메뉴 건너뛰기




Volumn 13, Issue 6, 2005, Pages 637-642

Mini-fiber-spectrometer adopting micro-silicon-slit

Author keywords

Formula for wavelength calibration; Micro silicon slit; Mini fiber spectrometer; MOEMS; Resolution

Indexed keywords

CALIBRATION; ELECTROMAGNETIC WAVE DIFFRACTION; MICROELECTROMECHANICAL DEVICES; OPTICAL DESIGN;

EID: 33344475779     PISSN: 1004924X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (8)
  • 1
    • 0035264044 scopus 로고    scopus 로고
    • The resolution of optic multichannel analyzer
    • Chinese source
    • YU CH Q, LIU J, LI J Z, et al. The resolution of optic multichannel analyzer[J]. Optical Technique, 2001, 27(2): 97-99. (in Chinese)
    • (2001) Optical Technique , vol.27 , Issue.2 , pp. 97-99
    • Yu, C.Q.1    Liu, J.2    Li, J.Z.3
  • 2
    • 33344462972 scopus 로고    scopus 로고
    • The State of the art of micro spectrometers
    • Chinese source
    • JU H, WU Y H. The State of the art of micro spectrometers[J]. Optics and Precision Engineering, 2001, 9(4): 372-376. (in Chinese)
    • (2001) Optics and Precision Engineering , vol.9 , Issue.4 , pp. 372-376
    • Ju, H.1    Wu, Y.H.2
  • 3
    • 33344455696 scopus 로고    scopus 로고
    • The holographic grating displacement sensors based on linear CCD
    • Chinese source
    • ZHAO Y L, ZHANG Q CH, LI K D. The holographic grating displacement sensors based on linear CCD[J]. Journal of Test and Measurement Technology, 2002, 16(3): 167-170. (in Chinese)
    • (2002) Journal of Test and Measurement Technology , vol.16 , Issue.3 , pp. 167-170
    • Zhao, Y.L.1    Zhang, Q.C.2    Li, K.D.3
  • 4
    • 33344465607 scopus 로고    scopus 로고
    • Study on relationship between the spectrum hand width and the absorbance error
    • Chinese source
    • LI CH H. Study on relationship between the spectrum hand width and the absorbance error[J]. Analysis and Testing Technology and Instruments, 2004, 10(2): 65-67. (in Chinese)
    • (2004) Analysis and Testing Technology and Instruments , vol.10 , Issue.2 , pp. 65-67
    • Li, C.H.1
  • 5
    • 33344455812 scopus 로고    scopus 로고
    • Study on miniaturization of spectrometer for biochemical use
    • Chinese source, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences
    • JU H. Study on miniaturization of spectrometer for biochemical use[D]. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2002. (in Chinese)
    • (2002)
    • Ju, H.1
  • 6
    • 0141561101 scopus 로고    scopus 로고
    • Design of a novel mini-spectrometer
    • Chinese source
    • HU S, WEN ZH Y, et al. Design of a novel mini-spectrometer[J]. Piezoelectrics and Acoustooptics, 2000, 22(6): 363-366. (in Chinese)
    • (2000) Piezoelectrics and Acoustooptics , vol.22 , Issue.6 , pp. 363-366
    • Hu, S.1    Wen, Z.Y.2
  • 7
    • 21844480756 scopus 로고    scopus 로고
    • Wavelength calibration for PC2000-PC/104 spectrometer
    • Chinese source
    • XU ZH M, YU B X. Wavelength calibration for PC2000-PC/104 spectrometer[J]. Optics and Precision Engineering, 2004, 12(1): 11-14. (in Chinese)
    • (2004) Optics and Precision Engineering , vol.12 , Issue.1 , pp. 11-14
    • Xu, Z.M.1    Yu, B.X.2
  • 8
    • 0003712291 scopus 로고    scopus 로고
    • Chinese source, Beijing: Mechanical Industry Press
    • FEI Y T. Error theory and data processing[M]. Beijing: Mechanical Industry Press, 2000. (in Chinese)
    • (2000) Error Theory and Data Processing
    • Fei, Y.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.