메뉴 건너뛰기




Volumn 43, Issue 2, 2006, Pages 402-405

T-banding: A technique for flow reduction of a hyperfunctioning arteriovenous fistula

Author keywords

[No Author keywords available]

Indexed keywords

ANASTOMOSIS; ANEURYSM; ARTERIOVENOUS FISTULA; ARTICLE; CLINICAL ARTICLE; FLOW RATE; FOLLOW UP; HEART FAILURE; HUMAN; PRIORITY JOURNAL; SHUNTING; STENOSIS; T BANDING; TECHNIQUE; TIME SERIES ANALYSIS;

EID: 32344444765     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvs.2005.11.047     Document Type: Article
Times cited : (36)

References (17)
  • 1
    • 0023915169 scopus 로고
    • Treatment of ischemia due to "steal" by arteriovenous fistula with distal artery ligation and revascularization
    • H. Schanzer, M. Schwartz, E. Harrington, M. Haimov Treatment of ischemia due to "steal" by arteriovenous fistula with distal artery ligation and revascularization J Vasc Surg 7 1988 770 773
    • (1988) J Vasc Surg , vol.7 , pp. 770-773
    • Schanzer, H.1    Schwartz, M.2    Harrington, E.3    Haimov, M.4
  • 2
    • 9344271498 scopus 로고    scopus 로고
    • Effect of surgical banding of a high-flow fistula on access flow and cardiac output: Intraoperative and long-term measurements
    • B.M. Murray, S. Rajczak, A. Herman, D. Leary Effect of surgical banding of a high-flow fistula on access flow and cardiac output intraoperative and long-term measurements Am J Kidney Dis 44 2004 1090 1096
    • (2004) Am J Kidney Dis , vol.44 , pp. 1090-1096
    • Murray, B.M.1    Rajczak, S.2    Herman, A.3    Leary, D.4
  • 4
    • 0028087874 scopus 로고
    • Banding a hemodialysis arteriovenous fistula to decrease blood flow and resolve high output cardiac failure: Report of a case
    • S. Isoda, H. Kajiwara, J. Kondo, A. Matsumoto Banding a hemodialysis arteriovenous fistula to decrease blood flow and resolve high output cardiac failure report of a case Surg Today 24 1994 734 736
    • (1994) Surg Today , vol.24 , pp. 734-736
    • Isoda, S.1    Kajiwara, H.2    Kondo, J.3    Matsumoto, A.4
  • 5
    • 0030955367 scopus 로고    scopus 로고
    • Distal revascularization-interval ligation for limb salvage and maintenance of dialysis access in ischemic steal syndrome
    • S.S. Berman, A.T. Gentile, M.H. Glickman, J.L. Mills, R.L. Hurwitz, A. Westerband Distal revascularization-interval ligation for limb salvage and maintenance of dialysis access in ischemic steal syndrome J Vasc Surg 26 1997 393 402
    • (1997) J Vasc Surg , vol.26 , pp. 393-402
    • Berman, S.S.1    Gentile, A.T.2    Glickman, M.H.3    Mills, J.L.4    Hurwitz, R.L.5    Westerband, A.6
  • 6
    • 1542741214 scopus 로고    scopus 로고
    • Management of steal syndrome resulting from dialysis access
    • H. Schanzer, D. Eisenberg Management of steal syndrome resulting from dialysis access Semin Vasc Surg 17 2004 45 49
    • (2004) Semin Vasc Surg , vol.17 , pp. 45-49
    • Schanzer, H.1    Eisenberg, D.2
  • 7
    • 0031845731 scopus 로고    scopus 로고
    • Incidence and characteristics of patients with hand ischemia after a hemodialysis access procedure
    • A.H. Morsy, M. Kulbaski, C. Chen, H. Isiklar, A.B. Lumsden Incidence and characteristics of patients with hand ischemia after a hemodialysis access procedure J Surg Res 74 1998 8 10
    • (1998) J Surg Res , vol.74 , pp. 8-10
    • Morsy, A.H.1    Kulbaski, M.2    Chen, C.3    Isiklar, H.4    Lumsden, A.B.5
  • 8
    • 0032773170 scopus 로고    scopus 로고
    • Management of dialysis access-associated steal syndrome: Use of intraoperative duplex ultrasound scanning for optimal flow reduction
    • D. Shemesh, N.J. Mabjeesh, H.B. Abramowitz Management of dialysis access-associated steal syndrome use of intraoperative duplex ultrasound scanning for optimal flow reduction J Vasc Surg 30 1999 193 195
    • (1999) J Vasc Surg , vol.30 , pp. 193-195
    • Shemesh, D.1    Mabjeesh, N.J.2    Abramowitz, H.B.3
  • 9
    • 0036676062 scopus 로고    scopus 로고
    • Distal revascularization-interval ligation: A durable and effective treatment for ischemic steal syndrome after hemodialysis access
    • R.C. Knox, S.S. Berman, J.D. Hughes, A.T. Gentile, J.L. Mills Distal revascularization-interval ligation a durable and effective treatment for ischemic steal syndrome after hemodialysis access J Vasc Surg 36 2002 250 255
    • (2002) J Vasc Surg , vol.36 , pp. 250-255
    • Knox, R.C.1    Berman, S.S.2    Hughes, J.D.3    Gentile, A.T.4    Mills, J.L.5
  • 10
    • 0027181743 scopus 로고
    • The surgical management of high-output cardiac failure due to arteriovenous haemodialysis fistulae
    • I. Khalil, P. Sfeir The surgical management of high-output cardiac failure due to arteriovenous haemodialysis fistulae Eur J Vasc Surg 7 1993 577 579
    • (1993) Eur J Vasc Surg , vol.7 , pp. 577-579
    • Khalil, I.1    Sfeir, P.2
  • 11
    • 0034063316 scopus 로고    scopus 로고
    • Distal revascularization-interval ligation for maintenance of dialysis access and restoration of distal perfusion in ischemic steal syndrome
    • C.L. Wixon, J.L. Mills Sr, S.S. Berman Distal revascularization-interval ligation for maintenance of dialysis access and restoration of distal perfusion in ischemic steal syndrome Semin Vasc Surg 13 2000 77 82
    • (2000) Semin Vasc Surg , vol.13 , pp. 77-82
    • Wixon, C.L.1    Mills Sr., J.L.2    Berman, S.S.3
  • 12
    • 0015379043 scopus 로고
    • Heart failure as a complication of hemodialysis arteriovenous fistula
    • D.J. Ahearn, J.F. Maher Heart failure as a complication of hemodialysis arteriovenous fistula Ann Intern Med 77 1972 201 204
    • (1972) Ann Intern Med , vol.77 , pp. 201-204
    • Ahearn, D.J.1    Maher, J.F.2
  • 13
    • 0016754678 scopus 로고
    • Banding of arteriovenous dialysis fistulas to correct high-output cardiac failure
    • C.B. Anderson, M.A. Groce Banding of arteriovenous dialysis fistulas to correct high-output cardiac failure Surgery 78 1975 552 554
    • (1975) Surgery , vol.78 , pp. 552-554
    • Anderson, C.B.1    Groce, M.A.2
  • 14
    • 0026079823 scopus 로고
    • Management of dialysis-associated steal syndrome complicating upper extremity arteriovenous fistulas: Use of intraoperative digital photoplethysmography
    • M.D. Odland, P.H. Kelly, A.L. Ney, R.C. Andersen, M.P. Bubrick Management of dialysis-associated steal syndrome complicating upper extremity arteriovenous fistulas use of intraoperative digital photoplethysmography Surgery 110 1991 664 669
    • (1991) Surgery , vol.110 , pp. 664-669
    • Odland, M.D.1    Kelly, P.H.2    Ney, A.L.3    Andersen, R.C.4    Bubrick, M.P.5
  • 15
    • 84907128638 scopus 로고
    • Banding of a PTFE hemodialysis fistula in the treatment of steal syndrome
    • A. Ebeid, H.J. Saranchak Banding of a PTFE hemodialysis fistula in the treatment of steal syndrome Clin Exp Dial Apheresis 5 1981 251 257
    • (1981) Clin Exp Dial Apheresis , vol.5 , pp. 251-257
    • Ebeid, A.1    Saranchak, H.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.