985
    • (1985) Arch Surg , vol.60 , pp. 957-985
    • Lauge-Hansen, N.1
  • 2
    • 18144449645 scopus 로고    scopus 로고
    • Syndesmosis injuries: Acute, chronic, new techniques for failed management
    • S. Mosier-LaClair, H. Pike, G. Pomeroy Syndesmosis injuries acute, chronic, new techniques for failed management Foot Ankle Clin 7 2002 551 565
    • (2002) Foot Ankle Clin , vol.7 , pp. 551-565
    • Mosier-Laclair, S.1    Pike, H.2    Pomeroy, G.3
  • 3
    • 0031595856 scopus 로고    scopus 로고
    • A biomechanical analysis of the squeeze test for sprains of the syndesmotic ligaments
    • C. Teitz, R. Harrington A biomechanical analysis of the squeeze test for sprains of the syndesmotic ligaments Foot Ankle Int 19 1996 489 492
    • (1996) Foot Ankle Int , vol.19 , pp. 489-492
    • Teitz, C.1    Harrington, R.2
  • 4
    • 0036770035 scopus 로고    scopus 로고
    • Syndesmosis injuries in athletes
    • T. Clanton, P. Paul Syndesmosis injuries in athletes Foot Ankle Clin 7 2002 529 549
    • (2002) Foot Ankle Clin , vol.7 , pp. 529-549
    • Clanton, T.1    Paul, P.2
  • 7
    • 0035067152 scopus 로고    scopus 로고
    • Overtightening of the ankle syndesmosis: Is it really possible?
    • P. Tornetta, J. Spoo, F. Reynolds, L. Cassandra Overtightening of the ankle syndesmosis is it really possible? J Bone Joint Surg 83A 2001 489 492
    • (2001) J Bone Joint Surg , vol.83 , pp. 489-492
    • Tornetta, P.1    Spoo, J.2    Reynolds, F.3    Cassandra, L.4
  • 9
    • 0022336853 scopus 로고
    • The effect of the syndesmotic screw on the extension capacity of the ankle joint
    • C. Olerud The effect of the syndesmotic screw on the extension capacity of the ankle joint Arch Orthop Trauma Surg 104 1985 299 302
    • (1985) Arch Orthop Trauma Surg , vol.104 , pp. 299-302
    • Olerud, C.1
  • 12
    • 0027374275 scopus 로고
    • Malleolar fractures with ankle joint instability-experience with the positioning screw
    • D. Heim, U. Heim, P. Regazzoni Malleolar fractures with ankle joint instability-experience with the positioning screw Unfallchirurgie 19 1993 307 312
    • (1993) Unfallchirurgie , vol.19 , pp. 307-312
    • Heim, D.1    Heim, U.2    Regazzoni, P.3
  • 13
    • 33644548451 scopus 로고
    • Results of operative treatment of displaced external rotation-abduction fractures of the ankle
    • L. de Souza, R. Gustilo, T. Meyer Results of operative treatment of displaced external rotation-abduction fractures of the ankle J Bone Joint Surg 71A 1989 23 27
    • (1989) J Bone Joint Surg , vol.71 , pp. 23-27
    • De Souza, L.1    Gustilo, R.2    Meyer, T.3
  • 14
    • 4043151571 scopus 로고    scopus 로고
    • Tricortical versus quadricortical syndesmosis fixation in ankle fractures: A prospective, randomized study comparing two methods of syndesmosis fixation
    • P. Hoiness, K. Stromsoe Tricortical versus quadricortical syndesmosis fixation in ankle fractures a prospective, randomized study comparing two methods of syndesmosis fixation J Orthop Trauma 18 2004 331 337
    • (2004) J Orthop Trauma , vol.18 , pp. 331-337
    • Hoiness, P.1    Stromsoe, K.2
  • 15
    • 0028263775 scopus 로고
    • Removal of broken syndesmotic screws: A technical tip
    • M. Henley, M. Law, S. Henry Removal of broken syndesmotic screws a technical tip Orthopedics 12 1994 643 644
    • (1994) Orthopedics , vol.12 , pp. 643-644
    • Henley, M.1    Law, M.2    Henry, S.3
  • 16
    • 0000055486 scopus 로고    scopus 로고
    • Injuries to the distal lower extremity syndesmosis
    • T. Wuest Injuries to the distal lower extremity syndesmosis J Am Acad Orthop Surg 5 1997 172 181
    • (1997) J Am Acad Orthop Surg , vol.5 , pp. 172-181
    • Wuest, T.1
  • 17
    • 0030845399 scopus 로고    scopus 로고
    • Ankle fractures involving the fibula proximal to the distal tibiofibular syndesmosis
    • N. Ebraheim, A. Mekhail, S. Gargasz Ankle fractures involving the fibula proximal to the distal tibiofibular syndesmosis Foot Ankle Int 18 1997 513 521
    • (1997) Foot Ankle Int , vol.18 , pp. 513-521
    • Ebraheim, N.1    Mekhail, A.2    Gargasz, S.3
  • 18
    • 0024406667 scopus 로고
    • Effect of the syndesmotic screw on ankle motion
    • R. Needleman, D. Skrade, J. Stiehl Effect of the syndesmotic screw on ankle motion Foot Ankle 10 1989 17 24
    • (1989) Foot Ankle , vol.10 , pp. 17-24
    • Needleman, R.1    Skrade, D.2    Stiehl, J.3
  • 19
    • 0036677219 scopus 로고    scopus 로고
    • Ruptured tibio-fibular syndesmosis: Comparison study of metallic to bioabsorbable fixation
    • I. Sinisaari, P. Luthje, R. Mikkonen Ruptured tibio-fibular syndesmosis comparison study of metallic to bioabsorbable fixation Foot Ankle Int 23 2002 744 748
    • (2002) Foot Ankle Int , vol.23 , pp. 744-748
    • Sinisaari, I.1    Luthje, P.2    Mikkonen, R.3
  • 20
    • 14644388861 scopus 로고    scopus 로고
    • Distal tibiofibular syndesmosis fixation: A cadaveric, simulated fracture stabilization study comparing bioabsorbable and metallic single screw fixation
    • S. Cox, D. Mukherjee, A. Ogden, R. Mayeux, K. Sadasivan, J. Albright, W. Pietrzak Distal tibiofibular syndesmosis fixation a cadaveric, simulated fracture stabilization study comparing bioabsorbable and metallic single screw fixation J Foot Ankle Surg 44 2005 144 151
    • (2005) J Foot Ankle Surg , vol.44 , pp. 144-151
    • Cox, S.1    Mukherjee, D.2    Ogden, A.3    Mayeux, R.4    Sadasivan, K.5    Albright, J.6    Pietrzak, W.7
  • 21
    • 0033623160 scopus 로고    scopus 로고
    • Biomechanical comparison of syndesmosis fixation with 3.5 and 4.5 millimeter stainless steel screws
    • M. Thompson, D. Gesnik Biomechanical comparison of syndesmosis fixation with 3.5 and 4.5 millimeter stainless steel screws Foot Ankle Int 21 2000 736 741
    • (2000) Foot Ankle Int , vol.21 , pp. 736-741
    • Thompson, M.1    Gesnik, D.2
  • 23
    • 0031940048 scopus 로고    scopus 로고
    • Can synthetic bone models approximate the mechanical properties of cadaveric first metatarsal bone
    • A. Landsman, T. Chang Can synthetic bone models approximate the mechanical properties of cadaveric first metatarsal bone J Foot Ankle Surg 37 1998 122 127
    • (1998) J Foot Ankle Surg , vol.37 , pp. 122-127
    • Landsman, A.1    Chang, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.