메뉴 건너뛰기




Volumn 24, Issue 2, 2004, Pages 155-164

Performance characteristics of LiF thermoluminescent dosemeters employed in the national personnel radiation dose services in Tanzania

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETERS; LITHIUM COMPOUNDS; LUMINESCENCE; MEASUREMENT THEORY; RADIATION EFFECTS; RADIATION PROTECTION;

EID: 3242785765     PISSN: 09524746     EISSN: None     Source Type: Journal    
DOI: 10.1088/0952-4746/24/2/005     Document Type: Article
Times cited : (3)

References (19)
  • 4
    • 3242762328 scopus 로고
    • Basic principles for occupational radiation monitoring
    • IAEA (International Atomic Energy Agency) (Vienna: IAEA)
    • IAEA (International Atomic Energy Agency) 1987 Basic principles for occupational radiation monitoring Safety Series No 84 (Vienna: IAEA)
    • (1987) Safety Series No 84
  • 5
    • 3242747602 scopus 로고    scopus 로고
    • UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) (Report to General Assembly with Scientific Annexes) (New York: United Nations) (United Nations Sales Publication E.00.1x.3)
    • UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) 2000 Sources and Effects of Ionizing Radiation (Report to General Assembly with Scientific Annexes) (New York: United Nations) pp 21, 500-5 (United Nations Sales Publication E.00.1x.3)
    • (2000) Sources and Effects of Ionizing Radiation , vol.21 , pp. 500-505
  • 6
    • 3242791025 scopus 로고    scopus 로고
    • Occupational dose trends in Tanzania IAEATECDOC-1031
    • (Vienna: IAEA)
    • Muhogora W E, Nyanda A M, Ngaile J E and Lema U S 1998 Occupational dose trends in Tanzania IAEATECDOC-1031 (Vienna: IAEA) pp 105-11
    • (1998) , pp. 105-111
    • Muhogora, W.E.1    Nyanda, A.M.2    Ngaile, J.E.3    Lema, U.S.4
  • 7
    • 3242806114 scopus 로고    scopus 로고
    • Regulatory control of low-level radiation exposure IAEA-TECDOC-976
    • (Vienna: IAEA)
    • Nyanda AM and Muhogora WE 1997 Regulatory control of low-level radiation exposure IAEA-TECDOC-976 (Vienna: IAEA) pp 308-11
    • (1997) , pp. 308-311
    • Nyanda, A.M.1    Muhogora, W.E.2
  • 8
    • 0036019168 scopus 로고    scopus 로고
    • Energy response of LiF:Mg, Ti dosemeters to ISO 4037 and typical diagnostic x-ray beams in Tanzania
    • Muhogora W E, Ngoye W N, Lema U S and Mwalongo D 2002 Energy response of LiF:Mg, Ti dosemeters to ISO 4037 and typical diagnostic x-ray beams in Tanzania J. Radiol. Prot. 22 175-84
    • (2002) J. Radiol. Prot. , vol.22 , pp. 175-184
    • Muhogora, W.E.1    Ngoye, W.N.2    Lema, U.S.3    Mwalongo, D.4
  • 9
    • 0024916261 scopus 로고
    • Conversion factors for the IAEA cube phantom for external photon irradiation
    • Grosswendt B 1989 Conversion factors for the IAEA cube phantom for external photon irradiation Radiat. Prot. Dosim. 29 177-82
    • (1989) Radiat. Prot. Dosim. , vol.29 , pp. 177-182
    • Grosswendt, B.1
  • 10
    • 0003884120 scopus 로고
    • Measurements of dose equivalents from external photon and electron radiation ICRU Report 47
    • ICRU (International Commission on Radiation Units and Measurements) (Bethesda, MD: ICRU)
    • ICRU (International Commission on Radiation Units and Measurements) 1992 Measurements of dose equivalents from external photon and electron radiation ICRU Report 47 (Bethesda, MD: ICRU)
    • (1992)
  • 11
    • 0026601877 scopus 로고
    • Detection and determination limits for thermoluminescence dosimetry
    • Hirning C R 1992 Detection and determination limits for thermoluminescence dosimetry Health Phys. 62 (3) 223-7
    • (1992) Health Phys. , vol.62 , Issue.3 , pp. 223-227
    • Hirning, C.R.1
  • 12
    • 0026595588 scopus 로고
    • Determining the lower limit of detection for personnel dosimetry systems
    • Roberson P L and Carlson R D 1992 Determining the lower limit of detection for personnel dosimetry systems Health Phys. 62 (1) 2-9
    • (1992) Health Phys. , vol.62 , Issue.1 , pp. 2-9
    • Roberson, P.L.1    Carlson, R.D.2
  • 13
    • 0003487059 scopus 로고
    • Quantities and units in radiation protection dosimetry ICRU Report 51
    • ICRU (International Commission on Radiation Units and Measurements) (Bethesda, MD: ICRU)
    • ICRU (International Commission on Radiation Units and Measurements) 1993 Quantities and units in radiation protection dosimetry ICRU Report 51 (Bethesda, MD: ICRU) pp 7-8
    • (1993) , pp. 7-8
  • 14
    • 0003588624 scopus 로고    scopus 로고
    • IAEA (International Atomic Energy Agency) (IAEA International Safety Series Safety Guide No. RS-G-1.3) (Vienna: IAEA) (STIPUB1076)
    • IAEA (International Atomic Energy Agency) 1999 Assessment of Occupational Exposure Due to External Sources of Radiation (IAEA International Safety Series Safety Guide No. RS-G-1.3) (Vienna: IAEA) (STIPUB1076)
    • (1999) Assessment of Occupational Exposure Due to External Sources of Radiation
  • 15
    • 3242743808 scopus 로고
    • IAEA (International Atomic Energy Agency) (Vienna: IAEA)
    • IAEA (International Atomic Energy Agency) 1993 Proc. Symp. on Measurement Assurance in Dosimetry (Vienna: IAEA) pp 541-6
    • (1993) Proc. Symp. on Measurement Assurance in Dosimetry , pp. 541-546
  • 16
    • 0342463796 scopus 로고
    • Radiation doses in diagnostic radiology and methods of dose reduction IAEA-TECDOC-796
    • IAEA (International Atomic Energy Agency) (Vienna: IAEA)
    • IAEA (International Atomic Energy Agency) 1995 Radiation doses in diagnostic radiology and methods of dose reduction IAEA-TECDOC-796 (Vienna: IAEA)
    • (1995)
  • 19
    • 3242752828 scopus 로고    scopus 로고
    • Harshaw/Fitrol TLD system 4000 Reader Users Manual (HarshawlFitrol Partner Crystal and Electronic Products, 68001 Cochran Road, Solon, OH 44139)
    • Harshaw/Fitrol TLD system 4000 Reader Users Manual (HarshawlFitrol Partner Crystal and Electronic Products, 68001 Cochran Road, Solon, OH 44139)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.