Electromagnetic interference on pacemakers

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT; ARTIFICIAL HEART PACEMAKER; AUTOMATIC CARDIOVERSION; CATHETER ABLATION; CAUTERIZATION; ELECTROMAGNETIC FIELD; EXERCISE; EXTRACORPOREAL LITHOTRIPSY; FOLLOW UP; HEART PACING; HUMAN; INFORMATION SYSTEM; MAGNETIC AND ELECTROMAGNETIC EQUIPMENT; MOBILE PHONE; MONITOR; NUCLEAR MAGNETIC RESONANCE IMAGING; PECTORAL MUSCLE; RADIOTHERAPY; REVIEW; TRANSCUTANEOUS NERVE STIMULATION;

EID: 3242663280     PISSN: 09726292     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (31)

References (27)
  • 1
    • 0019813313 scopus 로고
    • Pacemaker malfunction following transthoracic countershock
    • Das G, Eaton J. Pacemaker malfunction following transthoracic countershock. PACE 1981; 4: 487-90.
    • (1981) PACE , vol.4 , pp. 487-490
    • Das, G.1    Eaton, J.2
  • 2
    • 0028798688 scopus 로고
    • Transthoracic DC shock may represent a serious hazard in pacemaker dependent patients
    • Altamura G, Bianconi L, Lo Bianco F, et al. Transthoracic DC shock may represent a serious hazard in pacemaker dependent patients. PACE 1995; 18: 194-8.
    • (1995) PACE , vol.18 , pp. 194-198
    • Altamura, G.1    Bianconi, L.2    Lo Bianco, F.3
  • 3
    • 0019813316 scopus 로고
    • Pacemaker failure following external defibrillation
    • Gould L, Patel S, Gomez GI, et al. Pacemaker failure following external defibrillation. PACE 1981; 4: 575-7.
    • (1981) PACE , vol.4 , pp. 575-577
    • Gould, L.1    Patel, S.2    Gomez, G.I.3
  • 4
    • 0034130971 scopus 로고    scopus 로고
    • Safety of pacemaker implantation prior to radiofrequency ablation of atrioventricular junction in a single session procedure
    • Proclemer A, Facchin D, Pagnutti C, et al. Safety of pacemaker implantation prior to radiofrequency ablation of atrioventricular junction in a single session procedure. PACE 2000; 23: 998-1002.
    • (2000) PACE , vol.23 , pp. 998-1002
    • Proclemer, A.1    Facchin, D.2    Pagnutti, C.3
  • 5
    • 0029022175 scopus 로고
    • Pacemaker function during radiofrequency catheter ablation
    • Pfeiffer B, Tebbenjohanns J, Schumacher B, et al. Pacemaker function during radiofrequency catheter ablation. PACE 1995; 18: 1037-44.
    • (1995) PACE , vol.18 , pp. 1037-1044
    • Pfeiffer, B.1    Tebbenjohanns, J.2    Schumacher, B.3
  • 6
    • 0021740872 scopus 로고
    • Interference in pacemakers
    • Irnich W. Interference in pacemakers. PACE 1984; 7: 1021-1048.
    • (1984) PACE , vol.7 , pp. 1021-1048
    • Irnich, W.1
  • 7
    • 0031809709 scopus 로고    scopus 로고
    • Use of an ultrasonic scalpel as an alternative to electrocautery in patients with pacemakers
    • Epstein MR, Mayer JE, Duncan BW. Use of an ultrasonic scalpel as an alternative to electrocautery in patients with pacemakers. Ann Thorac Surg 1998; 65: 1802-4.
    • (1998) Ann. Thorac. Surg. , vol.65 , pp. 1802-1804
    • Epstein, M.R.1    Mayer, J.E.2    Duncan, B.W.3
  • 8
    • 0020638735 scopus 로고
    • The effects of nuclear magnetic resonance on patients with cardiac pacemaker
    • Pavlicek W, Geisinger M, Castle L, et al. The effects of nuclear magnetic resonance on patients with cardiac pacemaker. Radiology 1983; 147: 149-153.
    • (1983) Radiology , vol.147 , pp. 149-153
    • Pavlicek, W.1    Geisinger, M.2    Castle, L.3
  • 9
    • 0027475037 scopus 로고
    • Nuclear magnetic resonance imaging in a patient with a pacemaker: Case report
    • Inbar S, Larson J, Burt T, et al. Nuclear magnetic resonance imaging in a patient with a pacemaker: case report. Am J Med Sci 1993; 305: 174-5.
    • (1993) Am. J. Med. Sci. , vol.305 , pp. 174-175
    • Inbar, S.1    Larson, J.2    Burt, T.3
  • 10
    • 0035030124 scopus 로고    scopus 로고
    • Interference with cardiac pacemakers by magnetic resonance imaging: Are there irreversible changes at 0.5 Tesla?
    • Vahlhaus C, Somner T, Lewalter T, et al. Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla? PACE 2001; 24: 489-95.
    • (2001) PACE , vol.24 , pp. 489-495
    • Vahlhaus, C.1    Somner, T.2    Lewalter, T.3
  • 11
    • 0023253185 scopus 로고
    • Effect of 1.5 Tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers
    • Hayes DL, Holmes DR, Gray JE, et al. Effect of 1.5 Tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers. J Am Coll Cardiol 1987; 10: 782-786.
    • (1987) J. Am. Coll. Cardiol. , vol.10 , pp. 782-786
    • Hayes, D.L.1    Holmes, D.R.2    Gray, J.E.3
  • 12
    • 0030931926 scopus 로고    scopus 로고
    • Effects of magnetic resonance imaging on cardiac pacemakers and electrodes
    • Achenbach S, Moshage W, Diem B, et al. Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. Am Heart J 1997; 134: 467-73.
    • (1997) Am. Heart J. , vol.134 , pp. 467-473
    • Achenbach, S.1    Moshage, W.2    Diem, B.3
  • 13
    • 3242700917 scopus 로고    scopus 로고
    • Environmental effects on cardiac pacing systems
    • Kusumoto FM, Golschlager N, eds. Philadelphia, PA: Lippincott Williams and Wilkins
    • Kusumoto FM, Pedersen S, Golschlager N. Environmental effects on cardiac pacing systems. In: Kusumoto FM, Golschlager N, eds. Cardiac pacing for the clinician. Philadelphia, PA: Lippincott Williams and Wilkins, 2001: 377-94.
    • (2001) Cardiac Pacing for the Clinician , pp. 377-394
    • Kusumoto, F.M.1    Pedersen, S.2    Golschlager, N.3
  • 14
    • 0022809728 scopus 로고
    • Runaway atrioventricular sequential pacemaker after radiation therapy
    • Lee RW, Huang SK, Mechling E, et al. Runaway atrioventricular sequential pacemaker after radiation therapy. Am J Med 1986; 81: 883-86.
    • (1986) Am. J. Med. , vol.81 , pp. 883-886
    • Lee, R.W.1    Huang, S.K.2    Mechling, E.3
  • 15
    • 0025089624 scopus 로고
    • Monitoring the radiation dose to a multiprogrammable pacemaker during radical radiation therapy: A case report
    • Muller Runkel R, Orswolini G, Kalokhe UP. Monitoring the radiation dose to a multiprogrammable pacemaker during radical radiation therapy: a case report. PACE 1990; 12: 1466-70.
    • (1990) PACE , vol.12 , pp. 1466-1470
    • Muller Runkel, R.1    Orswolini, G.2    Kalokhe, U.P.3
  • 16
    • 0031984219 scopus 로고    scopus 로고
    • Radiotherapy in patients with cardiac pacemakers
    • Last A. Radiotherapy in patients with cardiac pacemakers. Br J Radiol 1998; 71: 4-10.
    • (1998) Br. J. Radiol. , vol.71 , pp. 4-10
    • Last, A.1
  • 17
    • 0028219333 scopus 로고
    • Pacemaker failure induced by radiotherapy
    • Souliman SK, Christie J. Pacemaker failure induced by radiotherapy. PACE 1994; 17: 270-3.
    • (1994) PACE , vol.17 , pp. 270-273
    • Souliman, S.K.1    Christie, J.2
  • 18
    • 0029045473 scopus 로고
    • Do European GSM mobile cellular phones pose a potential risk to pacemaker patients?
    • Barbaro V, Bartolini P, Donato A, et al. Do European GSM mobile cellular phones pose a potential risk to pacemaker patients? PACE 1995; 18: 1218-24.
    • (1995) PACE , vol.18 , pp. 1218-1224
    • Barbaro, V.1    Bartolini, P.2    Donato, A.3
  • 19
    • 0030765826 scopus 로고    scopus 로고
    • Influence of digital and analogue cellular telephones on implanted pacemakers
    • Altamura G, Toscano S, Gentulicci G, et al. Influence of digital and analogue cellular telephones on implanted pacemakers. Eur Heart J 1997; 18: 1632-41.
    • (1997) Eur. Heart J. , vol.18 , pp. 1632-1641
    • Altamura, G.1    Toscano, S.2    Gentulicci, G.3
  • 20
    • 0030925632 scopus 로고    scopus 로고
    • Interference with cardiac pacemakers by cellular telephones
    • Hayes DL, Wang PJ, Reynolds DW, et al. Interference with cardiac pacemakers by cellular telephones. N Eng J Med 1997; 336: 1473-9.
    • (1997) N. Eng. J. Med. , vol.336 , pp. 1473-1479
    • Hayes, D.L.1    Wang, P.J.2    Reynolds, D.W.3
  • 21
    • 0023947355 scopus 로고
    • Can transcutaneous electrical nerve stimulation be safely used in patients with permanent pacemakers?
    • Rasmussen MJ, Hayes DL, Vliestra RE, et al. Can transcutaneous electrical nerve stimulation be safely used in patients with permanent pacemakers? Mayo Clin Proc 1988; 63: 443.
    • (1988) Mayo Clin. Proc. , vol.63 , pp. 443
    • Rasmussen, M.J.1    Hayes, D.L.2    Vliestra, R.E.3
  • 22
    • 0031753473 scopus 로고    scopus 로고
    • Hospital pager systems may cause interference with pacemaker telemetry
    • Duru F, Lauber P, Klaus G, et al. Hospital pager systems may cause interference with pacemaker telemetry. PACE 1998; 21: 2353-9.
    • (1998) PACE , vol.21 , pp. 2353-2539
    • Duru, F.1    Lauber, P.2    Klaus, G.3
  • 23
  • 24
    • 8044250277 scopus 로고    scopus 로고
    • Inappropriate rate change in minute ventilation rate responsive pacemakers due to interference by cardiac monitors
    • Chew EW, Troughear RH, Kuchar DL, et al. Inappropriate rate change in minute ventilation rate responsive pacemakers due to interference by cardiac monitors. PACE 1997; 20: 276-82.
    • (1997) PACE , vol.20 , pp. 276-282
    • Chew, E.W.1    Troughear, R.H.2    Kuchar, D.L.3
  • 25
    • 0031714598 scopus 로고    scopus 로고
    • Study of pacemaker and implantable cardioverter defibrillator triggering by electronic article surveillance devices
    • McIvor ME, Reddinger J, Floden E, et al. Study of pacemaker and implantable cardioverter defibrillator triggering by electronic article surveillance devices. PACE 1998; 21: 1847-61.
    • (1998) PACE , vol.21 , pp. 1847-1861
    • McIvor, M.E.1    Reddinger, J.2    Floden, E.3
  • 26
    • 0035186645 scopus 로고    scopus 로고
    • Pacemakers and store security devices
    • Harthorne JW. Pacemakers and store security devices. Cardiol Rev 2001; 9: 10-17.
    • (2001) Cardiol. Rev. , vol.9 , pp. 10-17
    • Harthorne, J.W.1
  • 27
    • 0026499215 scopus 로고
    • Testing work environments for electromagnetic interference
    • Marco D, Eisinger G, Hayes DL. Testing work environments for electromagnetic interference. PACE 1992; 15:2016-22.
    • (1992) PACE , vol.15 , pp. 2016-2022
    • Marco, D.1    Eisinger, G.2    Hayes, D.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.