Volumn 3, Issue , 2004, Pages 1262-1266

Understanding ferroresonance

Author keywords

ATP EMTP; Circuit Breaker Grading Capacitors; Ferroresonance; Inductive Voltage Transformers; Non Linear Dynamics; Power System Modelling

Indexed keywords

CAPACITORS; COMPUTER SIMULATION; DYNAMICS; ELECTRIC CIRCUIT BREAKERS; ELECTRIC POTENTIAL; ELECTRIC POWER SYSTEMS; ELECTRIC SUBSTATIONS; ELECTRIC TRANSFORMERS;

EID: 32044464551     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (13)

References (12)
  • 1
    • 0010116797 scopus 로고
    • Existence de deux régimes en ferrorésonance
    • Dec. 10
    • Boucherot, "Existence de deux régimes en ferrorésonance," R.G.E., pp. 827-828, Dec. 10, 1920.
    • (1920) R.G.E. , pp. 827-828
    • Boucherot1
  • 2
    • 0033724008 scopus 로고    scopus 로고
    • Modelling and analysis guidelines for slow transients - Part III: The study of ferroresonance
    • January
    • Slow Transients Task Force of the IEEE Working Group on Modelling and Analysis of System Transients Using Digital Programs. Modelling and Analysis Guidelines for Slow Transients - Part III: The Study of Ferroresonance, IEEE Trans. on Power Delivery. Vol 15, No 1. January 2000.
    • (2000) IEEE Trans. on Power Delivery , vol.15 , Issue.1
  • 3
    • 0038155297 scopus 로고    scopus 로고
    • A systematical method for suppressing ferroresonance at neutral-grounded substations
    • July
    • Yunge Li, Wei Shi, Rui Qin and Jilin Yang: A Systematical Method for Suppressing Ferroresonance at Neutral-Grounded Substations, IEEE Trans. on Power Delivery, Vol. 18, No 3, pp 1009-1014, July 2003.
    • (2003) IEEE Trans. on Power Delivery , vol.18 , Issue.3 , pp. 1009-1014
    • Li, Y.1    Shi, W.2    Qin, R.3    Yang, J.4
  • 7
    • 0024038390 scopus 로고
    • Large mill power outages caused by potential transformer ferroresonance
    • July/August
    • D. Ray Crane, G. W. Walsh: Large Mill Power Outages caused by Potential Transformer Ferroresonance, IEEE Trans. on Industry Applications, Vol 24, No 4, pp 635-640, July/August 1988.
    • (1988) IEEE Trans. on Industry Applications , vol.24 , Issue.4 , pp. 635-640
    • Ray Crane, D.1    Walsh, G.W.2
  • 9
    • 47149089555 scopus 로고    scopus 로고
    • Elimination of temporary overvoltages due to ferroresonance of voltage transformers: Design and testing of a damping system
    • CIGRE paper 33204
    • N. Janssens, V. Vanderstockt, H. Denoel, P. A. Monflis: Elimination of Temporary Overvoltages due to Ferroresonance of Voltage Transformers: Design and Testing of a Damping System. CIGRE paper 33-204. Procs. of the CIGRE 1990 session.
    • Procs. of the CIGRE 1990 Session
    • Janssens, N.1    Vanderstockt, V.2    Denoel, H.3    Monflis, P.A.4
  • 10
    • 84916820201 scopus 로고    scopus 로고
    • Protection of EHV power systems against ferroresonance
    • Procs. of the CIGRE 1990 session
    • P. Bernard, V. Collet Billon, C. Kieny: Protection of EHV Power Systems against Ferroresonance, Procs. CIGRE paper 34-103. Procs. of the CIGRE 1990 session.
    • Procs. CIGRE Paper , vol.34 , Issue.103
    • Bernard, P.1    Billon, V.C.2    Kieny, C.3
  • 11
    • 47149084104 scopus 로고    scopus 로고
    • Investigation of station service transformer ferroresonance in manitoba Hydro's 230-kV dorsey converter station
    • Rio de Janeiro, June 24-28
    • D. A. N. Jacobson, R. W. Menzies: Investigation of Station Service Transformer Ferroresonance in Manitoba Hydro's 230-kV Dorsey Converter Station, Procs. of the 4-th International Conference on Power System Transients, Rio de Janeiro, June 24-28, 2001.
    • (2001) Procs. of the 4-th International Conference on Power System Transients
    • Jacobson, D.A.N.1    Menzies, R.W.2