메뉴 건너뛰기




Volumn 37, Issue , 1997, Pages 205-212

Estimation of blood perfusion using a minimally invasive blood perfusion probe

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL EQUIPMENT; COMPUTATIONAL METHODS; FUNCTIONS; HEAT FLUX; HEAT RESISTANCE; MATHEMATICAL MODELS; NONINVASIVE MEDICAL PROCEDURES; PARAMETER ESTIMATION; PROBES; TEMPERATURE MEASUREMENT; TISSUE;

EID: 3342908080     PISSN: 10716947     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Article
Times cited : (22)

References (33)
  • 1
    • 3342929362 scopus 로고    scopus 로고
    • 1986, Laser Doppler Flow Monitor, U.S. Patent 4,596,254. In Laser-Doppler Blood Flowmetry, Ed. A. P. Shepherd, P. Å. Öberg, 1990, Kluwer Academic Publishers
    • Adrian, R. J., and Borgos, J. A., (inventors), 1986, Laser Doppler Flow Monitor, U.S. Patent 4,596,254. In Laser-Doppler Blood Flowmetry, Ed. A. P. Shepherd, P. Å. Öberg, 1990, Kluwer Academic Publishers.
    • Adrian, R.J.1    Borgos, J.A.2
  • 4
    • 0016412705 scopus 로고
    • Theory, Measurement and Application of Thermal Properties of Biomaterials
    • Bowman, H. F., Cravalho, E. G., and Woods, M., 1975, "Theory, Measurement and Application of Thermal Properties of Biomaterials," Ann. Rev. Biophys. Bioeng., Vol. 4, pp. 43-80.
    • (1975) Ann. Rev. Biophys. Bioeng. , vol.4 , pp. 43-80
    • Bowman, H.F.1    Cravalho, E.G.2    Woods, M.3
  • 5
    • 0000008151 scopus 로고
    • Estimation of Tissue Blood Flow
    • Ch. 9 Eds. A. Shitzer and R. C. Eberhart, Plenum Press, N.Y.
    • Bowman, H. F., 1985, "Estimation of Tissue Blood Flow, " Ch. 9 in Heat Transfer in Medicine and Biology, Vol. 1, Eds. A. Shitzer and R. C. Eberhart, Plenum Press, N.Y., pp. 193-230.
    • (1985) Heat Transfer in Medicine and Biology , vol.1 , pp. 193-230
    • Bowman, H.F.1
  • 6
    • 0020613273 scopus 로고
    • Steady-State Analysis and Evaluation of a New Thermal Sensor for Surface Measurements of Tissue Perfusion
    • Ch. 8
    • Castellana, F. S., Skalak, R., Cho, J. M. And Case, R. B., 1983, "Steady-State Analysis and Evaluation of a New Thermal Sensor for Surface Measurements of Tissue Perfusion," Ch. 8 in Annals of Biomedical Engineering, Vol. 11, pp. 101-115.
    • (1983) Annals of Biomedical Engineering , vol.11 , pp. 101-115
    • Castellana, F.S.1    Skalak, R.2    Cho, J.M.3    Case, R.B.4
  • 7
    • 0005644709 scopus 로고
    • Measurements of Thermal Properties of Biological Materials
    • Ch. 8 Eds. A. Shitzer and R. C. Eberhart, Plenum Press, N.Y.
    • Chato, J. C., 1985, "Measurements of Thermal Properties of Biological Materials," Ch. 8 in Heat Transfer in Medicine and Biology, Vol. 1, Eds. A. Shitzer and R. C. Eberhart, Plenum Press, N.Y., pp. 93-122.
    • (1985) Heat Transfer in Medicine and Biology , vol.1 , pp. 93-122
    • Chato, J.C.1
  • 8
    • 0025932804 scopus 로고
    • The Influence of Model Parameter Values on the Prediction of Skin Surface Temperature : II. Contact Problems
    • Cui, Z. F., and Barbenel, J. C., 1991, "The Influence of Model Parameter Values on the Prediction of Skin Surface Temperature : II. Contact Problems," Phys. Med. Biol., Vol. 36, pp. 1607-1620.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1607-1620
    • Cui, Z.F.1    Barbenel, J.C.2
  • 12
    • 0000046778 scopus 로고
    • Estimation of the Nutrient Skin Blood Flow Using a Non-Invasive Segmented Thermal Clearance Probe
    • E. P. Rolfe, Academic Press, London
    • Holti, G., and Mitchell, K. W., 1979, "Estimation of The Nutrient Skin Blood Flow Using a Non-Invasive Segmented Thermal Clearance Probe," in Non-Invasive Physiological Measurements, Vol. 1, E. P. Rolfe, Academic Press, London, pp. 113-123.
    • (1979) Non-Invasive Physiological Measurements , vol.1 , pp. 113-123
    • Holti, G.1    Mitchell, K.W.2
  • 13
    • 0023394036 scopus 로고
    • A Comparative Analysis of Thermal Blood Perfusion Measurement Techniques
    • Kress, R., R. Roemer, 1987, "A Comparative Analysis of Thermal Blood Perfusion Measurement Techniques," Journal of Biomechanical Engineering, Vol. 109, pp. 218-225.
    • (1987) Journal of Biomechanical Engineering , vol.109 , pp. 218-225
    • Kress, R.1    Roemer, R.2
  • 17
    • 0019230971 scopus 로고
    • A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy
    • Nilsson, G. E., Tenland, T., and Öberg, P. Å., 1980, "A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy," IEEE Trans. Biomed. Engr., Vol. 27, pp. 12-19.
    • (1980) IEEE Trans. Biomed. Engr. , vol.27 , pp. 12-19
    • Nilsson, G.E.1    Tenland, T.2    Öberg, P.Å.3
  • 19
    • 84888360034 scopus 로고
    • Analysis of Tissue and Arteriole Blood Temperatures in the Resting Forearm
    • Pennes, H., 1948, "Analysis of Tissue and Arteriole Blood Temperatures in the Resting Forearm," Journal of Applied Physiology, Vol. 1, pp. 93-122.
    • (1948) Journal of Applied Physiology , vol.1 , pp. 93-122
    • Pennes, H.1
  • 20
    • 3342885542 scopus 로고    scopus 로고
    • Development of a Noninvasive Blood Perfusion Probe
    • Hayes, L. J., and Clegg, S., Eds., ASME
    • O'Reilly, T., Gonzales, T., and Diller, T., 1996, "Development of a Noninvasive Blood Perfusion Probe," Advances in Biological Heat and Mass Transfer, HTD-Vol. 337 /BED, Vol. 34, Hayes, L. J., and Clegg, S., Eds., ASME, pp. 67-73.
    • (1996) Advances in Biological Heat and Mass Transfer , vol.34-337 HTD AND BED , pp. 67-73
    • O'Reilly, T.1    Gonzales, T.2    Diller, T.3
  • 21
    • 0015428084 scopus 로고
    • Laser Doppler Measurements of Blood Flow in Capillary Tudes and Retinal Arteries
    • Riva, C. E., Ross, B., and Benedek, G. B., 1972, "Laser Doppler Measurements of Blood Flow in Capillary Tudes and Retinal Arteries," Invest Ophthalmol, Vol. 11, pp. 936-944. In Laser-Doppler Blood Flowmetry, Ed. A. P. Shepherd, P. Å. Öberg, 1990, Kluwer Academic Publishers.
    • (1972) Invest Ophthalmol , vol.11 , pp. 936-944
    • Riva, C.E.1    Ross, B.2    Benedek, G.B.3
  • 22
    • 0015428084 scopus 로고
    • Kluwer Academic Publishers
    • Riva, C. E., Ross, B., and Benedek, G. B., 1972, "Laser Doppler Measurements of Blood Flow in Capillary Tudes and Retinal Arteries," Invest Ophthalmol, Vol. 11, pp. 936-944. In Laser-Doppler Blood Flowmetry, Ed. A. P. Shepherd, P. Å. Öberg, 1990, Kluwer Academic Publishers.
    • (1990) Laser-Doppler Blood Flowmetry
    • Shepherd, A.P.1    Öberg, P.Å.2
  • 23
    • 0002785987 scopus 로고    scopus 로고
    • Estimation of Temperature Dependent Thermal Properties of Basic Food Solutions during Freezing
    • Saad, Z., and Scott, E. P., 1996, "Estimation of Temperature Dependent Thermal Properties of Basic Food Solutions During Freezing," Journal of Food Engineering, Vol. 28, pp. 1-19.
    • (1996) Journal of Food Engineering , vol.28 , pp. 1-19
    • Saad, Z.1    Scott, E.P.2
  • 24
    • 0026711857 scopus 로고
    • Estimation of Thermal Properties in Carbon/Epoxy Composite Materials during Curing
    • Scott, E. P., and Beck, J. V., 1992a, "Estimation of Thermal Properties in Carbon/Epoxy Composite Materials during Curing," Journal of Composite Materials, Vol. 26, No. 1., pp. 20-36.
    • (1992) Journal of Composite Materials , vol.26 , Issue.1 , pp. 20-36
    • Scott, E.P.1    Beck, J.V.2
  • 25
    • 0026714088 scopus 로고
    • Estimation of Thermal Properties in Epoxy Matrix/Carbon Fiber Composite Materials
    • Scott, E. P., and Beck, J. V., 1992b, "Estimation of Thermal Properties in Epoxy Matrix/Carbon Fiber Composite Materials," Journal of Composite Materials, Vol. 26, No. 1., pp. 132-149.
    • (1992) Journal of Composite Materials , vol.26 , Issue.1 , pp. 132-149
    • Scott, E.P.1    Beck, J.V.2
  • 27
    • 0016630468 scopus 로고
    • In Vivo Evaluation of Microcirculation by Coherent Light Scattering
    • Stern, M. D., 1975, "In Vivo Evaluation of Microcirculation by Coherent Light Scattering," Nature, Vol. 254, pp. 56-58.
    • (1975) Nature , vol.254 , pp. 56-58
    • Stern, M.D.1
  • 28
    • 3342981190 scopus 로고    scopus 로고
    • 1978, Method and apparatus for Measurements of Blood Flow Using Coherent Light, U. S. Patent 4,109,647. In Laser-Doppler Blood Flowmetry, Ed. A. P. Shepherd, P. Å. Öberg, 1990, Kluwer Academic Publishers
    • Stern, M. D., and Lappe, D. L., 1978, Method and apparatus for Measurements of Blood Flow Using Coherent Light, U. S. Patent 4,109,647. In Laser-Doppler Blood Flowmetry, Ed. A. P. Shepherd, P. Å. Öberg, 1990, Kluwer Academic Publishers.
    • Stern, M.D.1    Lappe, D.L.2
  • 31
    • 3342922336 scopus 로고
    • Tissue Thermal Diffusivity Measured with Sinusoidally Heated Thermistors
    • Valvano, J. W., Nho, S., 1991, "Tissue Thermal Diffusivity Measured with Sinusoidally Heated Thermistors," Advances in Biological Heat and Mass Transfer, HTD-Vol. 189/BED-Vol. 18, pp. 9-14.
    • (1991) Advances in Biological Heat and Mass Transfer , vol.18-189 HTD AND BED , pp. 9-14
    • Valvano, J.W.1    Nho, S.2
  • 32
    • 0021575750 scopus 로고
    • A Noninvasive Technique for Quantifying Tissue Perfusion
    • Ed. R. L. Spilker, ASME, N. Y.
    • Walsh, J. T., and Bowman, H. F., 1984, "A Noninvasive Technique for Quantifying Tissue Perfusion," in Advances in Bioengineering, Ed. R. L. Spilker, ASME, N. Y., pp. 5-6.
    • (1984) Advances in Bioengineering , pp. 5-6
    • Walsh, J.T.1    Bowman, H.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.