메뉴 건너뛰기




Volumn 27, Issue 2, 2006, Pages 88-92

Ankle alignment on lateral radiographs. Part 2: Reliability and validity of measures

Author keywords

Ankle Alignment; Radiographic Measurement

Indexed keywords

ADOLESCENT; ADULT; AGED; ANKLE RADIOGRAPHY; ARTICLE; CADAVER; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HUMAN; MALE; MORPHOLOGY; OSTEOARTHRITIS; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RELIABILITY; REPRODUCIBILITY; SUBLUXATION; SURFACE PROPERTY; TALUS; TIBIA SHAFT;

EID: 32144453678     PISSN: 10711007     EISSN: None     Source Type: Journal    
DOI: 10.1177/107110070602700203     Document Type: Article
Times cited : (71)

References (8)
  • 1
    • 0034797957 scopus 로고    scopus 로고
    • Complications of total ankle replacement
    • Conti, SF; Wong, YS: Complications of total ankle replacement. Clin. Orthop. 391:105-114, 2001.
    • (2001) Clin. Orthop. , vol.391 , pp. 105-114
    • Conti, S.F.1    Wong, Y.S.2
  • 2
    • 0037225210 scopus 로고    scopus 로고
    • Perioperative complications of total ankle arthroplasty
    • Myerson, MS; Mroczek, K: Perioperative complications of total ankle arthroplasty. Foot Ankle Int. 24:17-21, 2003.
    • (2003) Foot Ankle Int. , vol.24 , pp. 17-21
    • Myerson, M.S.1    Mroczek, K.2
  • 4
    • 3042698012 scopus 로고    scopus 로고
    • The effect of Agility ankle prosthesis misalignment on the peri-ankle ligaments
    • Saltzman, CL; Tochigi, Y; Rudert, MJ; McIff, TE; Brown, TD: The effect of Agility ankle prosthesis misalignment on the peri-ankle ligaments. Clin. Orthop. 424:137-142, 2004.
    • (2004) Clin. Orthop. , vol.424 , pp. 137-142
    • Saltzman, C.L.1    Tochigi, Y.2    Rudert, M.J.3    McIff, T.E.4    Brown, T.D.5
  • 5
    • 0028874288 scopus 로고
    • Low tibial osteotomy for osteoarthritis of the ankle; results of a new operation in 18 patients
    • Takakura, Y; Tanaka, Y; Kumai, T; Tamai, S: Low tibial osteotomy for osteoarthritis of the ankle; results of a new operation in 18 patients. J. Bone Joint Surg. 77-B:50-54, 1995.
    • (1995) J. Bone Joint Surg. , vol.77 , pp. 50-54
    • Takakura, Y.1    Tanaka, Y.2    Kumai, T.3    Tamai, S.4
  • 6
    • 18944388388 scopus 로고    scopus 로고
    • Effect of implantation accuracy on functional range of motion of the Scandinavian Total Ankle Replacement
    • Tochigi, Y; Rudert, MJ; Brown, TD; McIff, TE; Saltzman, CL: Effect of implantation accuracy on functional range of motion of the Scandinavian Total Ankle Replacement. J. Bone Joint Surg. 87-B:736-740, 2005.
    • (2005) J. Bone Joint Surg. , vol.87 , pp. 736-740
    • Tochigi, Y.1    Rudert, M.J.2    Brown, T.D.3    McIff, T.E.4    Saltzman, C.L.5
  • 7
    • 85039357001 scopus 로고    scopus 로고
    • Tibial-Talar alignment on lateral radiographs: Part 1: Tolerance of measures to perturbations of ankle positioning
    • Accepted for publication
    • Tochigi, Y; Suh, J; Amendola, A; Pedersen, DR; Saltzman, CL: Tibial-Talar alignment on lateral radiographs: Part 1: tolerance of measures to perturbations of ankle positioning, Foot Ankle Int. (Accepted for publication 2005).
    • (2005) Foot Ankle Int.
    • Tochigi, Y.1    Suh, J.2    Amendola, A.3    Pedersen, D.R.4    Saltzman, C.L.5
  • 8
    • 0021659626 scopus 로고
    • The effect of simulated tibial deformities on the ankle joint during the gait cycle
    • Wagner, KS; Tarr, RR; Rensick, C; Sarmiento, A: The effect of simulated tibial deformities on the ankle joint during the gait cycle. Foot Ankle 5:131-141, 1984.
    • (1984) Foot Ankle , vol.5 , pp. 131-141
    • Wagner, K.S.1    Tarr, R.R.2    Rensick, C.3    Sarmiento, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.