메뉴 건너뛰기




Volumn 32, Issue 3, 2006, Pages 460-463

Influence of infusion flow rates on central venous pressure measurements through multi-lumen central venous catheters in intensive care

Author keywords

Acute circulatory failure; Central venous pressure; Vascular capacitance

Indexed keywords

NORADRENALIN; SODIUM CHLORIDE;

EID: 33344462547     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-005-0049-6     Document Type: Article
Times cited : (6)

References (14)
  • 1
    • 0034533742 scopus 로고    scopus 로고
    • Accuracy of totally implanted ports, tunnelled, single- And multiple-lumen central venous catheters for measurement of central venous pressure
    • Blot F, Laplanche A (2000) Accuracy of totally implanted ports, tunnelled, single- and multiple-lumen central venous catheters for measurement of central venous pressure. Intensive Care Med 26:1837-1842
    • (2000) Intensive Care Med , vol.26 , pp. 1837-1842
    • Blot, F.1    Laplanche, A.2
  • 2
    • 0031873704 scopus 로고    scopus 로고
    • More respect for the CVP
    • Magder S (1998) More respect for the CVP. Intensive Care Med 24:651-653
    • (1998) Intensive Care Med , vol.24 , pp. 651-653
    • Magder, S.1
  • 3
    • 0031892916 scopus 로고    scopus 로고
    • Volume replacement strategies on intensive care units: Results from a postal survey
    • Boldt J, Lenz M, Kumle B, Papsdorf M (1998) Volume replacement strategies on intensive care units: results from a postal survey. Intensive Care Med 24:147-151
    • (1998) Intensive Care Med , vol.24 , pp. 147-151
    • Boldt, J.1    Lenz, M.2    Kumle, B.3    Papsdorf, M.4
  • 6
    • 0031602175 scopus 로고    scopus 로고
    • Influence of port site on central venous pressure measurements from triple-lumen catheters in critically ill adults
    • Scott SS, Giuliano KK, Pysznik E, Elliott S, Welsh K, Delbuono N (1998) Influence of port site on central venous pressure measurements from triple-lumen catheters in critically ill adults. Am J Crit Care 7:60-63
    • (1998) Am J Crit Care , vol.7 , pp. 60-63
    • Scott, S.S.1    Giuliano, K.K.2    Pysznik, E.3    Elliott, S.4    Welsh, K.5    Delbuono, N.6
  • 7
    • 20644440408 scopus 로고    scopus 로고
    • How to use central venous pressure measurements
    • Magder S (2005) How to use central venous pressure measurements. Curr Opin Crit Care 11:264-270
    • (2005) Curr Opin Crit Care , vol.11 , pp. 264-270
    • Magder, S.1
  • 8
    • 0030603624 scopus 로고    scopus 로고
    • Comparison of intrathoracic and intra-abdominal measurements of central venous pressure
    • Joynt GM, Gomersall CD, Buckley TA, Oh TE, Young RJ, Freebairn RC (1996) Comparison of intrathoracic and intra-abdominal measurements of central venous pressure. Lancet 347:1155-1157
    • (1996) Lancet , vol.347 , pp. 1155-1157
    • Joynt, G.M.1    Gomersall, C.D.2    Buckley, T.A.3    Oh, T.E.4    Young, R.J.5    Freebairn, R.C.6
  • 9
    • 0022416363 scopus 로고
    • Maximum infusion rates and CVP accuracy during high-flow delivery through multilumen catheters
    • Ikeda S, Schweiss J (1985) Maximum infusion rates and CVP accuracy during high-flow delivery through multilumen catheters. Crit Care Med 13:586-588
    • (1985) Crit Care Med , vol.13 , pp. 586-588
    • Ikeda, S.1    Schweiss, J.2
  • 10
    • 0011224357 scopus 로고
    • Pressure-volume curves of the arterial and venous systems in live dogs
    • Guyton AC, Armstrong GG, Chipley PL (1956) Pressure-volume curves of the arterial and venous systems in live dogs. Am J Physiol 184:253-258
    • (1956) Am J Physiol , vol.184 , pp. 253-258
    • Guyton, A.C.1    Armstrong, G.G.2    Chipley, P.L.3
  • 13
    • 0017064870 scopus 로고
    • Effective vascular compliance and venous diameter in dogs
    • Larochelle P, Ogilvie RI (1976) Effective vascular compliance and venous diameter in dogs. Can J Physiol Pharmacol 54:154-159
    • (1976) Can J Physiol Pharmacol , vol.54 , pp. 154-159
    • Larochelle, P.1    Ogilvie, R.I.2
  • 14
    • 0015966092 scopus 로고
    • Effective compliance of the total vascular bed and the intrathoracic compartment derived from changes in central venous pressure induced by volume changes in man
    • Echt M, Duweling J, Gauer OH, Lange L (1974) Effective compliance of the total vascular bed and the intrathoracic compartment derived from changes in central venous pressure induced by volume changes in man. Circ Res 40:61-68
    • (1974) Circ Res , vol.40 , pp. 61-68
    • Echt, M.1    Duweling, J.2    Gauer, O.H.3    Lange, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.