메뉴 건너뛰기




Volumn 20, Issue 1, 2006, Pages 129-131

Silbronco double-lumen tube [5]

Author keywords

[No Author keywords available]

Indexed keywords

POLYVINYLCHLORIDE; SILICONE;

EID: 31844446072     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.jvca.2005.03.035     Document Type: Letter
Times cited : (18)

References (11)
  • 1
    • 0000163846 scopus 로고
    • The prevention of spread during pulmonary resection by the use of a double-lumen catheter
    • V.O. Bjork, E. Carlens The prevention of spread during pulmonary resection by the use of a double-lumen catheter J Thorac Surg 20 1950 151 157
    • (1950) J Thorac Surg , vol.20 , pp. 151-157
    • Bjork, V.O.1    Carlens, E.2
  • 2
    • 0008331160 scopus 로고
    • A double-lumen endobronchial tube
    • R. Bryce-Smith A double-lumen endobronchial tube Br J Anaesth 31 1959 274 275
    • (1959) Br J Anaesth , vol.31 , pp. 274-275
    • Bryce-Smith, R.1
  • 3
    • 0008331162 scopus 로고
    • A new double lumen tube
    • G.M. White A new double lumen tube Br J Anaesth 32 1960 232 234
    • (1960) Br J Anaesth , vol.32 , pp. 232-234
    • White, G.M.1
  • 4
    • 0000091955 scopus 로고
    • Low resistance double-lumen endobronchial tubes
    • F.L. Robertshaw Low resistance double-lumen endobronchial tubes Br J Anaesth 34 1962 576 579
    • (1962) Br J Anaesth , vol.34 , pp. 576-579
    • Robertshaw, F.L.1
  • 5
    • 0020534642 scopus 로고
    • Advantages of a polyvinyl chloride double-lumen tube over conventional double-lumen tubes in thoracic surgery
    • N.A. Burton, D.C. Watson, J.B. Brodsky Advantages of a polyvinyl chloride double-lumen tube over conventional double-lumen tubes in thoracic surgery Ann Thorac Surg 36 1983 78 84
    • (1983) Ann Thorac Surg , vol.36 , pp. 78-84
    • Burton, N.A.1    Watson, D.C.2    Brodsky, J.B.3
  • 6
    • 0034767193 scopus 로고    scopus 로고
    • New landmarks improve the positioning of the left Broncho-Cath double-lumen tube: Comparison with the classic technique
    • G. Fortier, D. Cote, C. Bergeron New landmarks improve the positioning of the left Broncho-Cath double-lumen tube Comparison with the classic technique Can J Anaesth 48 2001 790 794
    • (2001) Can J Anaesth , vol.48 , pp. 790-794
    • Fortier, G.1    Cote, D.2    Bergeron, C.3
  • 7
    • 0024998832 scopus 로고
    • Double-lumen tube design fault
    • F.M. Desai, D.A. Rocke Double-lumen tube design fault Anesthesiology 73 1990 575 576
    • (1990) Anesthesiology , vol.73 , pp. 575-576
    • Desai, F.M.1    Rocke, D.A.2
  • 8
    • 85088327402 scopus 로고
    • Improvement of the left Broncho-Cath double-lumen tube
    • N. Yahagi, H. Furuya, J. Matsui Improvement of the left Broncho-Cath double-lumen tube Anesthesiology 81 1994 781 782
    • (1994) Anesthesiology , vol.81 , pp. 781-782
    • Yahagi, N.1    Furuya, H.2    Matsui, J.3
  • 9
    • 0037325987 scopus 로고    scopus 로고
    • Dimensions of double-lumen tracheobronchial tubes
    • W.J. Russell, T.S. Strong Dimensions of double-lumen tracheobronchial tubes Anaesth Intens Care 31 2003 50 53
    • (2003) Anaesth Intens Care , vol.31 , pp. 50-53
    • Russell, W.J.1    Strong, T.S.2
  • 10
    • 0023449789 scopus 로고
    • Margin of safety in positioning modern double-lumen endotracheal tubes
    • J.L. Benumof, B.L. Partridge, C. Salvatierra Margin of safety in positioning modern double-lumen endotracheal tubes Anesthesiology 67 1987 729 738
    • (1987) Anesthesiology , vol.67 , pp. 729-738
    • Benumof, J.L.1    Partridge, B.L.2    Salvatierra, C.3
  • 11
    • 0029998807 scopus 로고    scopus 로고
    • Tracheal diameter predicts double-lumen tube size: A method for selecting left double lumen tubes
    • J.B. Brodsky, A. Macario, J.B.D. Mark Tracheal diameter predicts double-lumen tube size A method for selecting left double lumen tubes Anesth Analg 82 1996 861 864
    • (1996) Anesth Analg , vol.82 , pp. 861-864
    • Brodsky, J.B.1    MacArio, A.2    Mark, J.B.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.