-
1
-
-
0028891962
-
The use of titanium in dentistry
-
T. Okabe, and H. Hero The use of titanium in dentistry Cells Mater 5 1995 211 230
-
(1995)
Cells Mater
, vol.5
, pp. 211-230
-
-
Okabe, T.1
Hero, H.2
-
2
-
-
0030310863
-
Titanium in dentistry: Development and research in the U.S.A
-
H. Nakajima, and T. Okabe Titanium in dentistry: Development and research in the U.S.A Dent Mater J 15 1996 77 90
-
(1996)
Dent Mater J
, vol.15
, pp. 77-90
-
-
Nakajima, H.1
Okabe, T.2
-
3
-
-
0024031409
-
Clinical application of pure titanium for cast plate dentures
-
M. Yamauchi, M. Sakai, and J. Kawano Clinical application of pure titanium for cast plate dentures Dent Mater 7 1988 39 47
-
(1988)
Dent Mater
, vol.7
, pp. 39-47
-
-
Yamauchi, M.1
Sakai, M.2
Kawano, J.3
-
4
-
-
0025287393
-
A 2-year follow-up study of titanium crowns
-
B. Bergman, C. Bessing, G. Ericson, P. Lundquist, H. Nilson, and M. Andersson A 2-year follow-up study of titanium crowns Acta Odontol Scand 48 1990 113 117
-
(1990)
Acta Odontol Scand
, vol.48
, pp. 113-117
-
-
Bergman, B.1
Bessing, C.2
Ericson, G.3
Lundquist, P.4
Nilson, H.5
Andersson, M.6
-
5
-
-
0029178725
-
Titanium framework removable partial denture used for patients allergic to other metals: A clinical report and literature review
-
M. Kononen, J. Rintanen, A. Waltimo, and P. Kempainen Titanium framework removable partial denture used for patients allergic to other metals: a clinical report and literature review J Prosthet Dent 73 1995 4 7
-
(1995)
J Prosthet Dent
, vol.73
, pp. 4-7
-
-
Kononen, M.1
Rintanen, J.2
Waltimo, A.3
Kempainen, P.4
-
6
-
-
0029375103
-
Stereo laser-welded titanium implant frameworks: Clinical and laboratory procedures with a summary of 1-year clinical trials
-
J.E. Rubenstein Stereo laser-welded titanium implant frameworks: clinical and laboratory procedures with a summary of 1-year clinical trials J Prosthet Dent 74 1995 284 293
-
(1995)
J Prosthet Dent
, vol.74
, pp. 284-293
-
-
Rubenstein, J.E.1
-
7
-
-
0007771959
-
Quantitative evaluation of porosities in pure titanium castings
-
T. Aoki Quantitative evaluation of porosities in pure titanium castings Tsurumi Univ Dent J 22 1996 15 31
-
(1996)
Tsurumi Univ Dent J
, vol.22
, pp. 15-31
-
-
Aoki, T.1
-
8
-
-
0024305598
-
High temperature reactivity between titanium and refractory oxides in dental casting procedure
-
F. Watari High temperature reactivity between titanium and refractory oxides in dental casting procedure J Jpn Dent Mater 8 1989 83 96
-
(1989)
J Jpn Dent Mater
, vol.8
, pp. 83-96
-
-
Watari, F.1
-
9
-
-
0024345249
-
Studies of Ti alloys for dental castings
-
M. Taira, J.B. Moser, and E.H. Greener Studies of Ti alloys for dental castings Dent Mater 5 1989 45 50
-
(1989)
Dent Mater
, vol.5
, pp. 45-50
-
-
Taira, M.1
Moser, J.B.2
Greener, E.H.3
-
10
-
-
0029311645
-
Porosity and accuracy of multiple-unit titanium castings
-
T.I. Chai, and R.S. Stein Porosity and accuracy of multiple-unit titanium castings J Prosthet Dent 73 1995 534 540
-
(1995)
J Prosthet Dent
, vol.73
, pp. 534-540
-
-
Chai, T.I.1
Stein, R.S.2
-
11
-
-
0031086268
-
Effect of pressure difference on the quality of titanium casting
-
I. Watanabe, J.H. Watkins, H. Nakajima, M. Atsuta, and T. Okabe Effect of pressure difference on the quality of titanium casting J Dent Res 76 1997 773 779
-
(1997)
J Dent Res
, vol.76
, pp. 773-779
-
-
Watanabe, I.1
Watkins, J.H.2
Nakajima, H.3
Atsuta, M.4
Okabe, T.5
-
12
-
-
0342673371
-
An examination of polishing steps for titanium castings
-
Y. Kawai, Y. Takayama, M. Abe, A. Ohshima, T. Hosoi, and K. Sugiyama An examination of polishing steps for titanium castings Tsurumi Dent J 23 1997 407 415
-
(1997)
Tsurumi Dent J
, vol.23
, pp. 407-415
-
-
Kawai, Y.1
Takayama, Y.2
Abe, M.3
Ohshima, A.4
Hosoi, T.5
Sugiyama, K.6
-
13
-
-
0033630297
-
Shear bond strengths of polymethyl methacrylate to cast titanium and cobalt-chromium frameworks using five metal primers
-
C. Ohkubo, I. Watanabe, T. Hosoi, and T. Okabe Shear bond strengths of polymethyl methacrylate to cast titanium and cobalt-chromium frameworks using five metal primers J Prosthet Dent 83 1 2000 50 57
-
(2000)
J Prosthet Dent
, vol.83
, Issue.1
, pp. 50-57
-
-
Ohkubo, C.1
Watanabe, I.2
Hosoi, T.3
Okabe, T.4
-
14
-
-
0036885764
-
In vitro wear assessment of titanium alloy teeth
-
C. Ohkubo, I. Shimura, T. Aoki, S. Hanatani, T. Hosoi, and T. Okabe In vitro wear assessment of titanium alloy teeth J Prosthod 11 4 2002 263 269
-
(2002)
J Prosthod
, vol.11
, Issue.4
, pp. 263-269
-
-
Ohkubo, C.1
Shimura, I.2
Aoki, T.3
Hanatani, S.4
Hosoi, T.5
Okabe, T.6
-
15
-
-
0037708481
-
Wear resistance of experimental Ti-Cu alloys
-
C. Ohkubo, I. Shimura, T. Aoki, S. Hanatani, T. Hosoi, and M. Hattori Wear resistance of experimental Ti-Cu alloys Biomaterials 24 2003 3377 3381
-
(2003)
Biomaterials
, vol.24
, pp. 3377-3381
-
-
Ohkubo, C.1
Shimura, I.2
Aoki, T.3
Hanatani, S.4
Hosoi, T.5
Hattori, M.6
-
16
-
-
0011697179
-
Polishing of titanium prosthetics (Part 1). Mechanical polishing by dental laboratory rotary wheels
-
T. Miyazaki, Y. Tamaki, E. Suzuki, and T. Miyaji Polishing of titanium prosthetics (Part 1). Mechanical polishing by dental laboratory rotary wheels J Jpn Dent Mater 6 1987 917 922
-
(1987)
J Jpn Dent Mater
, vol.6
, pp. 917-922
-
-
Miyazaki, T.1
Tamaki, Y.2
Suzuki, E.3
Miyaji, T.4
-
17
-
-
0024982303
-
Grinding of titanium, Part 1. Commercial and experimental wheels made of silicon carbide abrasives
-
O. Miyakawa, K. Watanabe, S. Okawa, S. Nakano, N. Shiokawa, M. Kobayashi, and H. Tamura Grinding of titanium, Part 1. Commercial and experimental wheels made of silicon carbide abrasives J Jpn Dent Mater 9 1990 30 41
-
(1990)
J Jpn Dent Mater
, vol.9
, pp. 30-41
-
-
Miyakawa, O.1
Watanabe, K.2
Okawa, S.3
Nakano, S.4
Shiokawa, N.5
Kobayashi, M.6
Tamura, H.7
-
18
-
-
0024982161
-
Grinding of titanium. Part 2. Commercial vitrified wheels made of alumina abrasives
-
O. Miyakawa, K. Watanabe, S. Okawa, S. Nakano, N. Shiokawa, and M. Kobayashi Grinding of titanium. Part 2. Commercial vitrified wheels made of alumina abrasives J Jpn Dent Mater 9 1990 42 52
-
(1990)
J Jpn Dent Mater
, vol.9
, pp. 42-52
-
-
Miyakawa, O.1
Watanabe, K.2
Okawa, S.3
Nakano, S.4
Shiokawa, N.5
Kobayashi, M.6
-
20
-
-
0033985882
-
The machinability of cast titanium and Ti-6Al-4V
-
C. Ohkubo, I. Watanabe, J.P. Ford, H. Nakajima, T. Hosoi, and T. Okabe The machinability of cast titanium and Ti-6Al-4V Biomaterials 21 2000 421 428
-
(2000)
Biomaterials
, vol.21
, pp. 421-428
-
-
Ohkubo, C.1
Watanabe, I.2
Ford, J.P.3
Nakajima, H.4
Hosoi, T.5
Okabe, T.6
-
21
-
-
0034328485
-
Cutting efficiency of air-turbine burs on cast titanium and dental casting alloys
-
I. Watanabe, C. Ohkubo, M. Atsuta, and T. Okabe Cutting efficiency of air-turbine burs on cast titanium and dental casting alloys Dent Mater 16 6 2000 420 425
-
(2000)
Dent Mater
, vol.16
, Issue.6
, pp. 420-425
-
-
Watanabe, I.1
Ohkubo, C.2
Atsuta, M.3
Okabe, T.4
-
22
-
-
1842869161
-
Machinability of cast commercial titanium alloys
-
I. Watanabe, S. Kiyosue, C. Ohkubo, T. Aoki, and T. Okabe Machinability of cast commercial titanium alloys J Biomed Mater Res 63 2002 760 764
-
(2002)
J Biomed Mater Res
, vol.63
, pp. 760-764
-
-
Watanabe, I.1
Kiyosue, S.2
Ohkubo, C.3
Aoki, T.4
Okabe, T.5
-
23
-
-
0041491427
-
Grindability of cast Ti-Cu alloys
-
M. Kikuchi, Y. Takada, S. Kiyosue, M. Yoda, M. Woldu, and Z. Cai Grindability of cast Ti-Cu alloys Dent Mater 19 2003 375 381
-
(2003)
Dent Mater
, vol.19
, pp. 375-381
-
-
Kikuchi, M.1
Takada, Y.2
Kiyosue, S.3
Yoda, M.4
Woldu, M.5
Cai, Z.6
-
24
-
-
0003802209
-
-
Metals Park, OH: American Society for Metals
-
Metals handbook desk edition. Metals Park, OH: American Society for Metals; 1984. p. 1-24.
-
(1984)
Metals Handbook Desk Edition
, pp. 1-24
-
-
-
27
-
-
0011577324
-
Study on the dental application of machinable titanium alloys: Machinability of ingots
-
M. Taira, S. Ogino, K. Wakasa, and Y. Yamaki Study on the dental application of machinable titanium alloys: machinability of ingots J Jpn Dent Mater 13 1994 128 129
-
(1994)
J Jpn Dent Mater
, vol.13
, pp. 128-129
-
-
Taira, M.1
Ogino, S.2
Wakasa, K.3
Yamaki, Y.4
|