-
2
-
-
0037114398
-
A new vascular prosthesis coated with polyamino-acid urethane copolymer (PAU) to enhance endothelialization
-
Wang, C., Zhang, Q., Uchida, S. and Kodama, M. A new vascular prosthesis coated with polyamino-acid urethane copolymer (PAU) to enhance endothelialization. J. Biomed. Mater. Res. 62 (2002), 315-322.
-
(2002)
J. Biomed. Mater. Res.
, vol.62
, pp. 315-322
-
-
Wang, C.1
Zhang, Q.2
Uchida, S.3
Kodama, M.4
-
3
-
-
0036240422
-
Poly2-methoxyethylacrylate (PMEA) coated oxygenator: An ex vivo study
-
Mueller, X.M., Jegger, D., Augstburger, M., Horisberger, J. and von Segesser, L.K. Poly2-methoxyethylacrylate (PMEA) coated oxygenator: an ex vivo study. Int. J. Artif. Organs 25 (2002), 223-229.
-
(2002)
Int. J. Artif. Organs
, vol.25
, pp. 223-229
-
-
Mueller, X.M.1
Jegger, D.2
Augstburger, M.3
Horisberger, J.4
Von Segesser, L.K.5
-
4
-
-
0036164232
-
MMA/MPEOMA/VSA copolymer as a novel blood-compatible material: Effect of PEO and negatively charged side chains on protein adsorption and platelet adhesion
-
Lee, J.H. and Oh, S.H. MMA/MPEOMA/VSA copolymer as a novel blood-compatible material: effect of PEO and negatively charged side chains on protein adsorption and platelet adhesion. J. Biomed. Mater. Res. 60 (2002), 44-52.
-
(2002)
J. Biomed. Mater. Res.
, vol.60
, pp. 44-52
-
-
Lee, J.H.1
Oh, S.H.2
-
5
-
-
0035892448
-
A novel phosphorylcholine-coated contact lens for extended wear use
-
Court, J.L., Redman, R.P., Wang, J.H., Leppard, S.W., Obyrne, V.J., Small, S.A., Lewis, A.L., Jones, S.A. and Stratford, P.W. A novel phosphorylcholine-coated contact lens for extended wear use. Biomaterials 22 (2001), 3261-3272.
-
(2001)
Biomaterials
, vol.22
, pp. 3261-3272
-
-
Court, J.L.1
Redman, R.P.2
Wang, J.H.3
Leppard, S.W.4
Obyrne, V.J.5
Small, S.A.6
Lewis, A.L.7
Jones, S.A.8
Stratford, P.W.9
-
6
-
-
0034028072
-
Surfactant polymers designed to suppress bacterial (Staphylococcus epidermidis) adhesion on biomaterials
-
Vacheethasanee, K. and Marchant, R.E. Surfactant polymers designed to suppress bacterial (Staphylococcus epidermidis) adhesion on biomaterials. J. Biomed. Mater. Res. 50 (2000), 302-312.
-
(2000)
J. Biomed. Mater. Res.
, vol.50
, pp. 302-312
-
-
Vacheethasanee, K.1
Marchant, R.E.2
-
7
-
-
0032706817
-
Photochemically immobilized polymer coatings: Effects on protein adsorption, cell adhesion, and leukocyte activation
-
Defife, K.M., Hagen, K.M., Clapper, D.L. and Anderson, J.M. Photochemically immobilized polymer coatings: effects on protein adsorption, cell adhesion, and leukocyte activation. J. Biomater. Sci. Polym. Ed. 10 (1999), 1063-1074.
-
(1999)
J. Biomater. Sci. Polym. Ed.
, vol.10
, pp. 1063-1074
-
-
Defife, K.M.1
Hagen, K.M.2
Clapper, D.L.3
Anderson, J.M.4
-
8
-
-
0036720192
-
Heparin-releasing intravascular guide wires
-
Hanssen, J.H.L. and Koole, L.H. Heparin-releasing intravascular guide wires. Med. Device Technol. 13 (2002), 20-22.
-
(2002)
Med. Device Technol.
, vol.13
, pp. 20-22
-
-
Hanssen, J.H.L.1
Koole, L.H.2
-
9
-
-
0034947271
-
Towards retrievable vascularized bioartificial pancreas: Induction and long-lasting stability of polymeric mesh implant vascularized with the help of acidic and basic fibroblast growth factors and hydrogel coating
-
Prokop, A., Kozlov, E., Nun Non, S., Dikov, M.M., Sephel, G.C., Whitsitt, J.S. and Davidson, J.M. Towards retrievable vascularized bioartificial pancreas: induction and long-lasting stability of polymeric mesh implant vascularized with the help of acidic and basic fibroblast growth factors and hydrogel coating. Diabetes Technol. Ther. 3 (2001), 245-261.
-
(2001)
Diabetes Technol. Ther.
, vol.3
, pp. 245-261
-
-
Prokop, A.1
Kozlov, E.2
Nun Non, S.3
Dikov, M.M.4
Sephel, G.C.5
Whitsitt, J.S.6
Davidson, J.M.7
-
10
-
-
0033808892
-
Surface modification of poly(ethylene terephthalate) angioplasty balloons with a hydrophilic poly(acrylamide-co-ethylene glycol) interpenetrating polymer network coating
-
Park, S., Bearinger, J.P., Lautenschlager, E.P., Castner, D.G. and Healy, K.E. Surface modification of poly(ethylene terephthalate) angioplasty balloons with a hydrophilic poly(acrylamide-co-ethylene glycol) interpenetrating polymer network coating. J. Biomed. Mater. Res. 53 (2000), 568-576.
-
(2000)
J. Biomed. Mater. Res.
, vol.53
, pp. 568-576
-
-
Park, S.1
Bearinger, J.P.2
Lautenschlager, E.P.3
Castner, D.G.4
Healy, K.E.5
-
11
-
-
0034255811
-
Modulating the biocompatibility of polymer surfaces with poly(ethylene glycol): Effect of fibronectin
-
Altankov, G., Thom, V., Groth, T., Jankova, K., Jonsson, G. and Ulbricht, M. Modulating the biocompatibility of polymer surfaces with poly(ethylene glycol): effect of fibronectin. J. Biomed. Mater. Res. 52 (2000), 219-230.
-
(2000)
J. Biomed. Mater. Res.
, vol.52
, pp. 219-230
-
-
Altankov, G.1
Thom, V.2
Groth, T.3
Jankova, K.4
Jonsson, G.5
Ulbricht, M.6
-
12
-
-
0036745028
-
Stent coating: A new approach in interventional cardiology
-
Review
-
Wieneke, H., Sawitowski, T., Wnendt, S., Fischer, A., Dirsch, O., Karoussos, I.A. and Erbel, R. Stent coating: a new approach in interventional cardiology. Herz 27 (2002), 518-526 (Review).
-
(2002)
Herz
, vol.27
, pp. 518-526
-
-
Wieneke, H.1
Sawitowski, T.2
Wnendt, S.3
Fischer, A.4
Dirsch, O.5
Karoussos, I.A.6
Erbel, R.7
-
13
-
-
0037137286
-
Coated stents for the prevention of restenosis. Part I
-
Babapulle, M.N. and Eisenberg, M.J. Coated stents for the prevention of restenosis. Part I. Circulation 106 (2002), 2734-2740. Part II. Circulation 106 (2002), 2859-2866.
-
(2002)
Circulation
, vol.106
, pp. 2734-2740
-
-
Babapulle, M.N.1
Eisenberg, M.J.2
-
14
-
-
0037180418
-
Coated stents for the prevention of restenosis. Part II
-
Babapulle, M.N. and Eisenberg, M.J. Coated stents for the prevention of restenosis. Part I. Circulation 106 (2002), 2734-2740. Part II. Circulation 106 (2002), 2859-2866.
-
(2002)
Circulation
, vol.106
, pp. 2859-2866
-
-
-
15
-
-
0033667551
-
Neointimal thickening after stent delivery of paclitaxel: Change in composition and arrest of growth over six months
-
Drachman, D.E., Edelman, E.R., Seifert, P., Groothuis, A.R., Bornstein, D.A., Kamath, K.R., Palasis, M., Yang, D., Nott, S.H. and Rogers, C. Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months. J. Am. Coll. Cardiol. 36 (2000), 2325-2332.
-
(2000)
J. Am. Coll. Cardiol.
, vol.36
, pp. 2325-2332
-
-
Drachman, D.E.1
Edelman, E.R.2
Seifert, P.3
Groothuis, A.R.4
Bornstein, D.A.5
Kamath, K.R.6
Palasis, M.7
Yang, D.8
Nott, S.H.9
Rogers, C.10
-
16
-
-
0037469230
-
Two-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries
-
Sousa, J.E., Costa, M.A., Sousa, A.G., Abizaid, A.C., Seixas, A.C., Abizaid, A.S., Feres, F., Mattos, L.A., Falotico, R., Jaeger, J., Popma J.J. and Serruys, P.W. Two-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries. Circulation 107 (2003), 381-383.
-
(2003)
Circulation
, vol.107
, pp. 381-383
-
-
Sousa, J.E.1
Costa, M.A.2
Sousa, A.G.3
Abizaid, A.C.4
Seixas, A.C.5
Abizaid, A.S.6
Feres, F.7
Mattos, L.A.8
Falotico, R.9
Jaeger, J.10
Popma, J.J.11
Serruys, P.W.12
-
17
-
-
0036901913
-
Clinical experience with drug-eluting stents
-
Review
-
Drachman, D.E. Clinical experience with drug-eluting stents. Rev. Cardiovasc. Med. 3 (2002), S31-37 (Review).
-
(2002)
Rev. Cardiovasc. Med.
, vol.3
-
-
Drachman, D.E.1
-
18
-
-
0037323224
-
A new era in the treatment of coronary disease?
-
Morice, M.C. A new era in the treatment of coronary disease? Eur. Heart J. 24 (2003), 209-211.
-
(2003)
Eur. Heart J.
, vol.24
, pp. 209-211
-
-
Morice, M.C.1
-
19
-
-
0032746855
-
Metallic wires with an adherent lubricious and blood-compatible polymeric coating and their use in the manufacture of novel slippery-when-wet guide wires: Possible applications related to controlled local drug delivery
-
Hanssen, J.H.L., Wetzels, G.M., Benzina, A., van der Veen, F.H., Lindhout, T. and Koole, L.H. Metallic wires with an adherent lubricious and blood-compatible polymeric coating and their use in the manufacture of novel slippery-when-wet guide wires: possible applications related to controlled local drug delivery. J. Biomed. Mater. Res. 48 (1999), 820-828.
-
(1999)
J. Biomed. Mater. Res.
, vol.48
, pp. 820-828
-
-
Hanssen, J.H.L.1
Wetzels, G.M.2
Benzina, A.3
Van Der Veen, F.H.4
Lindhout, T.5
Koole, L.H.6
-
20
-
-
1842858290
-
Heparin release from slippery-when-wet guide wires for intravascular use
-
Peerlings, C.C., Hanssen, J.H.L., Bevers, R.T., Boelen, E.J., Stelt, B.J., Korthagen, E.J. and Koole, L.H. Heparin release from slippery-when-wet guide wires for intravascular use. J. Biomed. Mater. Res. 63 (2002), 692-698.
-
(2002)
J. Biomed. Mater. Res.
, vol.63
, pp. 692-698
-
-
Peerlings, C.C.1
Hanssen, J.H.L.2
Bevers, R.T.3
Boelen, E.J.4
Stelt, B.J.5
Korthagen, E.J.6
Koole, L.H.7
-
21
-
-
1242272827
-
Coils and tubes releasing heparin. Studies on a new vascular graft prototype
-
Aldenhoff, Y.B.J., Knetsch, M.L.W., Hanssen, J.H., Lindhout, T., Wielders, S.J. and Koole, L.H. Coils and tubes releasing heparin. Studies on a new vascular graft prototype. Biomaterials 25 (2004), 3125-3133.
-
(2004)
Biomaterials
, vol.25
, pp. 3125-3133
-
-
Aldenhoff, Y.B.J.1
Knetsch, M.L.W.2
Hanssen, J.H.3
Lindhout, T.4
Wielders, S.J.5
Koole, L.H.6
-
22
-
-
85119764783
-
-
Merck Index, Merck & Co., Inc. (Rahway, NJ, USA), 11th edn., 1989, entry # 891, p. 138
-
Merck Index, Merck & Co., Inc. (Rahway, NJ, USA), 11th edn., 1989, entry # 891, p. 138. See also: A.A. al-Badr and F.J. Muhtadi. In: Analytical Profiles of Drug Substances, Vol. 14, K. Flory, Ed., Academic Press (New York, NY, USA), pp. 325-389 (1985).
-
-
-
-
23
-
-
77956932238
-
-
K. Flory, Ed., Academic Press (New York, NY, USA)
-
Merck Index, Merck & Co., Inc. (Rahway, NJ, USA), 11th edn., 1989, entry # 891, p. 138. See also: A.A. al-Badr and F.J. Muhtadi. In: Analytical Profiles of Drug Substances, Vol. 14, K. Flory, Ed., Academic Press (New York, NY, USA), pp. 325-389 (1985).
-
(1985)
Analytical Profiles of Drug Substances
, vol.14
, pp. 325-389
-
-
Al-Badr, A.A.1
Muhtadi, F.J.2
-
24
-
-
0021228217
-
-
Merck Index, Merck & Co., Inc. (Rahway, NJ, USA), 11th Edn, 1989, entry # 2068, p. 318
-
Merck Index, Merck & Co., Inc. (Rahway, NJ, USA), 11th Edn, 1989, entry # 2068, p. 318. See also: Shalit, I. and Marks, M.I. Drugs 28 (1984), 281-291.
-
-
-
-
25
-
-
0021228217
-
-
Merck Index, Merck & Co., Inc. (Rahway, NJ, USA), 11th Edn, 1989, entry # 2068, p. 318. See also: Shalit, I. and Marks, M.I. Drugs 28 (1984), 281-291.
-
(1984)
Drugs
, vol.28
, pp. 281-291
-
-
Shalit, I.1
Marks, M.I.2
-
26
-
-
0002048272
-
-
Marcel Dekker Inc. (New York, NY, USA), A.K. Mitra, Ed.
-
Bawa, R. In: Ophthalmic Drug Delivery Systems, Marcel Dekker Inc. (New York, NY, USA), A.K. Mitra, Ed., pp. 223-259 (1993).
-
(1993)
Ophthalmic Drug Delivery Systems
, pp. 223-259
-
-
Bawa, R.1
-
27
-
-
0345065548
-
-
Marcel Dekker Inc. (New York, NY, USA), A.K. Mitra, Ed.
-
Richardson, M.C. and Bentley, P.H. In: Ophthalmic Drug Delivery Systems, Marcel Dekker Inc. (New York, NY, USA), A.K. Mitra, Ed., pp. 355-367 (1993).
-
(1993)
Ophthalmic Drug Delivery Systems
, pp. 355-367
-
-
Richardson, M.C.1
Bentley, P.H.2
-
28
-
-
0004189601
-
-
Marcel Dekker Inc. (New York, NY, USA)
-
Chien, Y.W. In: Novel Drug Delivery Systems, Marcel Dekker Inc. (New York, NY, USA), pp. 13-50 (1982).
-
(1982)
Novel Drug Delivery Systems
, pp. 13-50
-
-
Chien, Y.W.1
-
29
-
-
0016242615
-
Diffusional systems for controlled release of drugs to the eye
-
Shell, J.W. and Baker, R.W. Diffusional systems for controlled release of drugs to the eye. Ann. Ophthalmol. 6 (1974), 1037-1045.
-
(1974)
Ann. Ophthalmol.
, vol.6
, pp. 1037-1045
-
-
Shell, J.W.1
Baker, R.W.2
-
30
-
-
0016675338
-
Ocusert, summary of a round-table discussion
-
Leydhecker, W. Ocusert, summary of a round-table discussion. Klin. Monatsbl. Augenheilk. 6 (1975), 917-8.
-
(1975)
Klin. Monatsbl. Augenheilk.
, vol.6
, pp. 917-918
-
-
Leydhecker, W.1
-
31
-
-
0017890140
-
Soluble gentamicin ophthalmic inserts as a drug delivery system
-
Bloomfield, S.E., Miyata, T., Dunn, M.W., Bueser, N., Stenzel, K.H. and Rubin, A.L. Soluble gentamicin ophthalmic inserts as a drug delivery system. Arch. Ophthalm. 96 (1978), 885-887.
-
(1978)
Arch. Ophthalm.
, vol.96
, pp. 885-887
-
-
Bloomfield, S.E.1
Miyata, T.2
Dunn, M.W.3
Bueser, N.4
Stenzel, K.H.5
Rubin, A.L.6
-
32
-
-
0017387960
-
A soluble sustained release ophthalmic delivery unit
-
Katz, I.M. and Blackmann, W.M. A soluble sustained release ophthalmic delivery unit. Am. J. Ophthalm. 83 (1977), 728-734.
-
(1977)
Am. J. Ophthalm.
, vol.83
, pp. 728-734
-
-
Katz, I.M.1
Blackmann, W.M.2
-
34
-
-
11144320261
-
Local tolerance and in vivo release study of a new ocular drug delivery system
-
Aiache, J.-M., el Meski, S., Serpin, G., Beyssac, E. and Conti, R. Local tolerance and in vivo release study of a new ocular drug delivery system. Drug Deliv. Systems & Sciences 2 (2002), 85-88.
-
(2002)
Drug Deliv. Systems & Sciences
, vol.2
, pp. 85-88
-
-
Aiache, J.-M.1
El Meski, S.2
Serpin, G.3
Beyssac, E.4
Conti, R.5
-
35
-
-
0032945790
-
Formulation and in vivo evaluation of an ocular insert containing phenylephrine and tropicamine
-
Lee, Y.-C., Millard, J.W., Negvesky, G.J., Butrus, S.I. and Yalkowski, S.H. Formulation and in vivo evaluation of an ocular insert containing phenylephrine and tropicamine. Int. J. Pharm. 182 (1999), 121-126.
-
(1999)
Int. J. Pharm.
, vol.182
, pp. 121-126
-
-
Lee, Y.-C.1
Millard, J.W.2
Negvesky, G.J.3
Butrus, S.I.4
Yalkowski, S.H.5
-
36
-
-
12144289295
-
One-sided insert as a unique ophthalmic drug delivery system
-
Sasaki, H., Nagano, T., Sakanaka, K., Kawakami, S., Nishida, K., Nakamura, J., Ichikawa, N., Nakamura, T. and Nashima, M. One-sided insert as a unique ophthalmic drug delivery system. J. Contr. Release 92 (2003), 241-247.
-
(2003)
J. Contr. Release
, vol.92
, pp. 241-247
-
-
Sasaki, H.1
Nagano, T.2
Sakanaka, K.3
Kawakami, S.4
Nishida, K.5
Nakamura, J.6
Ichikawa, N.7
Nakamura, T.8
Nashima, M.9
-
37
-
-
0038402606
-
Mucoadhesive ocular insert based on thiolated poly(acrylic acid): Development and in vivo evaluation in humans
-
Hornof, M., Weyenberg, W., Ludwig, A. and Bernkop-Schnurch, A. Mucoadhesive ocular insert based on thiolated poly(acrylic acid): development and in vivo evaluation in humans. J. Contr. Release 89 (2003), 419-428.
-
(2003)
J. Contr. Release
, vol.89
, pp. 419-428
-
-
Hornof, M.1
Weyenberg, W.2
Ludwig, A.3
Bernkop-Schnurch, A.4
-
38
-
-
0035856772
-
Evaluation of a mucoadhesive tablet for ocular use
-
Ceulemans, J., Vermaire, A., Adriaens, E., Remon, J.P. and Ludwig, A. Evaluation of a mucoadhesive tablet for ocular use. J. Contr. Release 77 (2001), 333-344.
-
(2001)
J. Contr. Release
, vol.77
, pp. 333-344
-
-
Ceulemans, J.1
Vermaire, A.2
Adriaens, E.3
Remon, J.P.4
Ludwig, A.5
-
39
-
-
0043025346
-
Ion-activated in situ gelling systems for sustained ophthalmic delivery of cyprofloxacin hydrochloride
-
Balasubramaniam, J. and Pandit, J.K. Ion-activated in situ gelling systems for sustained ophthalmic delivery of cyprofloxacin hydrochloride. Drug Deliv. 10 (2003), 185-191.
-
(2003)
Drug Deliv.
, vol.10
, pp. 185-191
-
-
Balasubramaniam, J.1
Pandit, J.K.2
|