메뉴 건너뛰기




Volumn 19, Issue 7, 2004, Pages 1835-1841

Clinical validation of glucose pump test (GPT) compared with ultrasound dilution technology in arteriovenous graft surveillance

Author keywords

Colour Doppler ultrasound; Haemodialysis; Ultrasound dilution technology; Vascular access

Indexed keywords

ARTICLE; CLINICAL ARTICLE; COLOR ULTRASOUND FLOWMETRY; CONTROLLED STUDY; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST; DIAGNOSTIC VALUE; DISEASE SEVERITY; ECHOGRAPHY; GLUCOSE INFUSION; GRAFT OCCLUSION; GRAFT PATENCY; HEMODIALYSIS; HEMODYNAMICS; HIGH RISK PATIENT; HUMAN; INFUSION PUMP; INTERMETHOD COMPARISON; LABORATORY DIAGNOSIS; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; STATISTICAL ANALYSIS; STATISTICAL SIGNIFICANCE; VASCULAR ACCESS;

EID: 3242661623     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/ndt/gfh292     Document Type: Article
Times cited : (14)

References (24)
  • 2
    • 0035228229 scopus 로고    scopus 로고
    • K/DOQI Clinical Practice Guidelines for Vascular Access, 2000. National Kidney Foundation
    • National Kidney Foundation
    • National Kidney Foundation. K/DOQI Clinical Practice Guidelines for Vascular Access, 2000. National Kidney Foundation. Am J Kidney Dis 2001; 37: S137-S181
    • (2001) Am. J. Kidney Dis. , vol.37
  • 3
    • 0024467709 scopus 로고
    • Prevention of hemodialysis fistula thrombosis: Early detection of venous stenosis
    • Schwab AB, Raymond JR, Saled M et al. Prevention of hemodialysis fistula thrombosis: early detection of venous stenosis. Kidney Int 1989; 36: 707-711
    • (1989) Kidney Int. , vol.36 , pp. 707-711
    • Schwab, A.B.1    Raymond, J.R.2    Saled, M.3
  • 5
    • 0024429402 scopus 로고
    • Duplex ultrasound scanning in the assesment of arteriovenous fistulas created for hemodialysis access: Comparison with digital subtraction angiography
    • Tordoir JHM, de Bruin HG, Hoeneveld H et al. Duplex ultrasound scanning in the assesment of arteriovenous fistulas created for hemodialysis access: comparison with digital subtraction angiography. J Vasc Surg 1989; 10: 122-128
    • (1989) J. Vasc. Surg. , vol.10 , pp. 122-128
    • Tordoir, J.H.M.1    de Bruin, H.G.2    Hoeneveld, H.3
  • 6
    • 0031782772 scopus 로고    scopus 로고
    • Hemodialysis access graft stenosis: US detection
    • Robbin ML, Oser RF, Allon M et al. Hemodialysis access graft stenosis: US detection. Radiology 1998; 208: 655-661
    • (1998) Radiology , vol.208 , pp. 655-661
    • Robbin, M.L.1    Oser, R.F.2    Allon, M.3
  • 7
    • 0031950466 scopus 로고    scopus 로고
    • Accuracy of Doppler ultrasound in diagnosing anatomic stenosis of hemodialysis arteriovenous access as compared with fistulography
    • Gadallah MF, Paulson WD, Vickers B, Work J. Accuracy of Doppler ultrasound in diagnosing anatomic stenosis of hemodialysis arteriovenous access as compared with fistulography. Am J Kidney Dis 1998; 32: 273-277
    • (1998) Am. J. Kidney Dis. , vol.32 , pp. 273-277
    • Gadallah, M.F.1    Paulson, W.D.2    Vickers, B.3    Work, J.4
  • 8
    • 0026539960 scopus 로고
    • The effect of Doppler flow screening studies and elective revision on dialysis access failure
    • Sands J, Young S, Miranda C. The effect of Doppler flow screening studies and elective revision on dialysis access failure. ASAIO J 1992; 38: M524-M527
    • (1992) ASAIO J. , vol.38
    • Sands, J.1    Young, S.2    Miranda, C.3
  • 9
    • 0026728658 scopus 로고
    • Forecasting thrombosis of vascular access with Doppler color flow imaging
    • Strauch BS, O'Connell RS, Geoly KL. Forecasting thrombosis of vascular access with Doppler color flow imaging. Am J Kidney Dis 1992; 19: 554-557
    • (1992) Am. J. Kidney Dis. , vol.19 , pp. 554-557
    • Strauch, B.S.1    O'Connell, R.S.2    Geoly, K.L.3
  • 10
    • 0029952571 scopus 로고    scopus 로고
    • Duplex referral of hemodialysis access for percutaneous balloon angioplasty
    • Miranda CL, Sands JJ. Duplex referral of hemodialysis access for percutaneous balloon angioplasty. J Vasc Technol 1996; 20: 99-103
    • (1996) J. Vasc. Technol. , vol.20 , pp. 99-103
    • Miranda, C.L.1    Sands, J.J.2
  • 11
    • 0029048487 scopus 로고
    • Theory and validation of access flow measurement by dilution technique during hemodialysis
    • Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 1995; 48: 244-250
    • (1995) Kidney Int. , vol.48 , pp. 244-250
    • Krivitski, N.M.1
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0037228476 scopus 로고    scopus 로고
    • Native arteriovenous fistula blood flow and resistance during hemodialysis
    • Polkinghorne KR, Atkins RC, Kerr PG. Native arteriovenous fistula blood flow and resistance during hemodialysis. Am J Kidney Dis 2003; 41: 132-139
    • (2003) Am. J. Kidney Dis. , vol.41 , pp. 132-139
    • Polkinghorne, K.R.1    Atkins, R.C.2    Kerr, P.G.3
  • 14
    • 0002586831 scopus 로고
    • Estimations of cardiac output and central blood volume by die dilution
    • Dow P. Estimations of cardiac output and central blood volume by die dilution. Physiol Rev 1956; 36: 77
    • (1956) Physiol. Rev. , vol.36 , pp. 77
    • Dow, P.1
  • 15
    • 0017311220 scopus 로고
    • Radiotracer method for nonsurgical measurement of blood flow in bovine graft arteriovenous fistulas
    • Gottlieb S, Garcia E, Cold SB, Vanderwerf BA. Radiotracer method for nonsurgical measurement of blood flow in bovine graft arteriovenous fistulas. Proc Dial Transplant Forum 1976; 6: 107-108
    • (1976) Proc. Dial. Transplant. Forum , vol.6 , pp. 107-108
    • Gottlieb, S.1    Garcia, E.2    Cold, S.B.3    Vanderwerf, B.A.4
  • 16
    • 0034099470 scopus 로고    scopus 로고
    • Glucose infusion test: A new screening test for vascular access recirculation
    • Magnasco A, Alloatti S, Bonfant et al. Glucose infusion test: a new screening test for vascular access recirculation. Kidney Int 2000; 57: 2123-2128
    • (2000) Kidney Int. , vol.57 , pp. 2123-2128
    • Magnasco, A.1    Alloatti, S.2    Bonfant, A.3
  • 17
    • 0034811908 scopus 로고    scopus 로고
    • Use of vascular access blood flow to evaluate vascular access
    • Paulson WD, Sunanda JR, Work J. Use of vascular access blood flow to evaluate vascular access. Am J Kidney Dis 2001; 38: 916
    • (2001) Am. J. Kidney Dis. , vol.38 , pp. 916
    • Paulson, W.D.1    Sunanda, J.R.2    Work, J.3
  • 19
    • 0038468806 scopus 로고    scopus 로고
    • A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts
    • Ram SJ, Work J, Caldito GC et al. A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts. Kidney Int 2003; 64: 272-280
    • (2003) Kidney Int. , vol.64 , pp. 272-280
    • Ram, S.J.1    Work, J.2    Caldito, G.C.3
  • 20
    • 0141566810 scopus 로고    scopus 로고
    • Regular monitoring of access flow compared with monitoring of venous pressure fails to improve graft survival
    • Moist LM, Churchill DN, House AA et al. Regular monitoring of access flow compared with monitoring of venous pressure fails to improve graft survival. J Am Soc Nephrol 2003; 14: 2645-2653
    • (2003) J. Am. Soc. Nephrol. , vol.14 , pp. 2645-2653
    • Moist, L.M.1    Churchill, D.N.2    House, A.A.3
  • 21
    • 0038346024 scopus 로고    scopus 로고
    • Pittfalls of the glucose pump test for access flow measurement
    • Krivitski NM. Pittfalls of the glucose pump test for access flow measurement. Nephrol Dial Transplant 2003; 18: 1230
    • (2003) Nephrol. Dial. Transplant. , vol.18 , pp. 1230
    • Krivitski, N.M.1
  • 22
    • 0141508882 scopus 로고    scopus 로고
    • In vivo validation of glucose pump test for measurement of hemodialysis access flow
    • Ram SJ, Magnasco A, Steven AJ et al. In vivo validation of glucose pump test for measurement of hemodialysis access flow. Am J Kidney Dis 2003; 42: 752-760
    • (2003) Am. J. Kidney Dis. , vol.42 , pp. 752-760
    • Ram, S.J.1    Magnasco, A.2    Steven, A.J.3
  • 23
    • 0030372749 scopus 로고    scopus 로고
    • Access flow measurements in hemodialysis patients: In vivo validation of an ultrasound dilution technique
    • Bosman PJ, Boereboom FT, Eikelboom BC et al. Access flow measurements in hemodialysis patients: in vivo validation of an ultrasound dilution technique. J Am Soc Nephrol 1996; 7: 966-969
    • (1996) J. Am. Soc. Nephrol. , vol.7 , pp. 966-969
    • Bosman, P.J.1    Boereboom, F.T.2    Eikelboom, B.C.3
  • 24
    • 0037034061 scopus 로고    scopus 로고
    • Underestimation of access flow by ultrasound dilution flow measurements
    • Bos C, Smits JH, Zijlstra JJ et al. Underestimation of access flow by ultrasound dilution flow measurements. Phys Med Biol 2002; 47: 481-489
    • (2002) Phys. Med. Biol. , vol.47 , pp. 481-489
    • Bos, C.1    Smits, J.H.2    Zijlstra, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.