메뉴 건너뛰기




Volumn 31, Issue 6, 2005, Pages 268-269

Therapeutic applications of lotrafilcon A silicone hydrogel soft contact lenses

Author keywords

Corneal disease; Silicone hydrogel contact lens; Therapeutic contact lens

Indexed keywords

ANTIBIOTIC AGENT; ANTIGLAUCOMA AGENT; COPOLYMER; LOTRAFILCON A; NONSTEROID ANTIINFLAMMATORY AGENT; SILICONE; STEROID; UNCLASSIFIED DRUG;

EID: 31944432559     PISSN: 15422321     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ICL.0000163449.92288.71     Document Type: Article
Times cited : (18)

References (8)
  • 1
    • 0038340374 scopus 로고    scopus 로고
    • Retrospective case series of therapeutic applications of a lotrafilcon a silicone hydrogel soft contact lens
    • Montero J, Sparholt J, Mely R. Retrospective case series of therapeutic applications of a lotrafilcon A silicone hydrogel soft contact lens. Eye Contact Lens 2003;29:54-56.
    • (2003) Eye Contact Lens , vol.29 , pp. 54-56
    • Montero, J.1    Sparholt, J.2    Mely, R.3
  • 3
    • 31944448917 scopus 로고    scopus 로고
    • Extended wear
    • Bennett ES, Henry VA, eds. Philadelphia, Lippincott Williams & Wilkins
    • Bennett E, Purcell H, Biddle SP. Extended wear. In: Bennett ES, Henry VA, eds. Clinical Manual of Contact Lenses. Philadelphia, Lippincott Williams & Wilkins, 2000, pp 450-457.
    • (2000) Clinical Manual of Contact Lenses , pp. 450-457
    • Bennett, E.1    Purcell, H.2    Biddle, S.P.3
  • 4
    • 2042475628 scopus 로고    scopus 로고
    • Dk performance of lotrafilcon A following thirty night extended wear
    • Winterton L, Morgan CF, Long B, et al. Dk performance of lotrafilcon A following thirty night extended wear. Optometry in Practice 2000;1:37-42.
    • (2000) Optometry in Practice , vol.1 , pp. 37-42
    • Winterton, L.1    Morgan, C.F.2    Long, B.3
  • 5
    • 0030955386 scopus 로고    scopus 로고
    • High-oxygen-transmissibility soft contact lenses do not induce limbal hyperaemia
    • Papas E, Vajdic C, Austen R, et al. High-oxygen-transmissibility soft contact lenses do not induce limbal hyperaemia. Curr Eye Res 1997;16:942-948.
    • (1997) Curr Eye Res , vol.16 , pp. 942-948
    • Papas, E.1    Vajdic, C.2    Austen, R.3
  • 6
    • 0001125775 scopus 로고    scopus 로고
    • A comparison of the vascular response to extended wear of conventional lower Dk and experimental high Dk hydrogel contact lenses
    • Dumbleton K, Richter D, Simpson T, et al. A comparison of the vascular response to extended wear of conventional lower Dk and experimental high Dk hydrogel contact lenses. Optom Vis Sci 1998;75:170.
    • (1998) Optom Vis Sci , vol.75 , pp. 170
    • Dumbleton, K.1    Richter, D.2    Simpson, T.3
  • 7
    • 0032742403 scopus 로고    scopus 로고
    • Sympathetic swelling response of the control eye to soft lenses in the other eye
    • Fonn D, du Toit R, Simpson T, et al. Sympathetic swelling response of the control eye to soft lenses in the other eye. Invest Ophthalmol Vis Sci 1999;40:3116-3121.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , pp. 3116-3121
    • Fonn, D.1    Du Toit, R.2    Simpson, T.3
  • 8
    • 0016724036 scopus 로고
    • The use of soft bandage lenses in corneal disease
    • Amos D. The use of soft bandage lenses in corneal disease. Am J Optom Physiol Opt 1975;52:524-533.
    • (1975) Am J Optom Physiol Opt , vol.52 , pp. 524-533
    • Amos, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.