메뉴 건너뛰기




Volumn 28, Issue SUPPL. 1, 2004, Pages

Radiation exposure and projected risks with multidetector-row computed tomography scanning: Clinical strategies and technologic developments for dose reduction

Author keywords

Multidetector CT; Radiation dose reduction

Indexed keywords

DOSIMETRY; MULTIDETECTOR COMPUTED TOMOGRAPHY;

EID: 3342998322     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rct.0000120856.80935.f4     Document Type: Conference Paper
Times cited : (46)

References (26)
  • 2
    • 0042845953 scopus 로고    scopus 로고
    • National Conference on Dose Reduction in CT, with an emphasis on pediatric patients
    • Linton OW, Mettler FA. National Conference on Dose Reduction in CT, with an emphasis on pediatric patients. AJR Am J Roentgenol. 2003;181:321-329.
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 321-329
    • Linton, O.W.1    Mettler, F.A.2
  • 3
    • 3342968254 scopus 로고    scopus 로고
    • Emerging developments in multidetector CT
    • Washington, DC, September 13-14
    • Fox SH. Emerging developments in multidetector CT. Presented at the Advances in Multidetector CT Meeting, Washington, DC, September 13-14, 2003.
    • (2003) Advances in Multidetector CT Meeting
    • Fox, S.H.1
  • 4
    • 3343021468 scopus 로고    scopus 로고
    • CT radiation dose optimization in children
    • Washington, DC, September 13-14
    • Frush DP. CT radiation dose optimization in children. Presented at the Advances in multidetector CT Meeting, Washington, DC, September 13-14, 2003.
    • (2003) Advances in Multidetector CT Meeting
    • Frush, D.P.1
  • 5
    • 0027527540 scopus 로고
    • Use of radiology in U.S. general short-term hospitals: 1980-1990
    • Mettler FA, Briggs JA, Carchman R, et al. Use of radiology in U.S. general short-term hospitals: 1980-1990. Radiology. 1993;189:377-380.
    • (1993) Radiology , vol.189 , pp. 377-380
    • Mettler, F.A.1    Briggs, J.A.2    Carchman, R.3
  • 6
    • 0038080156 scopus 로고    scopus 로고
    • Effective doses in standard protocols for multi-slice CT scanning
    • Cohnen M, Poll LJ, Puettmann C, et al. Effective doses in standard protocols for multi-slice CT scanning. Eur Radiol. 2003;13:1148-1153.
    • (2003) Eur Radiol , vol.13 , pp. 1148-1153
    • Cohnen, M.1    Poll, L.J.2    Puettmann, C.3
  • 7
    • 0025348196 scopus 로고
    • The 1986 and 1988 UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) reports: Findings and implications
    • Mettler FA, Sinclair WK, Anspaugh L, et al. The 1986 and 1988 UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) reports: findings and implications. Health Phys. 1990;58:241-250.
    • (1990) Health Phys , vol.58 , pp. 241-250
    • Mettler, F.A.1    Sinclair, W.K.2    Anspaugh, L.3
  • 8
    • 1342266221 scopus 로고    scopus 로고
    • Strategies for CT radiation dose optimization
    • In press
    • Kalra MK, Maher MM, Thomas L, et al. Strategies for CT radiation dose optimization. Radiology. (In press).
    • Radiology
    • Kalra, M.K.1    Maher, M.M.2    Thomas, L.3
  • 9
    • 0029644266 scopus 로고
    • Effects of radiation on man
    • Meyniel G. Effects of radiation on man. Rev Prat. 1995;45:15-18.
    • (1995) Rev Prat , vol.45 , pp. 15-18
    • Meyniel, G.1
  • 11
    • 3342942212 scopus 로고    scopus 로고
    • The study of low dose radiation inducing hormesis effect on hematopoietic system
    • Wang G, Tan Y, Zhang F, et al. The study of low dose radiation inducing hormesis effect on hematopoietic system. Zhonghua Xue Ye Xue Za Zhi. 2001;22:232-234.
    • (2001) Zhonghua Xue Ye Xue Za Zhi , vol.22 , pp. 232-234
    • Wang, G.1    Tan, Y.2    Zhang, F.3
  • 12
    • 0034920719 scopus 로고    scopus 로고
    • 100 Years of observation on British radiologists: Mortality from cancer and other causes. 1897-1997
    • Berrington A, Darby SC, Weiss HA, et al. 100 years of observation on British radiologists: mortality from cancer and other causes. 1897-1997. Br J Radiol. 2001;74:507-519.
    • (2001) Br J Radiol , vol.74 , pp. 507-519
    • Berrington, A.1    Darby, S.C.2    Weiss, H.A.3
  • 13
    • 0033864575 scopus 로고    scopus 로고
    • Radiation-related cancer risks at low doses among atomic bomb survivors
    • Pierce DA, Preston DL. Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res. 2000;154:178-186.
    • (2000) Radiat Res , vol.154 , pp. 178-186
    • Pierce, D.A.1    Preston, D.L.2
  • 14
    • 0036939135 scopus 로고    scopus 로고
    • ALARA conference proceedings. The ALARA concept in pediatric CT: Intelligent dose reduction
    • Slovis TL. ALARA conference proceedings. The ALARA concept in pediatric CT: intelligent dose reduction. Pediatr Radiol. 2002;32:217-218.
    • (2002) Pediatr Radiol , vol.32 , pp. 217-218
    • Slovis, T.L.1
  • 15
    • 0036938794 scopus 로고    scopus 로고
    • Pediatric CT: Practical approach to diminish the radiation dose
    • Frush DP. Pediatric CT: practical approach to diminish the radiation dose. Pediatr Radiol. 2002;32:714-717.
    • (2002) Pediatr Radiol , vol.32 , pp. 714-717
    • Frush, D.P.1
  • 16
    • 0036176707 scopus 로고    scopus 로고
    • Improved pediatric multidetector body CT using a size-based color-coded format
    • Frush DP, Soden B, Frush KS, et al. Improved pediatric multidetector body CT using a size-based color-coded format. AJR Am J Roentgenol. 2002;178:721-726.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 721-726
    • Frush, D.P.1    Soden, B.2    Frush, K.S.3
  • 17
    • 0036839121 scopus 로고    scopus 로고
    • Clinical comparison between standard dose and 50% reduced dose abdominal CT: Effect on image quality
    • Kalra MK, Prasad S, Saini S, et al. Clinical comparison between standard dose and 50% reduced dose abdominal CT: effect on image quality. AJR Am J Roentgenol. 2002;179:1101-1106.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1101-1106
    • Kalra, M.K.1    Prasad, S.2    Saini, S.3
  • 18
    • 3342983649 scopus 로고    scopus 로고
    • Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT
    • In press
    • Kalra MK, Maher MM, Toth TL, et al. Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT. Korean J Radiology. (In press).
    • Korean J Radiology
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 19
    • 0037305308 scopus 로고    scopus 로고
    • Low-dose unenhanced multidetector CT of patients with suspected renal colic
    • Tack D, Sourtzis S, Delpierre I, et al. Low-dose unenhanced multidetector CT of patients with suspected renal colic. AJR Am Roentgenol. 2003;180: 305-311.
    • (2003) AJR Am Roentgenol , vol.180 , pp. 305-311
    • Tack, D.1    Sourtzis, S.2    Delpierre, I.3
  • 21
    • 3342949066 scopus 로고    scopus 로고
    • Multidetector CT scanning of abdomen and pelvis: A study for optimization of automatic tube current modulation technique in 120 subjects
    • In press
    • Kalra MK, Maher MM, Toth TL, et al. Multidetector CT scanning of abdomen and pelvis: a study for optimization of automatic tube current modulation technique in 120 subjects [abstract]. RSNA 2003. (In press))
    • (2003) RSNA
    • Kalra, M.K.1    Maher, M.M.2    Toth, T.L.3
  • 22
    • 1642453582 scopus 로고    scopus 로고
    • Application of rational practice and technical advances for optimizing radiation dose for chest CT
    • Maher MM, Kalra MK, et al. Application of rational practice and technical advances for optimizing radiation dose for chest CT. J Thorac Imaging. 2004;4:16-23.
    • (2004) J Thorac Imaging , vol.4 , pp. 16-23
    • Maher, M.M.1    Kalra, M.K.2
  • 23
    • 0037600583 scopus 로고    scopus 로고
    • Can noise reduction filters improve the quality of low radiation dose chest CT images?
    • Kalra MK, Wittram C, Maher MM, et al. Can noise reduction filters improve the quality of low radiation dose chest CT images? Radiology. 2003;228:251-256.
    • (2003) Radiology , vol.228 , pp. 251-256
    • Kalra, M.K.1    Wittram, C.2    Maher, M.M.3
  • 24
    • 0037600566 scopus 로고    scopus 로고
    • Low-dose abdominal CT: A blinded, randomized evaluation of image improvement from noise reduction filters
    • Kalra MK, Maher MM, Sahani DV, et al. Low-dose abdominal CT: a blinded, randomized evaluation of image improvement from noise reduction filters. Radiology. 2003;228:257-264.
    • (2003) Radiology , vol.228 , pp. 257-264
    • Kalra, M.K.1    Maher, M.M.2    Sahani, D.V.3
  • 25
    • 3342970018 scopus 로고    scopus 로고
    • Does low dose abdominal-pelvic CT compromise the lesion detection and morphological appearance?
    • Kalra MK, Blake MA, Maher MM, et al. Does low dose abdominal-pelvic CT compromise the lesion detection and morphological appearance? AJR Am J Roentgenol. 2003;180(Suppl):8.
    • (2003) AJR Am J Roentgenol , vol.180 , Issue.SUPPL. , pp. 8
    • Kalra, M.K.1    Blake, M.A.2    Maher, M.M.3
  • 26
    • 0043033136 scopus 로고    scopus 로고
    • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose)
    • Greess H, Nomayr A, Wolf H, et al. Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose). Eur Radiol. 2002;12:1571-1576.
    • (2002) Eur Radiol , vol.12 , pp. 1571-1576
    • Greess, H.1    Nomayr, A.2    Wolf, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.