메뉴 건너뛰기




Volumn , Issue , 2004, Pages 109-114

Transcranial ultrasonography system aided by fuzzy model

Author keywords

Cattle Head; Fuzzy logic; Human Head; Transcranial sonography; Ultrasonic device

Indexed keywords

BONE; BRAIN; FUZZY CONTROL; TISSUE; ULTRASONIC DEVICES;

EID: 32844454376     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (13)
  • 1
    • 0035658252 scopus 로고    scopus 로고
    • Transcranial ultrasound clinical applications in cerebral ischaemia
    • C. R. Levi, C. Seimes, and B. R. Chambers, "Transcranial Ultrasound Clinical Applications in Cerebral Ischaemia," Australian Prescriber, vol. 24, no. 6, pp. 137-140, 2001.
    • (2001) Australian Prescriber , vol.24 , Issue.6 , pp. 137-140
    • Levi, C.R.1    Seimes, C.2    Chambers, B.R.3
  • 2
    • 32844459472 scopus 로고    scopus 로고
    • Perspectives of cerebral sonography in neurology
    • G. Becker, "Perspectives of Cerebral Sonography in Neurology," Electromedica vol. 68: Neuro, pp. 21-26, 2000.
    • (2000) Electromedica Vol. 68: Neuro , vol.68 , pp. 21-26
    • Becker, G.1
  • 3
    • 0036592972 scopus 로고    scopus 로고
    • Transcranial Doppler sonography in children: Review of a seven-year experience
    • June
    • W. Hirsch, W. Hiebsch, H. Teichler, and A. Schluter, "Transcranial Doppler Sonography in Children: Review of a Seven-year Experience", Clinical Radiology, vol. 57, no. 6, pp. 492-497, June. 2002.
    • (2002) Clinical Radiology , vol.57 , Issue.6 , pp. 492-497
    • Hirsch, W.1    Hiebsch, W.2    Teichler, H.3    Schluter, A.4
  • 5
    • 0024872588 scopus 로고
    • Ultrasonic echo tomography trough skullbone
    • J. Ylitalo, and J. Koivukangas, "Ultrasonic Echo Tomography Trough Skullbone," Ultrasonics Symposium, pp. 1019-1022, 1989.
    • (1989) Ultrasonics Symposium , pp. 1019-1022
    • Ylitalo, J.1    Koivukangas, J.2
  • 7
    • 0027985396 scopus 로고
    • Reliability of transcranial colourcoded real-time sonography in the assessment of brain tumors: Correlation between ultrasound, computerized tomography and biopsy findings
    • G. Becker, A. Krone, D. Koulis, A. Lindner, E. Hofmann, W. Roggendorf, and U. Bogdahn, "Reliability of Transcranial Colourcoded Real-time Sonography in the Assessment of Brain Tumors: Correlation between Ultrasound, Computerized Tomography and Biopsy Findings," Neuroradiology vol. 36, pp. 585-590, 1994.
    • (1994) Neuroradiology , vol.36 , pp. 585-590
    • Becker, G.1    Krone, A.2    Koulis, D.3    Lindner, A.4    Hofmann, E.5    Roggendorf, W.6    Bogdahn, U.7
  • 8
    • 0036334723 scopus 로고    scopus 로고
    • Perspectives of B-mode transcranial ultrasound
    • D. Berg, and G. Becker, "Perspectives of B-Mode Transcranial Ultrasound," Neurolmage 15, 463-473, 2002.
    • (2002) Neurolmage , vol.15 , pp. 463-473
    • Berg, D.1    Becker, G.2