메뉴 건너뛰기




Volumn 15, Issue 1, 2006, Pages 36-41

Temperature mapping of thermal ablation using MRI

Author keywords

Magnetic Resonance; Thermal ablation; Thermometry

Indexed keywords

BODY TEMPERATURE; CALCULATION; COOLING; CRYOSURGERY; DIFFUSION WEIGHTED IMAGING; FREEZING; HEATING; HYPERTHERMIC THERAPY; MATHEMATICAL MODEL; MINIMALLY INVASIVE SURGERY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT MONITORING; PHYSICS; PLOTS AND CURVES; PRIORITY JOURNAL; PROCESS MODEL; PROTON NUCLEAR MAGNETIC RESONANCE; REVIEW;

EID: 32144438907     PISSN: 13645706     EISSN: None     Source Type: Journal    
DOI: 10.1080/13645700500491005     Document Type: Review
Times cited : (21)

References (55)
  • 1
    • 0035116428 scopus 로고    scopus 로고
    • Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation
    • Botnar, R. M. and Steiner, P. and Dubno, B. and Erhart, P. and (2001) Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation. Journal of Magnetic Resonance Imaging, 13, pp. 437 - 44.
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , pp. 437-444
    • Botnar, R.M.1    Steiner, P.2    Dubno, B.3    Erhart, P.4
  • 3
    • 18544399516 scopus 로고    scopus 로고
    • Prostate cancer: MR imaging and thermometry during microwave thermal ablation-initial experience
    • Chen, J. C. and Moriarty, J. A. and Derbyshire, J. A. and Peters, R. D. and (2000) Prostate cancer: MR imaging and thermometry during microwave thermal ablation-initial experience. Radiology, 214, pp. 290 - 7.
    • (2000) Radiology , vol.214 , pp. 290-297
    • Chen, J.C.1    Moriarty, J.A.2    Derbyshire, J.A.3    Peters, R.D.4
  • 4
    • 0028910309 scopus 로고
    • Temperature-Dependence of Canine Brain-Tissue Diffusion-Coefficient Measured In-Vivo with Magnetic-Resonance Echo-Planar Imaging
    • MacFall, J. and Prescott, D. M. and Fullar, E. and Samulski, T. V. (1995) Temperature-Dependence of Canine Brain-Tissue Diffusion-Coefficient Measured In-Vivo with Magnetic-Resonance Echo-Planar Imaging. International Journal of Hyperthermia, 11, pp. 73 - 86.
    • (1995) International Journal of Hyperthermia , vol.11 , pp. 73-86
    • MacFall, J.1    Prescott, D.M.2    Fullar, E.3    Samulski, T.V.4
  • 5
    • 0031887746 scopus 로고    scopus 로고
    • MRI monitoring of interstitial microwave-induced heating and thermal lesions in rabbit brain in vivo
    • Moriarty, J. A. and Chen, J. C. and Purcell, C. M. and Ang, L. C. and (1998) MRI monitoring of interstitial microwave-induced heating and thermal lesions in rabbit brain in vivo. Jmri-Journal of Magnetic Resonance Imaging, 8, pp. 128 - 35.
    • (1998) Jmri-Journal of Magnetic Resonance Imaging , vol.8 , pp. 128-135
    • Moriarty, J.A.1    Chen, J.C.2    Purcell, C.M.3    Ang, L.C.4
  • 6
    • 0026188977 scopus 로고
    • Design of an automated temperature mapping system for ultrasound or microwave hyperthermia
    • Ryan, T. P. and Wikoff, R. P. and Hoopes, P. J. (1991) Design of an automated temperature mapping system for ultrasound or microwave hyperthermia. Journal of Biomedical Engineering, 13, pp. 348 - 54.
    • (1991) Journal of Biomedical Engineering , vol.13 , pp. 348-354
    • Ryan, T.P.1    Wikoff, R.P.2    Hoopes, P.J.3
  • 7
    • 0028941658 scopus 로고
    • Magnetic-Resonance-Imaging of Microwave-Induced Tissue Heating
    • Schwarzmaier, H. J. and Kahn, T. (1995) Magnetic-Resonance-Imaging of Microwave-Induced Tissue Heating. Magnetic Resonance in Medicine, 33, pp. 729 - 31.
    • (1995) Magnetic Resonance in Medicine , vol.33 , pp. 729-731
    • Schwarzmaier, H.J.1    Kahn, T.2
  • 8
    • 0034534760 scopus 로고    scopus 로고
    • Comparison of thermal damage calculated using magnetic resonance thermometry, with magnetic resonance imaging post-treatment and histology, after interstitial microwave thermal therapy of rabbit brain
    • Sherar, M. D. and Moriarty, J. A. and Kolios, M. C. and Chen, J. C. and (2000) Comparison of thermal damage calculated using magnetic resonance thermometry, with magnetic resonance imaging post-treatment and histology, after interstitial microwave thermal therapy of rabbit brain. Physics in Medicine and Biology, 45, pp. 3563 - 76.
    • (2000) Physics in Medicine and Biology , vol.45 , pp. 3563-3576
    • Sherar, M.D.1    Moriarty, J.A.2    Kolios, M.C.3    Chen, J.C.4
  • 9
    • 8044243593 scopus 로고    scopus 로고
    • Magnetic resonance imaging of temperature changes during interstitial microwave heating: A phantom study
    • Vitkin, I. A. and Moriarty, J. A. and Peters, R. D. and Kolios, M. C. and (1997) Magnetic resonance imaging of temperature changes during interstitial microwave heating: A phantom study. Medical Physics, 24, pp. 269 - 77.
    • (1997) Medical Physics , vol.24 , pp. 269-277
    • Vitkin, I.A.1    Moriarty, J.A.2    Peters, R.D.3    Kolios, M.C.4
  • 10
    • 0035172455 scopus 로고    scopus 로고
    • MRI study of immediate cell viability in focused ultrasound lesions in the rabbit brain
    • Chen, L. and Bouley, D. M. and Harris, B. T. and Butts, K. (2001) MRI study of immediate cell viability in focused ultrasound lesions in the rabbit brain. Journal of Magnetic Resonance Imaging, 13, pp. 23 - 30.
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , pp. 23-30
    • Chen, L.1    Bouley, D.M.2    Harris, B.T.3    Butts, K.4
  • 12
    • 0029958301 scopus 로고    scopus 로고
    • Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam
    • Chung, A. H. and Hynynen, K. and Colucci, V. and Oshio, K. and (1996) Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam. Magnetic Resonance in Medicine, 36, pp. 745 - 52.
    • (1996) Magnetic Resonance in Medicine , vol.36 , pp. 745-752
    • Chung, A.H.1    Hynynen, K.2    Colucci, V.3    Oshio, K.4
  • 13
    • 0032825054 scopus 로고    scopus 로고
    • Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging
    • Chung, A. H. and Jolesz, F. A. and Hynynen, K. (1999) Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging. Medical Physics, 26, pp. 2017 - 26.
    • (1999) Medical Physics , vol.26 , pp. 2017-2026
    • Chung, A.H.1    Jolesz, F.A.2    Hynynen, K.3
  • 15
    • 0032965735 scopus 로고    scopus 로고
    • Quantifying tissue damage due to focused ultrasound heating observed by MRI
    • Graham, S. J. and Chen, L. and Leitch, M. and Peters, R. D. and (1999) Quantifying tissue damage due to focused ultrasound heating observed by MRI. Magnetic Resonance in Medicine, 41, pp. 321 - 8.
    • (1999) Magnetic Resonance in Medicine , vol.41 , pp. 321-328
    • Graham, S.J.1    Chen, L.2    Leitch, M.3    Peters, R.D.4
  • 16
    • 0030996819 scopus 로고    scopus 로고
    • Thermal effects of focused ultrasound on the brain: Determination with MR imaging
    • Hynynen, K. and Vykhodtseva, N. I. and Chung, A. H. and Sorrentino, V. and (1997) Thermal effects of focused ultrasound on the brain: Determination with MR imaging. Radiology, 204, pp. 247 - 53.
    • (1997) Radiology , vol.204 , pp. 247-253
    • Hynynen, K.1    Vykhodtseva, N.I.2    Chung, A.H.3    Sorrentino, V.4
  • 17
  • 18
    • 32144456561 scopus 로고    scopus 로고
    • MR imaging detection of low-power focused ultrasound exposure of the brain
    • Hynynen, K. and Vykhodtseva, N. and Chung, A. and Colucci, V. and (1996) MR imaging detection of low-power focused ultrasound exposure of the brain. Radiology, 201, pp. 1252.
    • (1996) Radiology , vol.201 , pp. 1252
    • Hynynen, K.1    Vykhodtseva, N.2    Chung, A.3    Colucci, V.4
  • 19
    • 0029921684 scopus 로고    scopus 로고
    • Potential adverse effects of high-intensity focused ultrasound exposure on blood vessels in vivo
    • Hynynen, K. and Chung, A. H. and Colucci, V. and Jolesz, F. A. (1996) Potential adverse effects of high-intensity focused ultrasound exposure on blood vessels in vivo. Ultrasound in Medicine and Biology, 22, pp. 193 - 201.
    • (1996) Ultrasound in Medicine and Biology , vol.22 , pp. 193-201
    • Hynynen, K.1    Chung, A.H.2    Colucci, V.3    Jolesz, F.A.4
  • 20
    • 32144464195 scopus 로고
    • Noninvasive Blood-Vessel Occlusion with Mr Imaging-Guided Focused Ultrasound
    • Hynynen, K. and Colucci, V. and Chung, A. and Jolesz, F. A. (1995) Noninvasive Blood-Vessel Occlusion with Mr Imaging-Guided Focused Ultrasound. Radiology, 197, pp. 219.
    • (1995) Radiology , vol.197 , pp. 219
    • Hynynen, K.1    Colucci, V.2    Chung, A.3    Jolesz, F.A.4
  • 21
    • 0031886918 scopus 로고    scopus 로고
    • Calibration of water proton chemical shift with temperature for noninvasive temperature imaging during focused ultrasound surgery
    • Kuroda, K. and Chung, A. H. and Hynynen, K. and Jolesz, F. A. (1998) Calibration of water proton chemical shift with temperature for noninvasive temperature imaging during focused ultrasound surgery. Journal of Magnetic Resonance Imaging, 8, pp. 175 - 81.
    • (1998) Journal of Magnetic Resonance Imaging , vol.8 , pp. 175-181
    • Kuroda, K.1    Chung, A.H.2    Hynynen, K.3    Jolesz, F.A.4
  • 22
    • 0033905694 scopus 로고    scopus 로고
    • Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits
    • McDannold, N. J. and King, R. L. and Jolesz, F. A. and Hynynen, K. H. (2000) Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits. Radiology, 216, pp. 517 - 23.
    • (2000) Radiology , vol.216 , pp. 517-523
    • McDannold, N.J.1    King, R.L.2    Jolesz, F.A.3    Hynynen, K.H.4
  • 23
    • 0032974533 scopus 로고    scopus 로고
    • Real-time control of focused ultrasound heating based on rapid MR thermometry
    • Vimeux, F. C. and de Zwart, J. A. and Palussiere, J. and Fawaz, R. and (1999) Real-time control of focused ultrasound heating based on rapid MR thermometry. Investigative Radiology, 34, pp. 190 - 3.
    • (1999) Investigative Radiology , vol.34 , pp. 190-193
    • Vimeux, F.C.1    de Zwart, J.A.2    Palussiere, J.3    Fawaz, R.4
  • 25
    • 0035035077 scopus 로고    scopus 로고
    • Laser-induced interstitial thermotherapy of liver metastases in an interventional 0.5 tesla MRI system: Technique and first clinical experiences
    • Fiedler, V. U. and Schwarzmaier, H. J. and Eickmeyer, F. and Muller, F. P. and (2001) Laser-induced interstitial thermotherapy of liver metastases in an interventional 0.5 tesla MRI system: Technique and first clinical experiences. Journal of Magnetic Resonance Imaging, 13, pp. 729 - 37.
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , pp. 729-737
    • Fiedler, V.U.1    Schwarzmaier, H.J.2    Eickmeyer, F.3    Muller, F.P.4
  • 26
    • 0032209309 scopus 로고    scopus 로고
    • Laser-induced thermotherapy for the treatment of liver metastasis - Correlation of gadolinium-DTPA-enhanced MRI with histomorphologic findings to determine criteria for follow-up monitoring
    • Germer, C. T. and Isbert, C. M. and Albrecht, D. and Ritz, J. P. and (1998) Laser-induced thermotherapy for the treatment of liver metastasis - Correlation of gadolinium-DTPA-enhanced MRI with histomorphologic findings to determine criteria for follow-up monitoring. Surgical Endoscopy and Other Interventional Techniques, 12, pp. 1317 - 25.
    • (1998) Surgical Endoscopy and Other Interventional Techniques , vol.12 , pp. 1317-1325
    • Germer, C.T.1    Isbert, C.M.2    Albrecht, D.3    Ritz, J.P.4
  • 27
    • 19944430897 scopus 로고    scopus 로고
    • Image guided interstitial laser thermotherapy: A canine model evaluated by magnetic resonance imaging and quantitative autoradiography
    • Muacevic, A. and Peller, M. and Ruprecht, L. and Berg, D. and (2005) Image guided interstitial laser thermotherapy: A canine model evaluated by magnetic resonance imaging and quantitative autoradiography. Acta Neurochirurgica, 147, pp. 175 - 86.
    • (2005) Acta Neurochirurgica , vol.147 , pp. 175-186
    • Muacevic, A.1    Peller, M.2    Ruprecht, L.3    Berg, D.4
  • 28
    • 0033661583 scopus 로고    scopus 로고
    • Magnetic resonance thermometry for predicting thermal damage: An application of interstitial laser coagulation in an in vivo canine prostate model
    • Peters, R. D. and Chan, E. and Trachtenberg, J. and Jothy, S. and (2000) Magnetic resonance thermometry for predicting thermal damage: An application of interstitial laser coagulation in an in vivo canine prostate model. Magnetic Resonance in Medicine, 44, pp. 873 - 83.
    • (2000) Magnetic Resonance in Medicine , vol.44 , pp. 873-883
    • Peters, R.D.1    Chan, E.2    Trachtenberg, J.3    Jothy, S.4
  • 29
    • 0041590978 scopus 로고    scopus 로고
    • Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation
    • Weidensteiner, C. and Quesson, B. and Caire-Gana, B. and Kerioui, N. and (2003) Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation. Magnetic Resonance in Medicine, 50, pp. 322 - 30.
    • (2003) Magnetic Resonance in Medicine , vol.50 , pp. 322-330
    • Weidensteiner, C.1    Quesson, B.2    Caire-Gana, B.3    Kerioui, N.4
  • 30
    • 0035041810 scopus 로고    scopus 로고
    • Radiofrequency tissue ablation: Physical principles and techniques for increasing coagulation necrosis
    • Goldberg, S. N. and Gazelle, G. S. (2001) Radiofrequency tissue ablation: Physical principles and techniques for increasing coagulation necrosis. Hepatogastroenterology, 48, pp. 359 - 67.
    • (2001) Hepatogastroenterology , vol.48 , pp. 359-367
    • Goldberg, S.N.1    Gazelle, G.S.2
  • 31
    • 0032013103 scopus 로고    scopus 로고
    • History of cryosurgery
    • Gage, A. A. (1998) History of cryosurgery. Semin Surg Oncol, 14, pp. 99 - 109.
    • (1998) Semin Surg Oncol , vol.14 , pp. 99-109
    • Gage, A.A.1
  • 32
    • 0032209678 scopus 로고    scopus 로고
    • Mechanisms of tissue injury in cryosurgery
    • Gage, A. A. and Baust, J. (1998) Mechanisms of tissue injury in cryosurgery. Cryobiology, 37, pp. 171 - 86.
    • (1998) Cryobiology , vol.37 , pp. 171-186
    • Gage, A.A.1    Baust, J.2
  • 33
    • 0028785052 scopus 로고
    • A precise and fast temperature mapping using water proton chemical shift
    • Ishihara, Y. and Calderon, A. and Watanabe, H. and Okamoto, K. and (1995) A precise and fast temperature mapping using water proton chemical shift. Magnetic Resonance in Medicine, 34, pp. 814 - 23.
    • (1995) Magnetic Resonance in Medicine , vol.34 , pp. 814-823
    • Ishihara, Y.1    Calderon, A.2    Watanabe, H.3    Okamoto, K.4
  • 34
    • 0031848730 scopus 로고    scopus 로고
    • Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry
    • Peters, R. D. and Hinks, R. S. and Henkelman, R. M. (1998) Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magnetic Resonance in Medicine, 40, pp. 454 - 9.
    • (1998) Magnetic Resonance in Medicine , vol.40 , pp. 454-459
    • Peters, R.D.1    Hinks, R.S.2    Henkelman, R.M.3
  • 36
    • 0032769191 scopus 로고    scopus 로고
    • Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation
    • de Zwart, J. A. and Vimeux, F. C. and Delalande, C. and Canioni, P. and (1999) Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation. Magnetic Resonance in Medicine, 42, pp. 53 - 9.
    • (1999) Magnetic Resonance in Medicine , vol.42 , pp. 53-59
    • de Zwart, J.A.1    Vimeux, F.C.2    Delalande, C.3    Canioni, P.4
  • 37
    • 0347634470 scopus 로고    scopus 로고
    • On the calculation and interpretation of signal intensity in echo-shifted sequences
    • Denolin, V. and Metens, T. (2004) On the calculation and interpretation of signal intensity in echo-shifted sequences. Magnetic Resonance in Medicine, 51, pp. 123 - 34.
    • (2004) Magnetic Resonance in Medicine , vol.51 , pp. 123-134
    • Denolin, V.1    Metens, T.2
  • 40
    • 0242290981 scopus 로고    scopus 로고
    • Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion
    • Vigen, K. K. and Daniel, B. L. and Pauly, J. M. and Butts, K. (2003) Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion. Magnetic Resonance in Medicine, 50, pp. 1003 - 10.
    • (2003) Magnetic Resonance in Medicine , vol.50 , pp. 1003-1010
    • Vigen, K.K.1    Daniel, B.L.2    Pauly, J.M.3    Butts, K.4
  • 42
    • 0022730617 scopus 로고
    • Ultrasound monitored hepatic cryosurgery: Longevity study on an animal model
    • Gilbert, J. C. and Onik, G. M. and Hoddick, W. K. and Rubinsky, B. and (1986) Ultrasound monitored hepatic cryosurgery: Longevity study on an animal model. Cryobiology, 23, pp. 277 - 85.
    • (1986) Cryobiology , vol.23 , pp. 277-285
    • Gilbert, J.C.1    Onik, G.M.2    Hoddick, W.K.3    Rubinsky, B.4
  • 43
    • 0030713453 scopus 로고    scopus 로고
    • The interventional magnetic resonance unit--the minimal access operating theatre of the future?
    • Spec No
    • Gould, S. W. and Darzi, A. (1997) The interventional magnetic resonance unit--the minimal access operating theatre of the future? Br J Radiol, 70 Spec No, pp. S89 - S97.
    • (1997) Br J Radiol , vol.70
    • Gould, S.W.1    Darzi, A.2
  • 44
    • 0033001064 scopus 로고    scopus 로고
    • Magnetic resonance imaging of frozen tissues: Temperature-dependent MR signal characteristics and relevance for MR monitoring of cryosurgery
    • Daniel, B. L. and Butts, K. and Block, W. F. (1999) Magnetic resonance imaging of frozen tissues: Temperature-dependent MR signal characteristics and relevance for MR monitoring of cryosurgery. Magn Reson Med, 41, pp. 627 - 30.
    • (1999) Magn Reson Med , vol.41 , pp. 627-630
    • Daniel, B.L.1    Butts, K.2    Block, W.F.3
  • 45
    • 0027937312 scopus 로고
    • MR imaging assisted temperature calculations during cryosurgery
    • Hong, J. S. and Wong, S. and Pease, G. and Rubinsky, B. (1994) MR imaging assisted temperature calculations during cryosurgery. Magnetic Resonance Imaging, 12, pp. 1021 - 31.
    • (1994) Magnetic Resonance Imaging , vol.12 , pp. 1021-1031
    • Hong, J.S.1    Wong, S.2    Pease, G.3    Rubinsky, B.4
  • 46
    • 0030825654 scopus 로고    scopus 로고
    • Temperature determination in the frozen region during cryosurgery of rabbit liver using MR image analysis
    • Gilbert, J. C. and Rubinsky, B. and Wong, S. T. and Brennan, K. M. and (1997) Temperature determination in the frozen region during cryosurgery of rabbit liver using MR image analysis. Magn Reson Imaging, 15, pp. 657 - 67.
    • (1997) Magn Reson Imaging , vol.15 , pp. 657-667
    • Gilbert, J.C.1    Rubinsky, B.2    Wong, S.T.3    Brennan, K.M.4
  • 47
    • 0032771607 scopus 로고    scopus 로고
    • Imaging of interstitial cryotherapy--an in vitro comparison of ultrasound, computed tomography, and magnetic resonance imaging
    • Tacke, J. and Speetzen, R. and Heschel, I. and Hunter, D. W. and (1999) Imaging of interstitial cryotherapy--an in vitro comparison of ultrasound, computed tomography, and magnetic resonance imaging. Cryobiology, 38, pp. 250 - 9.
    • (1999) Cryobiology , vol.38 , pp. 250-259
    • Tacke, J.1    Speetzen, R.2    Heschel, I.3    Hunter, D.W.4
  • 49
    • 0021981854 scopus 로고
    • Effect of varying freezing and thawing rates in experimental cryosurgery
    • Gage, A. A. and Guest, K. and Montes, M. and Caruana, J. A. and (1985) Effect of varying freezing and thawing rates in experimental cryosurgery. Cryobiology, 22, pp. 175 - 82.
    • (1985) Cryobiology , vol.22 , pp. 175-182
    • Gage, A.A.1    Guest, K.2    Montes, M.3    Caruana, J.A.4
  • 50
    • 0034885419 scopus 로고    scopus 로고
    • Validation of estimated 3D temperature maps during hepatic cryo surgery
    • Samset, E. and Mala, T. and Edwin, B. and Gladhaug, I. and (2001) Validation of estimated 3D temperature maps during hepatic cryo surgery. Magnetic Resonance Imaging, 19, pp. 715 - 21.
    • (2001) Magnetic Resonance Imaging , vol.19 , pp. 715-721
    • Samset, E.1    Mala, T.2    Edwin, B.3    Gladhaug, I.4
  • 51
    • 0034838736 scopus 로고    scopus 로고
    • Temperature measurement in soft tissue using a distributed fibre Bragg-grating sensor system
    • Samset, E. and Mala, T. and Ellingsen, R. and Gladhaug, I. and (2000) Temperature measurement in soft tissue using a distributed fibre Bragg-grating sensor system. Min Invas Ther & Allied Technol, 10, pp. 89 - 93.
    • (2000) Min Invas Ther & Allied Technol , vol.10 , pp. 89-93
    • Samset, E.1    Mala, T.2    Ellingsen, R.3    Gladhaug, I.4
  • 52
    • 0036201585 scopus 로고    scopus 로고
    • Magnetic resonance imaging-estimated three-dimensional temperature distribution in liver cryolesions: A study of cryolesion characteristics assumed necessary for tumor ablation
    • Mala, T. and Samset, E. and Aurdal, L. and Gladhaug, I. and (2001) Magnetic resonance imaging-estimated three-dimensional temperature distribution in liver cryolesions: A study of cryolesion characteristics assumed necessary for tumor ablation. Cryobiology, 43, pp. 268 - 75.
    • (2001) Cryobiology , vol.43 , pp. 268-275
    • Mala, T.1    Samset, E.2    Aurdal, L.3    Gladhaug, I.4
  • 53
    • 0034762213 scopus 로고    scopus 로고
    • Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses
    • Wansapura, J. P. and Daniel, B. L. and Pauly, J. and Butts, K. (2001) Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses. Magnetic Resonance in Medicine, 46, pp. 985 - 92.
    • (2001) Magnetic Resonance in Medicine , vol.46 , pp. 985-992
    • Wansapura, J.P.1    Daniel, B.L.2    Pauly, J.3    Butts, K.4
  • 54
    • 0033962907 scopus 로고    scopus 로고
    • Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue
    • Peters, R. D. and Henkelman, R. M. (2000) Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue. Magnetic Resonance in Medicine, 43, pp. 62 - 71.
    • (2000) Magnetic Resonance in Medicine , vol.43 , pp. 62-71
    • Peters, R.D.1    Henkelman, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.