메뉴 건너뛰기




Volumn 38, Issue 1, 2006, Pages 57-64

Validity and reproducibility of hand-held dynamometry in children aged 4-11 years

Author keywords

Children; Hand held dynamometry; Muscle; Myopathy; Strength

Indexed keywords

ANALYZER; ARTICLE; CHILD; CONTROLLED STUDY; CORRELATION COEFFICIENT; DYNAMOMETRY; FEMALE; HUMAN; LOGISTIC REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ERROR; MUSCLE FUNCTION; MUSCLE STRENGTH; MUSCLE TETANIC CONTRACTION; MYOPATHY; PATIENT REFERRAL; RECEIVER OPERATING CHARACTERISTIC; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TEST RETEST RELIABILITY; VALIDITY;

EID: 31744444690     PISSN: 00365505     EISSN: None     Source Type: Journal    
DOI: 10.1080/16501970510044043     Document Type: Article
Times cited : (49)

References (40)
  • 1
    • 0033862185 scopus 로고    scopus 로고
    • Muscle function assessment in children
    • Jones, MA and Stratton, G. (2000) Muscle function assessment in children Acta Paediatr, 89, pp. 753-761.
    • (2000) Acta Paediatr , vol.89 , pp. 753-761
    • Jones, M.A.1    Stratton, G.2
  • 2
    • 0024307535 scopus 로고
    • Isometric muscle force and anthropometric values in normal children aged between 3.5 and 15 years
    • Bäckman, E and Odenrick, P and Henriksson, KG and Ledin, T. (1989) Isometric muscle force and anthropometric values in normal children aged between 3.5 and 15 years Scand J Rehabil Med, 21, pp. 105-114.
    • (1989) Scand J Rehabil Med , vol.21 , pp. 105-114
    • Bäckman, E.1    Odenrick, P.2    Henriksson, K.G.3    Ledin, T.4
  • 3
    • 0034980532 scopus 로고    scopus 로고
    • Reference values of maximum isometric muscle force obtained in 270 children aged 4-16 years by hand-held dynamometry
    • BeenakkerEAC, HoevenJH van der, FockJM, MauritsNMReference values of maximum isometric muscle force obtained in 270 children aged 4-16 years by hand-held dynamometry. Neuromuscul Disord 2001; 11: 441-446.
    • (2001) Neuromuscul Disord , vol.11 , pp. 441-446
    • Beenakker, E.A.C.1    van der Hoeven, J.H.2    Fock, J.M.3    Maurits, N.M.4
  • 4
    • 72849182647 scopus 로고
    • Quantitative muscle testing: Principles and applications to research and clinical services
    • Beasley, WC. (1961) Quantitative muscle testing: Principles and applications to research and clinical services Arch Phys Med Rehabil, 42, pp. 398-425.
    • (1961) Arch Phys Med Rehabil , vol.42 , pp. 398-425
    • Beasley, W.C.1
  • 5
    • 0017337414 scopus 로고
    • Human skeletal muscle function: Description of tests and normal values
    • Edwards, RHT and Young, A and Hosking, GP and Jones, DA. (1977) Human skeletal muscle function: Description of tests and normal values Clin Sci Molec Med, 52, pp. 283-290.
    • (1977) Clin Sci Molec Med , vol.52 , pp. 283-290
    • Edwards, R.H.T.1    Young, A.2    Hosking, G.P.3    Jones, D.A.4
  • 7
    • 0029963026 scopus 로고    scopus 로고
    • Normative values for isometric muscle force measurements obtained with hand-held dynamometers
    • Andrews, AW and Thomas, MW and Bohannon, RW. (1996) Normative values for isometric muscle force measurements obtained with hand-held dynamometers Phys Ther, 76, pp. 248-259.
    • (1996) Phys Ther , vol.76 , pp. 248-259
    • Andrews, A.W.1    Thomas, M.W.2    Bohannon, R.W.3
  • 8
    • 0030448921 scopus 로고    scopus 로고
    • NIMS, The National Isometric Muscle Strength Database Consortium. Muscular weakness assessment: Use of normal isometric strength data
    • NIMS, The National Isometric Muscle Strength Database Consortium. Muscular weakness assessment: Use of normal isometric strength data Arch Phys Med Rehabil 1996; 77: 1251-1255.
    • (1996) Arch Phys Med Rehabil , vol.77 , pp. 1251-1255
  • 9
    • 0029030279 scopus 로고
    • Isometric muscle strength and muscular endurance in normal persons aged between 17 and 70 years
    • Bäckman, E and Johansson, J and Hager, B and Sjoblom, P and Henriksson, KG. (1995) Isometric muscle strength and muscular endurance in normal persons aged between 17 and 70 years Scand J Rehabil Med, 27, pp. 109-117.
    • (1995) Scand J Rehabil Med , vol.27 , pp. 109-117
    • Bäckman, E.1    Johansson, J.2    Hager, B.3    Sjoblom, P.4    Henriksson, K.G.5
  • 10
    • 0031021783 scopus 로고    scopus 로고
    • Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years
    • Bohannon, RW. (1997) Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years Arch Phys Med Rehabil, 78, pp. 26-32.
    • (1997) Arch Phys Med Rehabil , vol.78 , pp. 26-32
    • Bohannon, R.W.1
  • 13
    • 0017036587 scopus 로고
    • Measurements of muscle strength and performance in children with normal and diseased muscle
    • Hosking, GP and Bhat, US and Dubowitz, V and Edwards, RHT. (1976) Measurements of muscle strength and performance in children with normal and diseased muscle Arch Dis Child, 51, pp. 957-963.
    • (1976) Arch Dis Child , vol.51 , pp. 957-963
    • Hosking, G.P.1    Bhat, U.S.2    Dubowitz, V.3    Edwards, R.H.T.4
  • 14
    • 0019948028 scopus 로고
    • Quantitation of muscle function in children: A prospective study in Duchenne muscular dystrophy
    • Scott, OM and Hyde, SA and Goddard, C and Dubowitz, V. (1982) Quantitation of muscle function in children: A prospective study in Duchenne muscular dystrophy Muscle Nerve, 5, pp. 291-301.
    • (1982) Muscle Nerve , vol.5 , pp. 291-301
    • Scott, O.M.1    Hyde, S.A.2    Goddard, C.3    Dubowitz, V.4
  • 15
    • 0023886555 scopus 로고
    • Reliability of quantitative muscle testing in healthy children and in children with Duchenne muscular dystrophy using a hand-held dynamometer
    • Stuberg, WA and Metcalf, WK. (1988) Reliability of quantitative muscle testing in healthy children and in children with Duchenne muscular dystrophy using a hand-held dynamometer Phys Ther, 68, pp. 977-982.
    • (1988) Phys Ther , vol.68 , pp. 977-982
    • Stuberg, W.A.1    Metcalf, W.K.2
  • 17
    • 85048389224 scopus 로고    scopus 로고
    • Quantitative assessment of calf circumference in Duchenne muscular dystrophy patients
    • van den Beld, WA. (2003) Quantitative assessment of calf circumference in Duchenne muscular dystrophy patients Neuromuscul Disord, 13, pp. 426-427.
    • (2003) Neuromuscul Disord , vol.13 , pp. 426-427
    • van den Beld, W.A.1
  • 21
    • 0023863061 scopus 로고
    • Make tests and break tests of elbow flexor muscle strength
    • Bohannon, RW. (1988) Make tests and break tests of elbow flexor muscle strength Phys Ther, 68, pp. 193-194.
    • (1988) Phys Ther , vol.68 , pp. 193-194
    • Bohannon, R.W.1
  • 22
    • 0029819861 scopus 로고    scopus 로고
    • The influence of subject and test design on dynamometric measurements of extremity muscles
    • Keating, JL and Matyas, TA. (1996) The influence of subject and test design on dynamometric measurements of extremity muscles Phys Ther, 76, pp. 866-889.
    • (1996) Phys Ther , vol.76 , pp. 866-889
    • Keating, J.L.1    Matyas, T.A.2
  • 27
    • 0003532215 scopus 로고
    • The design and analysis of clinical experiments. Wiley series in probability and mathematical statistics
    • New Jersey: John Wiley and Sons
    • Fleiss, JL.(1986) The design and analysis of clinical experiments. Wiley series in probability and mathematical statistics. New Jersey: John Wiley and Sons.
    • (1986)
    • Fleiss, J.L.1
  • 29
    • 0037202550 scopus 로고    scopus 로고
    • Assessing intrarater, interrater and test-retest reliability of continuous measurements
    • Rousson, V and Gasser, T and Seifert, B. (2002) Assessing intrarater, interrater and test-retest reliability of continuous measurements Stat Med, 21, pp. 3431-3446.
    • (2002) Stat Med , vol.21 , pp. 3431-3446
    • Rousson, V.1    Gasser, T.2    Seifert, B.3
  • 30
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, JM and Altman, DG. (1986) Statistical methods for assessing agreement between two methods of clinical measurement Lancet, 8, pp. 307-310.
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 31
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • Shrout, PE and Fleiss, JL. (1979) Intraclass correlations: Uses in assessing rater reliability Psychol Bull, 86, pp. 420-428.
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 35
    • 2942618402 scopus 로고    scopus 로고
    • Factors affecting interpretation of reliability coefficients
    • Russek, L. (2004) Factors affecting interpretation of reliability coefficients J Orthop Sports Phys Ther, 34, pp. 341-349.
    • (2004) J Orthop Sports Phys Ther , vol.34 , pp. 341-349
    • Russek, L.1
  • 36
    • 15744385505 scopus 로고    scopus 로고
    • Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM
    • Weir, JP. (2005) Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM J Strength Cond Res, 19, pp. 231-240.
    • (2005) J Strength Cond Res , vol.19 , pp. 231-240
    • Weir, J.P.1
  • 37
    • 31744444143 scopus 로고    scopus 로고
    • SAS Institute Inc... SAS/STAT User's Guide, version 8. Cary North Carolina: SAS Institute Inc
    • SAS Institute Inc..(1999) SAS/STAT User's Guide, version 8. Cary North Carolina: SAS Institute Inc.
    • (1999)
  • 39
    • 0029975750 scopus 로고    scopus 로고
    • Statistics notes: Measurement error and correlation coefficients
    • Bland, JM and Altman, DG. (1996) Statistics notes: Measurement error and correlation coefficients BMJ, 313, pp. 41-42.
    • (1996) BMJ , vol.313 , pp. 41-42
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.