메뉴 건너뛰기




Volumn 27, Issue 2, 2006, Pages 155-164

Continuous indirect calorimetry - A laboratory simulation of a new method for non-invasive metabolic monitoring of patients under anaesthesia or in critical care

Author keywords

Anaesthesia; Gas flow; Haldane transformation; Oxygen consumption

Indexed keywords

ANESTHESIOLOGY; CALORIMETERS; CALORIMETRY; GASES; OXYGEN;

EID: 32544453696     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/2/006     Document Type: Article
Times cited : (6)

References (14)
  • 1
  • 2
    • 0016639110 scopus 로고
    • Totally closed circuit nitrous oxide/oxygen anaesthesia
    • Barton F and Nunn J F 1975 Totally closed circuit nitrous oxide/oxygen anaesthesia Br. J. Anaesth. 47 350-7
    • (1975) Br. J. Anaesth. , vol.47 , pp. 350-357
    • Barton, F.1    Nunn, J.F.2
  • 3
    • 0023156833 scopus 로고
    • Continuous measurement of oxygen uptake. Evaluation of the Engstrom metabolic computer and clinical experiences
    • Behrendt W, Weiland C, Kalff J and Giani G 1987 Continuous measurement of oxygen uptake. Evaluation of the Engstrom metabolic computer and clinical experiences Acta Anaesthesiol. Scand. 31 10-4
    • (1987) Acta Anaesthesiol. Scand. , vol.31 , pp. 10-14
    • Behrendt, W.1    Weiland, C.2    Kalff, J.3    Giani, G.4
  • 4
    • 0032007225 scopus 로고    scopus 로고
    • 2 measurement
    • 2 measurement J. Clin. Monit. 14 141-4
    • (1998) J. Clin. Monit. , vol.14 , Issue.2 , pp. 141-144
    • Biro, P.1
  • 5
    • 0005534353 scopus 로고
    • The administration of nitrous oxide-oxygen anesthesia in closed systems
    • Foldes F F, Ceravolo A J and Carpenter S L 1952 The administration of nitrous oxide-oxygen anesthesia in closed systems Ann. Surg. 136 978-81
    • (1952) Ann. Surg. , vol.136 , pp. 978-981
    • Foldes, F.F.1    Ceravolo, A.J.2    Carpenter, S.L.3
  • 6
    • 0036308817 scopus 로고    scopus 로고
    • Measurement of systemic oxygen uptake during low-flow anaesthesia with a standard technique versus a novel method
    • Leonard I E, Weitkamp B, Jones K, Aittomaki J and Myles P S 2002 Measurement of systemic oxygen uptake during low-flow anaesthesia with a standard technique versus a novel method Anaesthesia 57 654-8
    • (2002) Anaesthesia , vol.57 , Issue.7 , pp. 654-658
    • Leonard, I.E.1    Weitkamp, B.2    Jones, K.3    Aittomaki, J.4    Myles, P.S.5
  • 8
    • 0025193542 scopus 로고
    • Evaluation of metabolic measuring instruments for use in critically ill patients
    • Makita K, Nunn J F and Royston B 1990 Evaluation of metabolic measuring instruments for use in critically ill patients Crit. Care Med. 18 638-44
    • (1990) Crit. Care Med. , vol.18 , pp. 638-644
    • Makita, K.1    Nunn, J.F.2    Royston, B.3
  • 9
    • 1342268938 scopus 로고    scopus 로고
    • A new method for measurement of gas exchange during anaesthesia using an extractable marker gas
    • Peyton P J, Robinson G J B, Terry D and Junor P A 2004 A new method for measurement of gas exchange during anaesthesia using an extractable marker gas Physiol. Meas. 25 1-14
    • (2004) Physiol. Meas. , vol.25 , Issue.1 , pp. 1-14
    • Peyton, P.J.1    Robinson, G.J.B.2    Terry, D.3    Junor, P.A.4
  • 10
    • 4344677815 scopus 로고    scopus 로고
    • Continuous measurement of gas uptake and elimination in anesthetized patients using an extractable marker gas
    • Robinson G, Peyton P, Terry D, Malekzadeh S and Thompson B 2004 Continuous measurement of gas uptake and elimination in anesthetized patients using an extractable marker gas J. Appl. Physiol. 97 960-6
    • (2004) J. Appl. Physiol. , vol.97 , Issue.3 , pp. 960-966
    • Robinson, G.1    Peyton, P.2    Terry, D.3    Malekzadeh, S.4    Thompson, B.5
  • 11
    • 2942611292 scopus 로고    scopus 로고
    • Accuracy of the Foldes-Biro equation for measurement of oxygen uptake during anaesthesia: A laboratory simulation
    • Stuart-Andrews C, Peyton P, Robinson G J B and Lithgow B 2004 Accuracy of the Foldes-Biro equation for measurement of oxygen uptake during anaesthesia: a laboratory simulation Anaesthesia 59 541-4
    • (2004) Anaesthesia , vol.59 , Issue.6 , pp. 541-544
    • Stuart-Andrews, C.1    Peyton, P.2    Robinson, G.J.B.3    Lithgow, B.4
  • 12
    • 0024423390 scopus 로고    scopus 로고
    • Measurement of gas exchange in intensive care: Laboratory and clinical validation of a new device
    • Takala J, Keinanen O, Vaisanen P and Kari A 1998 Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device Crit. Care Med. 17 1041-7
    • (1998) Crit. Care Med. , vol.17 , pp. 1041-1047
    • Takala, J.1    Keinanen, O.2    Vaisanen, P.3    Kari, A.4
  • 14
    • 0036652512 scopus 로고    scopus 로고
    • Development and in vitro validation of a device for measuring non-shunt cardiac output by nitrous oxide throughflow
    • Vartuli G M, Burfoot R B, Robinson G J B, Peyton P J and Junor P A 2002 Development and in vitro validation of a device for measuring non-shunt cardiac output by nitrous oxide throughflow Med. Biol. Eng. Comput. 40 415-22
    • (2002) Med. Biol. Eng. Comput. , vol.40 , Issue.4 , pp. 415-422
    • Vartuli, G.M.1    Burfoot, R.B.2    Robinson, G.J.B.3    Peyton, P.J.4    Junor, P.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.