메뉴 건너뛰기




Volumn 67, Issue 2, 2006, Pages 288-295

Evaluation of acoustic wave propagation velocities in the ocular lens and vitreous tissues of pigs, dogs, and rabbits

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ACOUSTICS; AGE; ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; AUDITORY STIMULATION; CORRELATION ANALYSIS; DIFFRACTION; DOG DISEASE; ECHOGRAPHY; ENUCLEATION; LENS DISEASE; LENS POWER; LENSECTOMY; MATHEMATICAL COMPUTING; METHODOLOGY; NONHUMAN; RABBIT; REACTION TIME; SENSORY NERVE CONDUCTION; SOUND TRANSMISSION; SWINE DISEASE; TEMPERATURE SENSITIVITY; TISSUE SECTION; VETERINARY MEDICINE; VITREOUS BODY; WAVEFORM;

EID: 33344467529     PISSN: 00029645     EISSN: None     Source Type: Journal    
DOI: 10.2460/ajvr.67.2.288     Document Type: Article
Times cited : (24)

References (35)
  • 1
    • 0000297590 scopus 로고
    • Ultrasonics in ocular diagnosis
    • Mundt GH, Hughes WF. Ultrasonics in ocular diagnosis. Am J Ophthalmol 1956;41:488-498.
    • (1956) Am J Ophthalmol , vol.41 , pp. 488-498
    • Mundt, G.H.1    Hughes, W.F.2
  • 2
    • 0008616293 scopus 로고
    • A study on the measurement of ocular axial length by ultrasonic echography
    • Yamamoto Y, Namiki R, Baba M, et al. A study on the measurement of ocular axial length by ultrasonic echography. Jpn J Ophthalmol 1961;5:58-63.
    • (1961) Jpn J Ophthalmol , vol.5 , pp. 58-63
    • Yamamoto, Y.1    Namiki, R.2    Baba, M.3
  • 3
    • 11744343027 scopus 로고
    • Measuring the length of the eye with the help of ultrasonic echo
    • Franken S. Measuring the length of the eye with the help of ultrasonic echo. Ophthalmologica 1962;143:82-85.
    • (1962) Ophthalmologica , vol.143 , pp. 82-85
    • Franken, S.1
  • 4
    • 0002815521 scopus 로고    scopus 로고
    • Physics of diagnostic ultrasound
    • Zagzebski JA, ed. St Louis: Mosby Year Book Inc
    • Zagzebski JA. Physics of diagnostic ultrasound. In: Zagzebski JA, ed. Essentials of ultrasound physics. St Louis: Mosby Year Book Inc, 1996;1-19.
    • (1996) Essentials of Ultrasound Physics , pp. 1-19
    • Zagzebski, J.A.1
  • 5
    • 0021285405 scopus 로고
    • Biometrische Untersuchungen des Kaninchenauges
    • Uthoff D. Biometrische Untersuchungen des Kaninchenauges. Klin Mbl Augenheilk 1984;185:189-192.
    • (1984) Klin Mbl Augenheilk , vol.185 , pp. 189-192
    • Uthoff, D.1
  • 6
    • 0345731598 scopus 로고
    • Measurement of the velocity of sound in some part of the eye
    • Oksala A, Lehtinen A. Measurement of the velocity of sound in some part of the eye. Acta Ophthalmol 1958;36:633-639.
    • (1958) Acta Ophthalmol , vol.36 , pp. 633-639
    • Oksala, A.1    Lehtinen, A.2
  • 10
    • 0033022297 scopus 로고    scopus 로고
    • Naturally occurring vitreous chamber-based myopia in the Labrador Retriever
    • Mutti DO, Zadnik K, Murphy CJ. Naturally occurring vitreous chamber-based myopia in the Labrador Retriever. Invest Ophthalmol Vis Sci 1999;40:1577-1584.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , pp. 1577-1584
    • Mutti, D.O.1    Zadnik, K.2    Murphy, C.J.3
  • 11
    • 0020133061 scopus 로고
    • Biometric study of the canine eye using A-mode ultrasonography
    • Schiffer SP, Rantanen NW, Leary GA, et al. Biometric study of the canine eye using A-mode ultrasonography. Am J Vet Res 1980;43:826-830.
    • (1980) Am J Vet Res , vol.43 , pp. 826-830
    • Schiffer, S.P.1    Rantanen, N.W.2    Leary, G.A.3
  • 12
    • 0000948603 scopus 로고
    • Determination of the velocity of ultrasound in the human lens and vitreous
    • Jansson F, Kock E. Determination of the velocity of ultrasound in the human lens and vitreous. Acta Ophthalmol 1962;40:420-433.
    • (1962) Acta Ophthalmol , vol.40 , pp. 420-433
    • Jansson, F.1    Kock, E.2
  • 13
    • 0015536173 scopus 로고
    • Ocular-dioptric-component changes in the growing rabbit
    • Ludlam WM, Twarowski CJ. Ocular-dioptric-component changes in the growing rabbit. J Opt Soc Am 1973;63:95-98.
    • (1973) J Opt Soc Am , vol.63 , pp. 95-98
    • Ludlam, W.M.1    Twarowski, C.J.2
  • 14
    • 0012416206 scopus 로고
    • Determination of the velocity of ultrasound in ocular tissues at different temperatures
    • Jansson F, Sundmark E. Determination of the velocity of ultrasound in ocular tissues at different temperatures. Acta Ophthalmol 1961;39:899-910.
    • (1961) Acta Ophthalmol , vol.39 , pp. 899-910
    • Jansson, F.1    Sundmark, E.2
  • 15
    • 33344468808 scopus 로고
    • Determination of the speed of ultrasound in the ocular tissues of humans and swine
    • Rivara A, Sanna G. Determination of the speed of ultrasound in the ocular tissues of humans and swine. Ann Ottalmol Clin Ocul 1962;88:672-682.
    • (1962) Ann Ottalmol Clin Ocul , vol.88 , pp. 672-682
    • Rivara, A.1    Sanna, G.2
  • 16
    • 0002872434 scopus 로고    scopus 로고
    • Physiology of the eye
    • Gelatt KN, ed. 3rd ed. Philadelphia: Lippincott Williams & Wilkins
    • Gum GG, Gelatt KN, Ofri R. Physiology of the eye. In: Gelatt KN, ed. Veterinary ophthalmology. 3rd ed. Philadelphia: Lippincott Williams & Wilkins, 1999;151-181.
    • (1999) Veterinary Ophthalmology , pp. 151-181
    • Gum, G.G.1    Gelatt, K.N.2    Ofri, R.3
  • 17
    • 0025940296 scopus 로고
    • Apparatus for ultrasound tissue characterization of excised specimens
    • Arditi M, Edmonds PD, Jensen JF, et al. Apparatus for ultrasound tissue characterization of excised specimens. Ultrason Imaging 1991;13:280-297.
    • (1991) Ultrason Imaging , vol.13 , pp. 280-297
    • Arditi, M.1    Edmonds, P.D.2    Jensen, J.F.3
  • 18
    • 0036821003 scopus 로고    scopus 로고
    • Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue
    • Techavipoo U, Varghese T, Zagzebski JA,et al. Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue. Ultrason Imaging 2002;24:246-260.
    • (2002) Ultrason Imaging , vol.24 , pp. 246-260
    • Techavipoo, U.1    Varghese, T.2    Zagzebski, J.A.3
  • 19
    • 0023019512 scopus 로고
    • Interlaboratory comparison of ultrasonic attenuation and speed measurements
    • Madsen EL, Frank GR, Carson PL, et al. Interlaboratory comparison of ultrasonic attenuation and speed measurements. J Ultrasound Med 1986;5:569-576.
    • (1986) J Ultrasound Med , vol.5 , pp. 569-576
    • Madsen, E.L.1    Frank, G.R.2    Carson, P.L.3
  • 20
    • 0004294033 scopus 로고
    • Ultrasonic biometry
    • Coleman DJ, Lizzi FL, Jack RL, eds. Philadelphia: Lea & Febiger
    • Coleman DJ, Lizzi FL, Jack RL. Ultrasonic biometry. In: Coleman DJ, Lizzi FL, Jack RL, eds. Ultrasonography of the eye and orbit. Philadelphia: Lea & Febiger, 1977;91-141.
    • (1977) Ultrasonography of the Eye and Orbit , pp. 91-141
    • Coleman, D.J.1    Lizzi, F.L.2    Jack, R.L.3
  • 21
    • 0023181168 scopus 로고
    • Developmental aspects of experimental myopia in chicks: Susceptibility, recovery and relation to emmetropization
    • Wallman J, Adams JI. Developmental aspects of experimental myopia in chicks: susceptibility, recovery and relation to emmetropization. Vision Res 1987;27:1139-1163.
    • (1987) Vision Res , vol.27 , pp. 1139-1163
    • Wallman, J.1    Adams, J.I.2
  • 22
    • 0023849624 scopus 로고
    • A finite element model of heat transport in the human eye
    • Scott JA. A finite element model of heat transport in the human eye. Phys Med Biol 1988;33:227-241.
    • (1988) Phys Med Biol , vol.33 , pp. 227-241
    • Scott, J.A.1
  • 23
    • 0017724521 scopus 로고
    • Temperature measurements in the eye
    • Rosenbluth RF, Fatt I. Temperature measurements in the eye. Exp Eye Res 1977;25:325-341.
    • (1977) Exp Eye Res , vol.25 , pp. 325-341
    • Rosenbluth, R.F.1    Fatt, I.2
  • 24
    • 0014976536 scopus 로고
    • The elastic constants of the human lens
    • Fisher RF. The elastic constants of the human lens. J Physiol 1971;212:147-180.
    • (1971) J Physiol , vol.212 , pp. 147-180
    • Fisher, R.F.1
  • 25
    • 0024599510 scopus 로고
    • Local variation in absolute water content of human and rabbit eye lenses measured by Raman microspectroscopy
    • Huizinga A, Bot AC, de Mul FF, et al. Local variation in absolute water content of human and rabbit eye lenses measured by Raman microspectroscopy. Exp Eye Res 1989;48:487-496.
    • (1989) Exp Eye Res , vol.48 , pp. 487-496
    • Huizinga, A.1    Bot, A.C.2    de Mul, F.F.3
  • 26
    • 0028033110 scopus 로고
    • Relation between local acoustic parameters and protein distribution in human and porcine eye lenses
    • De Korte CL, Van Der Steen AF, Thijssen JM, et al. Relation between local acoustic parameters and protein distribution in human and porcine eye lenses. Exp Eye Res 1994;59:617-627.
    • (1994) Exp Eye Res , vol.59 , pp. 617-627
    • De Korte, C.L.1    Van Der Steen, A.F.2    Thijssen, J.M.3
  • 27
    • 0034003134 scopus 로고    scopus 로고
    • Structural macromolecules and supramolecular organisation of the vitreous gel
    • Bishop PN. Structural macromolecules and supramolecular organisation of the vitreous gel. Prog Retin Eye Res 2000; 19:323-344.
    • (2000) Prog Retin Eye Res , vol.19 , pp. 323-344
    • Bishop, P.N.1
  • 28
    • 0025882397 scopus 로고
    • Elasticity of tissues involved in accommodation
    • van Alphen GW, Graebel WP. Elasticity of tissues involved in accommodation. Vision Res 1991;31:1417-1438.
    • (1991) Vision Res , vol.31 , pp. 1417-1438
    • van Alphen, G.W.1    Graebel, W.P.2
  • 29
    • 0028346141 scopus 로고
    • Presbyopia and velocity of sound in the lens
    • Beers AP, van der Heijde GL. Presbyopia and velocity of sound in the lens. Opt Vision Sci 1993;74:250-253.
    • (1993) Opt Vision Sci , vol.74 , pp. 250-253
    • Beers, A.P.1    van der Heijde, G.L.2
  • 30
    • 84975565838 scopus 로고
    • Accommodation and presbyopia in the human eye I: Evaluation of in vivo measurement techniques
    • Koretz JF, Kaufman PL, Neider MW, et al. Accommodation and presbyopia in the human eye I: evaluation of in vivo measurement techniques. Appl Opt 1989;28:1097-1102.
    • (1989) Appl Opt , vol.28 , pp. 1097-1102
    • Koretz, J.F.1    Kaufman, P.L.2    Neider, M.W.3
  • 31
    • 0016612218 scopus 로고
    • A determination of the velocity of ultrasound in cataractous lenses
    • Coleman DJ, Lizzi FL, Franzen LA, et al. A determination of the velocity of ultrasound in cataractous lenses. Bibl Ophthalmol 1975;83:246-251.
    • (1975) Bibl Ophthalmol , vol.83 , pp. 246-251
    • Coleman, D.J.1    Lizzi, F.L.2    Franzen, L.A.3
  • 33
    • 0026348239 scopus 로고
    • Variability of quantitative echographic parameters of the liver: Intra- and interindividual spread, temporal- and age-related effects
    • Hartman PJ, Oosterveld BJ, Thijssen JM, et al. Variability of quantitative echographic parameters of the liver: intra- and interindividual spread, temporal- and age-related effects. Ultrasound Med Biol 1991;13:857-867.
    • (1991) Ultrasound Med Biol , vol.13 , pp. 857-867
    • Hartman, P.J.1    Oosterveld, B.J.2    Thijssen, J.M.3
  • 34
    • 2942648071 scopus 로고    scopus 로고
    • Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses
    • Techavipoo U, Varghese T, Chen Q, et al. Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses. J Acoust Soc Am 2004;115:2859-2865.
    • (2004) J Acoust Soc Am , vol.115 , pp. 2859-2865
    • Techavipoo, U.1    Varghese, T.2    Chen, Q.3
  • 35
    • 0031113219 scopus 로고    scopus 로고
    • Effect of optical defocus on visual acuity in the dog
    • Murphy CJ, Mutti DO, Zadnik K, et al. Effect of optical defocus on visual acuity in the dog. Am J Vet Res 1997;58:414-418.
    • (1997) Am J Vet Res , vol.58 , pp. 414-418
    • Murphy, C.J.1    Mutti, D.O.2    Zadnik, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.