메뉴 건너뛰기




Volumn 280, Issue 1-2, 2004, Pages 173-183

Antimicrobial activity of polyurethanes coated with antibiotics: A new approach to the realization of medical devices exempt from microbial colonization

Author keywords

Amoxicillin; Antibiotic coating; Central venous catheters; Device related infections; Polyurethanes; Rifampin

Indexed keywords

AMOXICILLIN; ANTIBIOTIC AGENT; POLYMER; POLYURETHAN; RIFAMPICIN;

EID: 3242684169     PISSN: 03785173     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijpharm.2004.05.017     Document Type: Article
Times cited : (57)

References (17)
  • 1
    • 0029835494 scopus 로고    scopus 로고
    • Retention of the antibiotic teicoplanin on a hydromer-coated central venous catheter to prevent bacterial colonization in postoperative surgical patients
    • Bach A., Darby D., Bottiger B., Bohrer H., Motsch J., Martin E. Retention of the antibiotic teicoplanin on a hydromer-coated central venous catheter to prevent bacterial colonization in postoperative surgical patients. Int. Care Med. 22:1996;1066-1069
    • (1996) Int. Care Med. , vol.22 , pp. 1066-1069
    • Bach, A.1    Darby, D.2    Bottiger, B.3    Bohrer, H.4    Motsch, J.5    Martin, E.6
  • 2
    • 0036669206 scopus 로고    scopus 로고
    • Antibiofilm approaches: Prevention of catheter colonization
    • Danese P.N. Antibiofilm approaches: prevention of catheter colonization. Chem. Biol. 9:2002;873-880
    • (2002) Chem. Biol. , vol.9 , pp. 873-880
    • Danese, P.N.1
  • 4
    • 0035696412 scopus 로고    scopus 로고
    • Efficacy of antiadhesive, antibiotic and antiseptic coating in preventing catherter-related infections
    • Donelli G., Francolini I. Efficacy of antiadhesive, antibiotic and antiseptic coating in preventing catherter-related infections. J. Chemother. 13:2001;56-67
    • (2001) J. Chemother. , vol.13 , pp. 56-67
    • Donelli, G.1    Francolini, I.2
  • 5
    • 0036228505 scopus 로고    scopus 로고
    • Biofilms: Survival mechanisms of clinically relevant microrganisms
    • Donlan R.M., Costerton J.W. Biofilms: survival mechanisms of clinically relevant microrganisms. Clin. Microbiol. Rev. 15:2002;167-193
    • (2002) Clin. Microbiol. Rev. , vol.15 , pp. 167-193
    • Donlan, R.M.1    Costerton, J.W.2
  • 6
    • 0034026081 scopus 로고    scopus 로고
    • Intravascular catheter-related sepsis - Novel methods of prevention
    • Elliott T. Intravascular catheter-related sepsis - novel methods of prevention. Int. Care Med. 26:2000;S45-S50
    • (2000) Int. Care Med. , vol.26 , pp. 45-S50
    • Elliott, T.1
  • 8
    • 0032030942 scopus 로고    scopus 로고
    • Reduced intravascular catheter-related infection by routine use of antibiotic-bonded catheters in a surgical intensive care unit
    • Kamal G.D., Divishek D., Kumar G.C., Porter B.R., Tatman D.J., Adams J.R. Reduced intravascular catheter-related infection by routine use of antibiotic-bonded catheters in a surgical intensive care unit. Diagn. Microbiol. Infect. Dis. 30:1998;145-152
    • (1998) Diagn. Microbiol. Infect. Dis. , vol.30 , pp. 145-152
    • Kamal, G.D.1    Divishek, D.2    Kumar, G.C.3    Porter, B.R.4    Tatman, D.J.5    Adams, J.R.6
  • 9
    • 0035014383 scopus 로고    scopus 로고
    • Mechanisms of biofilm resistance to antimicrobial agents
    • Mah T.F., O'Toole G.A. Mechanisms of biofilm resistance to antimicrobial agents. Trends Microbiol. 9:2001;34-39
    • (2001) Trends Microbiol. , vol.9 , pp. 34-39
    • Mah, T.F.1    O'Toole, G.A.2
  • 10
    • 0037322324 scopus 로고    scopus 로고
    • Which antimicrobial impregnated central venous catheter should we use? Modeling the costs and outcomes of antimicrobial catheter use
    • Marciante K.D., Veenstra D.L., Lipsky B.A., Saint S. Which antimicrobial impregnated central venous catheter should we use? Modeling the costs and outcomes of antimicrobial catheter use. Am. J. Infect. Control. 31:2003;1-8
    • (2003) Am. J. Infect. Control , vol.31 , pp. 1-8
    • Marciante, K.D.1    Veenstra, D.L.2    Lipsky, B.A.3    Saint, S.4
  • 11
    • 0035574799 scopus 로고    scopus 로고
    • Antibiotic releasing urethane polymers for prevention of catheter related infections
    • Marconi W., Francolini I., Piozzi A., Di Rosa R. Antibiotic releasing urethane polymers for prevention of catheter related infections. Bioact. Compat. Polym. 16:2001;393-407
    • (2001) Bioact. Compat. Polym. , vol.16 , pp. 393-407
    • Marconi, W.1    Francolini, I.2    Piozzi, A.3    Di Rosa, R.4
  • 12
    • 0030250230 scopus 로고    scopus 로고
    • New polyurethane compositions able to bond high amounts of both albumin and heparin. II: Copolymers and polymer blends
    • Marconi W., Galloppa A., Martinelli A., Piozzi A. New polyurethane compositions able to bond high amounts of both albumin and heparin. II: Copolymers and polymer blends. Biomaterials. 17:1996;1795-1802
    • (1996) Biomaterials , vol.17 , pp. 1795-1802
    • Marconi, W.1    Galloppa, A.2    Martinelli, A.3    Piozzi, A.4
  • 14
    • 0031940769 scopus 로고    scopus 로고
    • Antimicrobial durability and rare ultrastructural colonization of indwelling central catheters coated with minocycline and rifampin
    • Raad I.I., Darouiche R.O., Hachem R., Abi-Said D., Safar H., Darnule T., Mansouri M., Morck D. Antimicrobial durability and rare ultrastructural colonization of indwelling central catheters coated with minocycline and rifampin. Crit. Care Med. 26:1998;219-224
    • (1998) Crit. Care Med. , vol.26 , pp. 219-224
    • Raad, I.I.1    Darouiche, R.O.2    Hachem, R.3    Abi-Said, D.4    Safar, H.5    Darnule, T.6    Mansouri, M.7    Morck, D.8
  • 15
    • 0033802325 scopus 로고    scopus 로고
    • Evaluation of antiseptic central venous catheters for prevention of catheter-related infection in intensive care unit patients
    • Sheng W., Ko W., Wang J., Chang S., Hsueh P., Luh K. Evaluation of antiseptic central venous catheters for prevention of catheter-related infection in intensive care unit patients. Diagn. Microbiol. Infect. Dis. 38:2000;1-5
    • (2000) Diagn. Microbiol. Infect. Dis. , vol.38 , pp. 1-5
    • Sheng, W.1    Ko, W.2    Wang, J.3    Chang, S.4    Hsueh, P.5    Luh, K.6
  • 16
    • 0024339495 scopus 로고
    • Efficacy of dicloxacillin-coated polyurethane catheters in preventing subcutaneous Staphylococcus aureus infection in mice
    • Sherertz R.J., Forman D.M., Solomon D.D. Efficacy of dicloxacillin-coated polyurethane catheters in preventing subcutaneous Staphylococcus aureus infection in mice. Antimicrob. Agents Chemother. 33:1989;1174-1178
    • (1989) Antimicrob. Agents Chemother. , vol.33 , pp. 1174-1178
    • Sherertz, R.J.1    Forman, D.M.2    Solomon, D.D.3
  • 17


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.