메뉴 건너뛰기




Volumn 78, Issue 2, 2004, Pages 722-724

Interrupted distal anastomosis: The interrupted "porcupine" technique

Author keywords

23

Indexed keywords

ANASTOMOSIS; ARTERY ANASTOMOSIS; ARTICLE; CORONARY ARTERY; END TO SIDE ANASTOMOSIS; LEFT ANTERIOR DESCENDING CORONARY ARTERY; MEDICAL PRACTICE; PRACTICE GUIDELINE; PRIORITY JOURNAL; PROCESS DEVELOPMENT; SURGICAL APPROACH; SURGICAL EQUIPMENT; SURGICAL TECHNIQUE; VEIN ANASTOMOSIS;

EID: 3242757665     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2003.11.006     Document Type: Article
Times cited : (9)

References (6)
  • 1
    • 0041842601 scopus 로고    scopus 로고
    • Clinical and six month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device: A multicenter prospective clinical trial
    • Wold R.K., Alderman E.L., Caskey M.P., et al. Clinical and six month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device a multicenter prospective clinical trial. J Thorac Cardiovasc Surg. 126:2003;168-178
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 168-178
    • Wold, R.K.1    Alderman, E.L.2    Caskey, M.P.3
  • 2
    • 0018564965 scopus 로고
    • Technique for performance of internal mammary artery-coronary artery anastomosis
    • Loop F.D. Technique for performance of internal mammary artery-coronary artery anastomosis. J Thorac Cardiovasc Surg. 79:1979;460-463
    • (1979) J Thorac Cardiovasc Surg , vol.79 , pp. 460-463
    • Loop, F.D.1
  • 3
    • 0033534083 scopus 로고    scopus 로고
    • Frequency of early occlusion and stenosis in a left internal mammary artery after surgery through a median sternotomy on conventional bypass
    • Berger P.B., Alderman E.L., Nadel N., Schaff H.V. Frequency of early occlusion and stenosis in a left internal mammary artery after surgery through a median sternotomy on conventional bypass. Circulation. 100:1999;2353-2358
    • (1999) Circulation , vol.100 , pp. 2353-2358
    • Berger, P.B.1    Alderman, E.L.2    Nadel, N.3    Schaff, H.V.4
  • 4
    • 0042200767 scopus 로고    scopus 로고
    • Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses
    • Ballyk P.D., Walsh C., Butany J., Ojha M. Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses. J Biomech. 31:1998;229-237
    • (1998) J Biomech , vol.31 , pp. 229-237
    • Ballyk, P.D.1    Walsh, C.2    Butany, J.3    Ojha, M.4
  • 5
    • 0022629896 scopus 로고
    • Influence on the internal mammary artery graft on 10-year survival and other cardiac events
    • Loop F.D., Lytle B.W., Cosgrove D.M., et al. Influence on the internal mammary artery graft on 10-year survival and other cardiac events. N Engl J Med. 314:1986;1-6
    • (1986) N Engl J Med , vol.314 , pp. 1-6
    • Loop, F.D.1    Lytle, B.W.2    Cosgrove, D.M.3
  • 6
    • 0035353694 scopus 로고    scopus 로고
    • Facilitated coronary anastomosis using a nitinol U-Clip device: Bovine model
    • Hill A.C., Maroney Y.P., Virmani R. Facilitated coronary anastomosis using a nitinol U-Clip device bovine model. J Cardiovasc Surg. 121:2001;859-869
    • (2001) J Cardiovasc Surg , vol.121 , pp. 859-869
    • Hill, A.C.1    Maroney, Y.P.2    Virmani, R.3