Volumn 81 A, Issue 1-4, 2006, Pages 701-705

Investigation of hydrogen isotope permeation through F82H steel with and without a ceramic coating of Cr2O3-SiO2 including CrPO4 (out-of-pile tests)

Author keywords

Ceramic coating; Deuterium; F82H; Hydrogen; Permeability; Permeation reduction factor

Indexed keywords

CERAMIC COATINGS; DIFFUSION; ISOTOPES; STEEL; SUBSTRATES;

EID: 31844431968     PISSN: 09203796     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.fusengdes.2005.07.019     Document Type: Conference Paper
Times cited : (49)

References (5)
  • 2
    • 0035520310 scopus 로고    scopus 로고
    • Characterization of chemical densified coating as tritium permeation barrier
    • M. Nakamichi, H. Kawamura, and T. Teratani Characterization of chemical densified coating as tritium permeation barrier J. Nucl. Sci. Technol. 38 2001 1007 1013
    • (2001) J. Nucl. Sci. Technol. , vol.38 , pp. 1007-1013
    • Nakamichi, M.1    Kawamura, H.2    Teratani, T.3
  • 4
    • 0031168737 scopus 로고    scopus 로고
    • Influence of traps on the deuterium behaviour in the low activation martensitic steels F82H and Batman
    • E. Serra, A. Perrujo, and G. Benamati Influence of traps on the deuterium behaviour in the low activation martensitic steels F82H and Batman J. Nucl. Mater. 245 1997 108 114
    • (1997) J. Nucl. Mater. , vol.245 , pp. 108-114
    • Serra, E.1    Perrujo, A.2    Benamati, G.3