메뉴 건너뛰기




Volumn 31, Issue 1, 2004, Pages 55-58

Biomechanical properties of PVA hydrogel prosthetic nucleus

Author keywords

Artificial organ; Biomechanics; Intervertebral disc; Prosthetic nucleus

Indexed keywords

BIOMECHANICS; CADAVERIC EXPERIMENTS; IMPLANTS (SURGICAL); MEDICAL PROBLEMS; STIFFNESS;

EID: 3242685332     PISSN: 16728467     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (8)
  • 1
    • 3242671379 scopus 로고    scopus 로고
    • Chinese source
  • 2
    • 0036605819 scopus 로고    scopus 로고
    • New technologies in spine: Nucleus replacement
    • Bao QB, Yuan HA. New technologies in spine: nucleus replacement. Spine, 2002, 27(11):1245
    • (2002) Spine , vol.27 , Issue.11 , pp. 1245
    • Bao, Q.B.1    Yuan, H.A.2
  • 3
    • 0025825634 scopus 로고
    • Change of disc height, radial disc bulge, and intradiscal pressure from discectomy. An in vitro investigation on human lumbar discs
    • Brinckmann P, Grootenboer H. Change of disc height, radial disc bulge, and intradiscal pressure from discectomy. An in vitro investigation on human lumbar discs. Spine, 1991, 16(6):641
    • (1991) Spine , vol.16 , Issue.6 , pp. 641
    • Brinckmann, P.1    Grootenboer, H.2
  • 4
    • 0034001311 scopus 로고    scopus 로고
    • Effect of removing the nucleus pulposus on the deformation of the annulus fibrosus during compression of the intervertebral disc
    • Meakin JR, Hukins DW. Effect of removing the nucleus pulposus on the deformation of the annulus fibrosus during compression of the intervertebral disc. J Biomech, 2000, 33(5):575
    • (2000) J Biomech , vol.33 , Issue.5 , pp. 575
    • Meakin, J.R.1    Hukins, D.W.2
  • 5
    • 0035134562 scopus 로고    scopus 로고
    • The effect of partial removal of the nucleus pulposus from the intervertebral disc on the response of the human annulus fibrosus to compression
    • Meakin JR, Redpath TW, Hukins DW. The effect of partial removal of the nucleus pulposus from the intervertebral disc on the response of the human annulus fibrosus to compression. Clin Biomech (Bristol, Avon), 2001, 16(2):121
    • (2001) Clin Biomech (Bristol, Avon) , vol.16 , Issue.2 , pp. 121
    • Meakin, J.R.1    Redpath, T.W.2    Hukins, D.W.3
  • 6
    • 0036035626 scopus 로고    scopus 로고
    • Spine arthroplasty: A historical review
    • Szpalski M, Gunzburg R, Mayer M. Spine arthroplasty: a historical review. Eur Spine J, 2002, 11(Suppl 2):S65
    • (2002) Eur Spine J , vol.11 , Issue.SUPPL. 2
    • Szpalski, M.1    Gunzburg, R.2    Mayer, M.3
  • 7
    • 0026166086 scopus 로고
    • Lumbar intervertebral disc prosthesis. An experimental study
    • Hou TS, Tu KY, Xu YK, et al. Lumbar intervertebral disc prosthesis. An experimental study. Chin Med J (Engl), 1991, 104(5):381
    • (1991) Chin Med J (Engl) , vol.104 , Issue.5 , pp. 381
    • Hou, T.S.1    Tu, K.Y.2    Xu, Y.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.