메뉴 건너뛰기




Volumn 21, Issue 1, 2006, Pages 85-94

Experimental study of inter-laminar core fault detection techniques based on low flux core excitation

Author keywords

AC machines; Inter laminar insulation failure; Regular maintenance; Stator core fault; Stator core inspection

Indexed keywords

ALGORITHMS; ELECTRIC EXCITATION; INSULATION; SIGNAL TO NOISE RATIO; STATORS;

EID: 33244460550     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2005.853759     Document Type: Article
Times cited : (24)

References (19)
  • 1
    • 33244455745 scopus 로고    scopus 로고
    • Pacificorp Hunter I Outage Filing [Online]. Available:
    • Pacificorp Hunter I Outage Filing [Online]. Available: http:// www.commerce.state.ut.us/ccs/HunterIFiling.htm
  • 6
    • 0022206607 scopus 로고
    • "Report of large motor reliability survey of industrial and commercial installations: Part I and II"
    • P. O'Donnell, "Report of large motor reliability survey of industrial and commercial installations: Part I and II," IEEE Trans. Ind. Appl., vol. 21, no. 4, pp. 853-872, 1985.
    • (1985) IEEE Trans. Ind. Appl. , vol.21 , Issue.4 , pp. 853-872
    • O'Donnell, P.1
  • 12
    • 0005166901 scopus 로고
    • "El-CID - An easier way to test stator cores"
    • Jul
    • J. Sutton, "El-CID - An easier way to test stator cores," Elect. Rev., vol. 207, no. 1, pp. 33-37, Jul. 1980.
    • (1980) Elect. Rev. , vol.207 , Issue.1 , pp. 33-37
    • Sutton, J.1
  • 14
    • 84968754166 scopus 로고
    • "Electrical machine core imperfection detection"
    • May
    • C. Rickson, "Electrical machine core imperfection detection," Proc. Inst. Elect. Eng., pt. B, vol. 133, no. 3, pp. 190-195, May 1986.
    • (1986) Proc. Inst. Elect. Eng. , vol.133 , Issue.3 PART B , pp. 190-195
    • Rickson, C.1
  • 16
    • 0035274547 scopus 로고    scopus 로고
    • "Inspection of stator cores in large machines with a low yoke induction method-measurement and analysis of interlamination short-circuits"
    • Mar
    • Z. Posedel, "Inspection of stator cores in large machines with a low yoke induction method-measurement and analysis of interlamination short-circuits," IEEE Trans. Energy Conversion, vol. 16, no. 1, pp. 81-86, Mar. 2001.
    • (2001) IEEE Trans. Energy Conversion , vol.16 , Issue.1 , pp. 81-86
    • Posedel, Z.1
  • 18
    • 20544448489 scopus 로고    scopus 로고
    • "An iron core probe based inter-laminar core fault detection technique for generator stator cores"
    • Jun
    • S. B. Lee, G. B. Kliman, M. R. Shah, N. K. Nair, and R. M. Lusted, "An iron core probe based inter-laminar core fault detection technique for generator stator cores," IEEE Trans. Energy Convers., vol. 20, no. 2, pp. 344-351, Jun. 2005.
    • (2005) IEEE Trans. Energy Convers. , vol.20 , Issue.2 , pp. 344-351
    • Lee, S.B.1    Kliman, G.B.2    Shah, M.R.3    Nair, N.K.4    Lusted, R.M.5
  • 19
    • 0242676336 scopus 로고    scopus 로고
    • "An advanced technique for detecting inter-laminar stator core faults in large electric machines"
    • S. B. Lee, G. B. Kliman, M. R. Shah, W. T. Mall, N. K. Nair, and R. M. Lusted, "An advanced technique for detecting inter-laminar stator core faults in large electric machines," in Proc. IEEE IAS Annu. Meeting, vol. 2, 2003, pp. 1374-1381.
    • (2003) Proc. IEEE IAS Annu. Meeting , vol.2 , pp. 1374-1381
    • Lee, S.B.1    Kliman, G.B.2    Shah, M.R.3    Mall, W.T.4    Nair, N.K.5    Lusted, R.M.6