메뉴 건너뛰기




Volumn 30, Issue 3-4, 2004, Pages 467-470

Measurement of blood viscosity using a pressure-scanning capillary viscometer

Author keywords

Blood; Capillary viscometer; Pressure; Shear rate; Viscosity

Indexed keywords

EDETIC ACID; HEPARIN; WATER;

EID: 3242659785     PISSN: 13860291     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (16)

References (6)
  • 1
    • 0022883918 scopus 로고
    • Evaulation of a new dynamic viscometer for measuring the viscosity of whole blood and plasma
    • W.L. Chandler and G. Schmer, Evaulation of a new dynamic viscometer for measuring the viscosity of whole blood and plasma, Clin. Chem. 32 (1986), 505-507.
    • (1986) Clin. Chem. , vol.32 , pp. 505-507
    • Chandler, W.L.1    Schmer, G.2
  • 2
    • 0014447480 scopus 로고
    • Blood rheology in pathogenesis of the coronary heart deseases
    • L. Dintenfass, Blood rheology in pathogenesis of the coronary heart deseases, Am. Heart J. 77 (1969), 139-147.
    • (1969) Am. Heart J. , vol.77 , pp. 139-147
    • Dintenfass, L.1
  • 3
    • 0030973450 scopus 로고    scopus 로고
    • Whole blood viscosity, blood pressure and cardiovascular risk factors in healthy blood donors
    • E. Possum, A. Høieggen and A. Moan, Whole blood viscosity, blood pressure and cardiovascular risk factors in healthy blood donors, Blood Press. 6 (1997), 161-165.
    • (1997) Blood Press. , vol.6 , pp. 161-165
    • Possum, E.1    Høieggen, A.2    Moan, A.3
  • 4
    • 0006285772 scopus 로고
    • Protective adaptation hypothesis as the etiology of atherosclerosis
    • K.R. Kensey and Y.I. Cho, Protective adaptation hypothesis as the etiology of atherosclerosis, J. Invasive Cardiol. 4 (1992), 448-458.
    • (1992) J. Invasive Cardiol. , vol.4 , pp. 448-458
    • Kensey, K.R.1    Cho, Y.I.2
  • 5
    • 0025139969 scopus 로고
    • Influence of blood with drawal and Anticoagulant on clotting activity, hemotologic data, and certain rheologic measurements
    • W.H. Reinhart, A. Haeberli, J. Stark and P.W. Straub, Influence of blood with drawal and Anticoagulant on clotting activity, hemotologic data, and certain rheologic measurements, J. Lab. Clinical Med. 115 (1990), 98-103.
    • (1990) J. Lab. Clinical Med. , vol.115 , pp. 98-103
    • Reinhart, W.H.1    Haeberli, A.2    Stark, J.3    Straub, P.W.4
  • 6
    • 0036122893 scopus 로고    scopus 로고
    • A new mass-detecting capillary viscometer
    • S. Shin and D.Y. Keum, A new mass-detecting capillary viscometer, Biosensor and Bioelectronics 17 (2002), 383-388.
    • (2002) Biosensor and Bioelectronics , vol.17 , pp. 383-388
    • Shin, S.1    Keum, D.Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.