메뉴 건너뛰기




Volumn 113, Issue 2, 2006, Pages 639-648

Characterization of microtiterplates with integrated optical sensors for oxygen and pH, and their applications to enzyme activity screening, respirometry, and toxicological assays

Author keywords

Enzyme activity; MTP; Optical oxygen sensor; Optical pH sensor; Respiratory activity

Indexed keywords

ENZYME ACTIVITY; MICROTITERPLATES (MTP); OPTICAL OXYGEN SENSORS; OPTICAL PH SENSORS; RESPIRATORY ACTIVITY;

EID: 31844445411     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2005.07.056     Document Type: Article
Times cited : (63)

References (15)
  • 1
    • 1542648923 scopus 로고    scopus 로고
    • Fluorescence-based cell viability screening assays using water-soluble oxygen probes
    • J. Hynes, S. Floyd, A.E. Soini, R. O'Connor, and D.B. Papkovsky Fluorescence-based cell viability screening assays using water-soluble oxygen probes J. Biomol. Screen 8 2003 264 272
    • (2003) J. Biomol. Screen , vol.8 , pp. 264-272
    • Hynes, J.1    Floyd, S.2    Soini, A.E.3    O'Connor, R.4    Papkovsky, D.B.5
  • 2
    • 1842610151 scopus 로고    scopus 로고
    • A low-volume platform for cell-respirometric screening based on quenched-luminescence oxygen sensing
    • J. Alderman, J. Hynes, S.M. Floyd, J. Kruger, R. O'Connor, and D.B. Papkovsky A low-volume platform for cell-respirometric screening based on quenched-luminescence oxygen sensing Biosens. Bioelectron. 19 2004 1529 1535
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1529-1535
    • Alderman, J.1    Hynes, J.2    Floyd, S.M.3    Kruger, J.4    O'Connor, R.5    Papkovsky, D.B.6
  • 3
    • 4344647114 scopus 로고    scopus 로고
    • Poly(decyl methacrylate)-based fluorescent PEBBLE swarm nanosensors for measuring dissolved oxygen in biosamples
    • Y. Cao, Y.E.L. Koo, and R. Kopelman Poly(decyl methacrylate)-based fluorescent PEBBLE swarm nanosensors for measuring dissolved oxygen in biosamples Analyst 129 2004 745 750
    • (2004) Analyst , vol.129 , pp. 745-750
    • Cao, Y.1    Koo, Y.E.L.2    Kopelman, R.3
  • 4
    • 0042998220 scopus 로고    scopus 로고
    • Visualization of enzyme-catalyzed reactions using pH indicators: Rapid screening of hydrolase libraries and estimation of the enantioselectivity
    • F. Moris-Varas, A. Shah, J. Aikens, N.P. Nadkarni, J.D. Rozzell, and D.C. Demirjian Visualization of enzyme-catalyzed reactions using pH indicators: rapid screening of hydrolase libraries and estimation of the enantioselectivity Bioorg. Med. Chem. 7 1999 2183 2188
    • (1999) Bioorg. Med. Chem. , vol.7 , pp. 2183-2188
    • Moris-Varas, F.1    Shah, A.2    Aikens, J.3    Nadkarni, N.P.4    Rozzell, J.D.5    Demirjian, D.C.6
  • 6
    • 0035916872 scopus 로고    scopus 로고
    • Quantitative screening method for hydrolases in MTPs using pH indicators: Determination of kinetic parameters by dynamic pH monitoring
    • G.T. John, and E. Heinzle Quantitative screening method for hydrolases in MTPs using pH indicators: determination of kinetic parameters by dynamic pH monitoring Biotechnol. Bioeng. 72 2001 620 627
    • (2001) Biotechnol. Bioeng. , vol.72 , pp. 620-627
    • John, G.T.1    Heinzle, E.2
  • 7
    • 0242501473 scopus 로고    scopus 로고
    • Integrated optical sensing of dissolved oxygen in microtiter plates: A novel tool for microbial cultivation
    • G.T. John, I. Klimant, C. Wittmann, and E. Heinzle Integrated optical sensing of dissolved oxygen in microtiter plates: a novel tool for microbial cultivation Biotechnol. Bioeng. 81 2003 829 836
    • (2003) Biotechnol. Bioeng. , vol.81 , pp. 829-836
    • John, G.T.1    Klimant, I.2    Wittmann, C.3    Heinzle, E.4
  • 8
    • 3342921887 scopus 로고    scopus 로고
    • On-line oxygen uptake rate and culture viability measurement of animal cell culture using MTPs with integrated oxygen sensors
    • R.R. Deshpande, and E. Heinzle On-line oxygen uptake rate and culture viability measurement of animal cell culture using MTPs with integrated oxygen sensors Biotechnol. Lett. 26 2004 763 767
    • (2004) Biotechnol. Lett. , vol.26 , pp. 763-767
    • Deshpande, R.R.1    Heinzle, E.2
  • 10
    • 2942596022 scopus 로고    scopus 로고
    • Method for determining oxygen consumption rates of static cultures from MTP measurements of pericellular dissolved oxygen concentration
    • R.D. Guarino, L.E. Dike, T.A. Haq, J.A. Rowley, J.B. Pitner, and M.R. Timmins Method for determining oxygen consumption rates of static cultures from MTP measurements of pericellular dissolved oxygen concentration Biotechnol. Bioeng. 86 2004 775 787
    • (2004) Biotechnol. Bioeng. , vol.86 , pp. 775-787
    • Guarino, R.D.1    Dike, L.E.2    Haq, T.A.3    Rowley, J.A.4    Pitner, J.B.5    Timmins, M.R.6
  • 11
    • 0036022002 scopus 로고    scopus 로고
    • Modeling of mixing in 96-well MTPs observed with fluorescence indicators
    • S. Weiss, G.T. John, I. Klimant, and E. Heinzle Modeling of mixing in 96-well MTPs observed with fluorescence indicators Biotechnol. Progr. 18 2002 821 830
    • (2002) Biotechnol. Progr. , vol.18 , pp. 821-830
    • Weiss, S.1    John, G.T.2    Klimant, I.3    Heinzle, E.4
  • 13
    • 0003542713 scopus 로고
    • J. Crank G.S. Park Academic Press London
    • V. Stannett J. Crank G.S. Park Diffusion in Polymers 1968 Academic Press London 1 73
    • (1968) Diffusion in Polymers , pp. 1-73
    • Stannett, V.1
  • 14
    • 20344389782 scopus 로고    scopus 로고
    • Gas sensing in MTPs with optodes - Influence of oxygen exchange between sample, air and plate material
    • S. Arain, S. Weiss, E. Heinzle, G.T. John, C. Krause, and I. Klimant Gas sensing in MTPs with optodes - influence of oxygen exchange between sample, air and plate material Biotechnol. Bioeng. 90 2005 271 280
    • (2005) Biotechnol. Bioeng. , vol.90 , pp. 271-280
    • Arain, S.1    Weiss, S.2    Heinzle, E.3    John, G.T.4    Krause, C.5    Klimant, I.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.