메뉴 건너뛰기




Volumn 102, Issue 3, 2006, Pages 690-693

Vasotrac® arterial blood pressure and direct arterial blood pressure monitoring during liver transplantation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTERY CATHETER; ARTICLE; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CLINICAL ARTICLE; CORRELATION ANALYSIS; FEMALE; HUMAN; LIVER TRANSPLANTATION; MALE; MONITOR; ORGAN TRANSPLANTATION; PRIORITY JOURNAL; BLOOD PRESSURE; COMPARATIVE STUDY; INSTRUMENTATION; MIDDLE AGED; PATIENT MONITORING; PHYSIOLOGY; PRESSURE TRANSDUCER; STANDARD;

EID: 33644513732     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ane.0000196512.96019.e4     Document Type: Article
Times cited : (23)

References (8)
  • 1
    • 0345425649 scopus 로고    scopus 로고
    • A new non-invasive method to measure blood pressure
    • Belani KG, Ozaki M, Hynson J, et al. A new non-invasive method to measure blood pressure. Anesthesiology 1999;91:686-92.
    • (1999) Anesthesiology , vol.91 , pp. 686-692
    • Belani, K.G.1    Ozaki, M.2    Hynson, J.3
  • 2
    • 0032971217 scopus 로고    scopus 로고
    • Accuracy of radial artery blood pressure determination with the Vasotrac
    • Belani KG, Buckley JJ, Poliac MO. Accuracy of radial artery blood pressure determination with the Vasotrac. Can J Anesth 1999;46:488-96.
    • (1999) Can J Anesth , vol.46 , pp. 488-496
    • Belani, K.G.1    Buckley, J.J.2    Poliac, M.O.3
  • 3
    • 17744374630 scopus 로고    scopus 로고
    • A comparison of the Vasotrac with invasive arterial blood pressure monitoring in children after pediatric cardiac surgery
    • Cua C, Thomas K, Zurakowski D, Laussen P. A comparison of the Vasotrac with invasive arterial blood pressure monitoring in children after pediatric cardiac surgery. Anesth Analg 2005;100:1289-94.
    • (2005) Anesth Analg , vol.100 , pp. 1289-1294
    • Cua, C.1    Thomas, K.2    Zurakowski, D.3    Laussen, P.4
  • 4
    • 0038650841 scopus 로고    scopus 로고
    • Intraoperative resource utilization in anesthesia for liver transplantation in the United States
    • Schumann R. Intraoperative resource utilization in anesthesia for liver transplantation in the United States. Anesth Analg 2003;97:21-8.
    • (2003) Anesth Analg , vol.97 , pp. 21-28
    • Schumann, R.1
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 0027218269 scopus 로고
    • The British Hypertension Society protocol for the evaluation of blood pressure measuring devices
    • O'Brien F, Petrie J, Littler W, et al. The British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertension 1993;11:S43-63.
    • (1993) J Hypertension , vol.11
    • O'Brien, F.1    Petrie, J.2    Littler, W.3
  • 8
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European Society of Hypertension
    • O'Brien E, Waeber B, Parati G, et al. Blood pressure measuring devices: recommendations of the European Society of Hypertension. Br Med J 2001;322:531-6.
    • (2001) Br Med J , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.