Volumn 53, Issue 3, 2006, Pages 478-484

Wavelet-based event detection in implantable cardiac rhythm management devices

Author keywords

Electrogram; Event detection; Implantable cardiac devices; Pacemakers; Wavelets

Indexed keywords

ELECTROGRAM; EVENT DETECTION; IMPLANTABLE CARDIAC DEVICES; WAVELETS;

EID: 33344468504     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2005.869775     Document Type: Article
Times cited : (12)

References (21)
  • 1
    • 0021740872 scopus 로고
    • Interference in pacemakers
    • W. Irnich, "Interference in pacemakers," PACE, vol. 7, pp. 1021-1048, 1984.
    • (1984) PACE , vol.7 , pp. 1021-1048
    • Irnich, W.1
  • 2
    • 0023127808 scopus 로고
    • Muscle noise and interference behavior in pacemakers: A comparative study
    • _, "Muscle noise and interference behavior in pacemakers: a comparative study," PACE, vol. 10, pp. 125-132, 1987.
    • (1987) PACE , vol.10 , pp. 125-132
  • 3
    • 0023138250 scopus 로고
    • Current facts on pacemaker electromagnetic interference and their application to clinical care
    • Mar.
    • D. P. Sager, "Current facts on pacemaker electromagnetic interference and their application to clinical care," Heart Lung, vol. 16, pp. 211-221, Mar. 1987.
    • (1987) Heart Lung , vol.16 , pp. 211-221
    • Sager, D.P.1
  • 5
    • 84888800741 scopus 로고    scopus 로고
    • Oct. HeartWeb. [Online]
    • (1996, Oct.) HeartWeb. [Online]. Available: http://www.heartweb.org/
    • (1996)
  • 6
    • 0027410962 scopus 로고
    • Electronic article surveillance: A possible danger for pacemaker patients
    • Jan.
    • B. Dodinot, J.-P. Godenir, and A. B. Costa, "Electronic article surveillance: a possible danger for pacemaker patients," PACE, vol. 16, pp. 46-53, Jan. 1993.
    • (1993) PACE , vol.16 , pp. 46-53
    • Dodinot, B.1    Godenir, J.-P.2    Costa, A.B.3
  • 7
    • 0031714598 scopus 로고    scopus 로고
    • Study of pacemaker and implantable cardioverter defibrillator triggering by electronic article surveillance devices
    • Oct.
    • M. E. McIvor, J. Reddinger, E. Floden, and R. C. Sheppard, "Study of pacemaker and implantable cardioverter defibrillator triggering by electronic article surveillance devices," PACE, vol. 21, pp. 1847-1861, Oct. 1998.
    • (1998) PACE , vol.21 , pp. 1847-1861
    • McIvor, M.E.1    Reddinger, J.2    Floden, E.3    Sheppard, R.C.4
  • 11
    • 0017626244 scopus 로고
    • Cardiac pacing and pacemakers III. Sensing the cardiac electrogram
    • June
    • S. Furman, P. Hurzeler, and V. D. Caprio, "Cardiac pacing and pacemakers III. Sensing the cardiac electrogram," Am. Heart J., vol. 93, pp. 794-801, June 1977.
    • (1977) Am. Heart J. , vol.93 , pp. 794-801
    • Furman, S.1    Hurzeler, P.2    Caprio, V.D.3
  • 12
    • 0030107497 scopus 로고    scopus 로고
    • Detection algorithms in implantable cardioverter defibrillators
    • Mar.
    • J. Jenkins and S. Caswell, "Detection algorithms in implantable cardioverter defibrillators," Proc. IEEE, vol. 84, pp. 428-145, Mar. 1996.
    • (1996) Proc. IEEE , vol.84 , pp. 428-1145
    • Jenkins, J.1    Caswell, S.2
  • 13
    • 0029304866 scopus 로고
    • A hybrid analog and digital VLSI neural network for intracardiac morphology classification
    • May
    • R. Coggins, M. Jabri, B. Flower, and S. Pickard, "A hybrid analog and digital VLSI neural network for intracardiac morphology classification, " IEEE J. Solid State Circ., vol. 30, pp. 542-550, May 1995.
    • (1995) IEEE J. Solid State Circ. , vol.30 , pp. 542-550
    • Coggins, R.1    Jabri, M.2    Flower, B.3    Pickard, S.4
  • 14
    • 0033282538 scopus 로고    scopus 로고
    • Wavelet based algorithms for EGM morphology discrimination for implantable ICDs
    • L. Koyrakh, J. Oerg, and N. Wood, "Wavelet based algorithms for EGM morphology discrimination for implantable ICDs," Proc. Comput. Cardiol., pp. 343-346, 1999.
    • (1999) Proc. Comput. Cardiol. , pp. 343-346
    • Koyrakh, L.1    Oerg, J.2    Wood, N.3
  • 16
    • 0027938025 scopus 로고
    • The effect of electronic article surveillance systems on permanent cardiac pacemakers
    • Nov.
    • E. H. Lucas, "The effect of electronic article surveillance systems on permanent cardiac pacemakers," PACE, vol. 17, pp. 2021-2026, Nov. 1994.
    • (1994) PACE , vol.17 , pp. 2021-2026
    • Lucas, E.H.1
  • 17
    • 0034018374 scopus 로고    scopus 로고
    • Study of interactions between permanent pacemakers and electronic antitheft surveillance systems
    • Mar.
    • J. Mugica, L. Henry, and H. Podeur, "Study of interactions between permanent pacemakers and electronic antitheft surveillance systems," PACE, vol. 23, pp. 333-337, Mar. 2000.
    • (2000) PACE , vol.23 , pp. 333-337
    • Mugica, J.1    Henry, L.2    Podeur, H.3
  • 19
    • 0022216083 scopus 로고
    • Intracardiac electrograms and sensing test signals: Electrophysiological, physical and technical considerations
    • W. Irnich, "Intracardiac electrograms and sensing test signals: electrophysiological, physical and technical considerations," PACE, vol. 8, pp. 870-888, 1985.
    • (1985) PACE , vol.8 , pp. 870-888
    • Irnich, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.