메뉴 건너뛰기




Volumn 51, Issue 3 II, 2004, Pages 673-676

Correction for emission contamination in transmission scans for the high resolution research tomograph

Author keywords

High Resolution Research Tomograph (HRRT); PET; Reconstruction; Transmission

Indexed keywords

EMISSION CONTAMINATION (EC); HIGH RESOLUTION RESEARCH TOMOGRAPH (HRRT); HISTOGRAM-BASED SCALING; TRANSMISSION RECONSTRUCTION;

EID: 3342921912     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2004.829592     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 0242585503 scopus 로고    scopus 로고
    • Characterization of a single LSO crystal layer high resolution research tomograph
    • Boellaard et al., "Characterization of a single LSO crystal layer high resolution research tomograph," Phys. Med. Biol., pp. 429-449, 2003.
    • (2003) Phys. Med. Biol. , pp. 429-449
    • Boellaard1
  • 2
    • 3342925756 scopus 로고    scopus 로고
    • Accuracy of post-injection transmission scanning in myocardial FDG-PET studies using both filtered backprojection and iterative reconstruction
    • to be published
    • Van der Weerdt et al., "Accuracy of post-injection transmission scanning in myocardial FDG-PET studies using both filtered backprojection and iterative reconstruction," J. Nucl. Med., 2003, to be published.
    • (2003) J. Nucl. Med.
    • Van Der Weerdt1
  • 3
    • 11844296599 scopus 로고    scopus 로고
    • Clinical evaluation of processing techniques for attenuation correction with 137-Cs in whole body PET imaging
    • Benard et al., "Clinical evaluation of processing techniques for attenuation correction with 137-Cs in whole body PET imaging," J. Nucl. Med., pp. 1257-1263, 1999.
    • (1999) J. Nucl. Med. , pp. 1257-1263
    • Benard1
  • 4
    • 3343018873 scopus 로고    scopus 로고
    • Methods to suppress and correct for scatter and emission contamination of post-injection singles transmission in PET
    • May
    • Smith et al., "Methods to suppress and correct for scatter and emission contamination of post-injection singles transmission in PET, " J. Nucl. Med., vol. 39, no. 5 Suppl. S, pp. 139-139, May 1998.
    • (1998) J. Nucl. Med. , vol.39 , Issue.5 SUPPL. S , pp. 139-139
    • Smith1
  • 5
    • 0001472313 scopus 로고    scopus 로고
    • Singles transmission scans performed post-injection for quantitative whole body PET imaging
    • June
    • _, "Singles transmission scans performed post-injection for quantitative whole body PET imaging," IEEE Trans. Nucl. Sci., pt. 2, vol. 44, pp. 1329-1335, June 1997.
    • (1997) IEEE Trans. Nucl. Sci., Pt. 2 , vol.44 , pp. 1329-1335
  • 6
    • 0029513937 scopus 로고
    • An analysis of correction methods for emission contamination in PET postinjection transmission measurement
    • Dec.
    • Luk et al., "An analysis of correction methods for emission contamination in PET postinjection transmission measurement," IEEE Trans. Nucl Sci., pt. 2, vol. 42, pp. 2303-2308, Dec. 1995.
    • (1995) IEEE Trans. Nucl Sci., Pt. 2 , vol.42 , pp. 2303-2308
    • Luk1
  • 7
    • 0042670867 scopus 로고    scopus 로고
    • Strategies for improving the quantitative accuracy of post-injection transmission scans in cardiac PET
    • May
    • Boellaard et al., "Strategies for improving the quantitative accuracy of post-injection transmission scans in cardiac PET," J. Nucl. Med., vol. 42, no. 5 Suppl. S, pp. 842-842, May 2001.
    • (2001) J. Nucl. Med. , vol.42 , Issue.5 SUPPL. S , pp. 842-842
    • Boellaard1
  • 8
    • 0345103297 scopus 로고    scopus 로고
    • Ordered subsets algorithms for transmission tomography
    • Nov.
    • Erdogan and Fessler, "Ordered subsets algorithms for transmission tomography," Phys. Med. Biol., vol. 44, no. 11, pp. 2835-51, Nov. 1999.
    • (1999) Phys. Med. Biol. , vol.44 , Issue.11 , pp. 2835-2851
    • Erdogan1    Fessler2
  • 9
    • 0036816121 scopus 로고    scopus 로고
    • Development of a daily quality check procedure for the high-resolution research tomograph (HRRT) using natural LSO background radioactivity
    • Oct.
    • Knoess et al., "Development of a daily quality check procedure for the high-resolution research tomograph (HRRT) using natural LSO background radioactivity," IEEE Trans. Nucl. Sci., pt. 1, vol. 49, pp. 2074-2078, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci., Pt. 1 , vol.49 , pp. 2074-2078
    • Knoess1
  • 10
    • 3342898063 scopus 로고    scopus 로고
    • Evaluation of the depth of interaction (DOI) for the high resolution research tomograph (HRRT) - A comparison between scanners with and without DOI
    • Norfolk, VA
    • _, "Evaluation of the depth of interaction (DOI) for the high resolution research tomograph (HRRT) - A comparison between scanners with and without DOI," in Proc. Conf. Rec. IEEE Medical Imaging, Norfolk, VA, 2002.
    • (2002) Proc. Conf. Rec. IEEE Medical Imaging


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.