-
2
-
-
0031174809
-
The use of tomography for dental implant planning
-
A. Ekestubbe, K. Gröndahl, and H.-G. Gröndahl, "The use of tomography for dental implant planning," Dentomaxillofacial Radiol, vol. 26, pp. 206-213, 1997.
-
(1997)
Dentomaxillofacial Radiol
, vol.26
, pp. 206-213
-
-
Ekestubbe, A.1
Gröndahl, K.2
Gröndahl, H.-G.3
-
3
-
-
0036517591
-
Evaluation of tuned-aperture computed tomography in the detection of simulated periodontal defects
-
A. Ramesh, J. B. Ludlow, R. L. Webber, D. A. Tyndall, and D. Paquette, "Evaluation of tuned-aperture computed tomography in the detection of simulated periodontal defects," Oral Maxillofacial Radiol, vol. 93, pp. 341-349, 2002.
-
(2002)
Oral Maxillofacial Radiol
, vol.93
, pp. 341-349
-
-
Ramesh, A.1
Ludlow, J.B.2
Webber, R.L.3
Tyndall, D.A.4
Paquette, D.5
-
4
-
-
31644446558
-
-
The Quantitative Radiology (QR). [Online]
-
(2005) NewTom3G-Dental Volumetric Tomograph. The Quantitative Radiology (QR). [Online], Available: http://www.qrverona.it/htm/products.htm
-
(2005)
NewTom3G-dental Volumetric Tomograph
-
-
-
5
-
-
31644448867
-
-
J. Morita (USA) Corp. [Online]
-
(2005) 3-D Accuitomo XYZ Slice View Tomograph. J. Morita (USA) Corp. [Online]. Available: http://www.jmoritausa.com/threeD_accuitomo.asp
-
(2005)
3-D Accuitomo XYZ Slice View Tomograph
-
-
-
6
-
-
31644431838
-
-
Hitachi Medical Co. [Online]
-
(2005) CB Mercuray Dentomaxillofacial Cone Beam CT-System. Hitachi Medical Co. [Online]. Available: http://www.hitachi-medical.co.jp/english/ product/cbct/mercuray/index.html
-
(2005)
CB Mercuray Dentomaxillofacial Cone Beam CT-system
-
-
-
7
-
-
0022413669
-
Mathematical foundations of computed tomography
-
K. T. Smith and F. Keinert, "Mathematical foundations of computed tomography," Appl. Optics, vol. 24, pp. 3950-3957, 1985.
-
(1985)
Appl. Optics
, vol.24
, pp. 3950-3957
-
-
Smith, K.T.1
Keinert, F.2
-
9
-
-
0022368768
-
Algorithms for limited-view computed tomography: An annotated bibliography and a challenge
-
R. M. Ranggayyan, A. T. Dhawan, and R. Gordon, "Algorithms for limited-view computed tomography: an annotated bibliography and a challenge," Appl. Optics, vol. 24, pp. 4000-4012, 1985.
-
(1985)
Appl. Optics
, vol.24
, pp. 4000-4012
-
-
Ranggayyan, R.M.1
Dhawan, A.T.2
Gordon, R.3
-
11
-
-
0010264747
-
Bayesian and related methods in image reconstruction from incomplete data
-
Orlando, FL: Academic
-
K. M. Hanson, "Bayesian and related methods in image reconstruction from incomplete data," in Image Recovery: Theory and Applications. Orlando, FL: Academic, 1987.
-
(1987)
Image Recovery: Theory and Applications
-
-
Hanson, K.M.1
-
12
-
-
0028516435
-
Bayesian estimation of 3-D objects from few radiographs
-
Oct.
-
K. Sauer, S. James Jr., and K. Klifa, "Bayesian estimation of 3-D objects from few radiographs," IEEE Trans. Nucl. Sci., vol. 41, no. 5, pp. 1780-1790, Oct. 1994.
-
(1994)
IEEE Trans. Nucl. Sci.
, vol.41
, Issue.5
, pp. 1780-1790
-
-
Sauer, K.1
James Jr., S.2
Klifa, K.3
-
13
-
-
0020844872
-
Bayesian approach to limitedangle reconstruction in computed tomography
-
K. M. Hanson and G. W. Wecksung, "Bayesian approach to limitedangle reconstruction in computed tomography," J. Opt. Soc. Am., vol. 73, pp. 1501-1509, 1983.
-
(1983)
J. Opt. Soc. Am.
, vol.73
, pp. 1501-1509
-
-
Hanson, K.M.1
Wecksung, G.W.2
-
14
-
-
0027624429
-
A generalized Gaussian image model for edge-preserving MAP estimation
-
Jul.
-
C. Bouman and K. Sauer, "A generalized Gaussian image model for edge-preserving MAP estimation," IEEE Trans. Image Process., vol. 2, no. 3, pp. 296-310, Jul. 1993.
-
(1993)
IEEE Trans. Image Process.
, vol.2
, Issue.3
, pp. 296-310
-
-
Bouman, C.1
Sauer, K.2
-
15
-
-
0036651122
-
Adaptive wavelet graph model for Bayesian tomographic reconstruction
-
Jul.
-
T. Frese, C. Bouman, and K. Sauer, "Adaptive wavelet graph model for Bayesian tomographic reconstruction," IEEE Trans. Image Process., vol. 11, no. 7, pp. 756-770, Jul. 2002.
-
(2002)
IEEE Trans. Image Process.
, vol.11
, Issue.7
, pp. 756-770
-
-
Frese, T.1
Bouman, C.2
Sauer, K.3
-
16
-
-
0036462558
-
Edge-preserving tomographic reconstruction with nonlocal regularization
-
Feb.
-
D. F. Yu and J. A. Fessler, "Edge-preserving tomographic reconstruction with nonlocal regularization," IEEE Trans. Med. Imag., vol. 21, no. 2, pp. 159-173, Feb. 2002.
-
(2002)
IEEE Trans. Med. Imag.
, vol.21
, Issue.2
, pp. 159-173
-
-
Yu, D.F.1
Fessler, J.A.2
-
17
-
-
0037782046
-
Statistical inversion for medical X-ray tomography with few radiographs i: General theory
-
S. Siltanen, V. Kolehmainen, S. Järvenpää, J. P. Kaipio, P. Koistinen, M. Lassas, J. Pirttilä, and E. Somersalo, "Statistical inversion for medical X-ray tomography with few radiographs i: general theory," Phys. Med. Biol., vol. 48, pp. 1437-1463, 2003.
-
(2003)
Phys. Med. Biol.
, vol.48
, pp. 1437-1463
-
-
Siltanen, S.1
Kolehmainen, V.2
Järvenpää, S.3
Kaipio, J.P.4
Koistinen, P.5
Lassas, M.6
Pirttilä, J.7
Somersalo, E.8
-
18
-
-
0038119664
-
Statistical inversion for medical X-ray tomography with few radiographs ii: Application to dental radiology
-
V. Kolehmainen, S. Siltanen, S. Järvenpää, J. P. Kaipio, P. Koistinen, M. Lassas, J. Pirttilä, and E. Somersalo, "Statistical inversion for medical X-ray tomography with few radiographs ii: application to dental radiology," Phys. Med. Biol., vol. 48, pp. 1465-1490, 2003.
-
(2003)
Phys. Med. Biol.
, vol.48
, pp. 1465-1490
-
-
Kolehmainen, V.1
Siltanen, S.2
Järvenpää, S.3
Kaipio, J.P.4
Koistinen, P.5
Lassas, M.6
Pirttilä, J.7
Somersalo, E.8
-
19
-
-
0034298767
-
Parallelizable Bayesian tomography algorithms with rapid, quaranteed convergence
-
Oct.
-
J. Zheng, S. S. Saquib, K. Sauer, and C. A. Bouman, "Parallelizable Bayesian tomography algorithms with rapid, quaranteed convergence," IEEE Trans. Image. Process., vol. 9, no. 10, pp. 1745-1759, Oct. 2000.
-
(2000)
IEEE Trans. Image. Process.
, vol.9
, Issue.10
, pp. 1745-1759
-
-
Zheng, J.1
Saquib, S.S.2
Sauer, K.3
Bouman, C.A.4
-
20
-
-
0036608343
-
Monte carlo analysis of inverse problems
-
K. Mosegaard and M. Sambridge, "Monte carlo analysis of inverse problems," Im Probl., vol. 18, pp. R29-R54, 2002.
-
(2002)
Im Probl.
, vol.18
-
-
Mosegaard, K.1
Sambridge, M.2
-
22
-
-
0001341095
-
An image enhancement technique for electrical impedance tomography
-
D. C. Dobson and F. Santosa, "An image enhancement technique for electrical impedance tomography," Inv. Probl., vol. 10, pp. 317-334, 1994.
-
(1994)
Inv. Probl.
, vol.10
, pp. 317-334
-
-
Dobson, D.C.1
Santosa, F.2
-
23
-
-
0030212858
-
Recovery of blocky images from noisy and blurred data
-
D. C. Dobson and F. Santosa, "Recovery of blocky images from noisy and blurred data," SIAM J. Appl. Math., vol. 56, pp. 1181-1198, 1996.
-
(1996)
SIAM J. Appl. Math.
, vol.56
, pp. 1181-1198
-
-
Dobson, D.C.1
Santosa, F.2
-
24
-
-
0002712203
-
Maximum entropy and the nearly black object
-
D. L. Donoho, I. M. Johnstone, J. C. Hoch, and A. S. Stern, "Maximum entropy and the nearly black object," J. Roy, Statist. Ser. B, vol. 54, pp. 41-81, 1992.
-
(1992)
J. Roy, Statist. Ser. B
, vol.54
, pp. 41-81
-
-
Donoho, D.L.1
Johnstone, I.M.2
Hoch, J.C.3
Stern, A.S.4
-
25
-
-
0001531895
-
Two point step size gradient method
-
J. Barzilai and J. M. Borwein, "Two point step size gradient method," IMA J. Numer. Anal., vol. 8, pp. 141-148, 1988.
-
(1988)
IMA J. Numer. Anal.
, vol.8
, pp. 141-148
-
-
Barzilai, J.1
Borwein, J.M.2
-
26
-
-
0031542191
-
The Barzilai and Borwein gradient method for the large scale unconstrained minimization problem
-
M. Raydan, "The Barzilai and Borwein gradient method for the large scale unconstrained minimization problem," SIAM J. Optim., vol. 7, pp. 26-33, 1997.
-
(1997)
SIAM J. Optim.
, vol.7
, pp. 26-33
-
-
Raydan, M.1
-
28
-
-
0001861990
-
BEOWULF: A parallel workstation for scientific computation
-
T. Sterling, D. Savarese, D. J. Becker, J. E. Dorband, U. A. Ranawake, and C. V. Packer, "BEOWULF: a parallel workstation for scientific computation," in Proc. 24th Int. Conf. Parallel Processing, 1995.
-
(1995)
Proc. 24th Int. Conf. Parallel Processing
-
-
Sterling, T.1
Savarese, D.2
Becker, D.J.3
Dorband, J.E.4
Ranawake, U.A.5
Packer, C.V.6
-
29
-
-
0003660984
-
-
Argonne, IL: Argonne National Laboratory ANL-95/11
-
S. Balay, K. Buchelman, V. Eijkhout, W. D. Gropp, D. Kaushik, M. G. Knepley, L. C. Mclnnes, B. F. Smith, and H. Zhang, H. PETSc Users Manual (Revision 2.1.5). Argonne, IL: Argonne National Laboratory ANL-95/11.
-
H. PETSc Users Manual (Revision 2.1.5)
-
-
Balay, S.1
Buchelman, K.2
Eijkhout, V.3
Gropp, W.D.4
Kaushik, D.5
Knepley, M.G.6
Mclnnes, L.C.7
Smith, B.F.8
Zhang, H.9
-
30
-
-
0030243005
-
A high-performance, portable implementation of the MPI message passing interface standard
-
W. Gropp, E. Lusk, N. Doss, and A. Skjellum, "A high-performance, portable implementation of the MPI message passing interface standard," Parallel Computing, vol. 22, pp. 789-828, 1996.
-
(1996)
Parallel Computing
, vol.22
, pp. 789-828
-
-
Gropp, W.1
Lusk, E.2
Doss, N.3
Skjellum, A.4
-
31
-
-
0343462141
-
Automated empirical optimization of software and the ATLAS project
-
R. C. Whaley, A. Petitet, and J. J. Dongarra, "Automated empirical optimization of software and the ATLAS project," Parallel Computing, vol. 27, pp. 3-35, 2001.
-
(2001)
Parallel Computing
, vol.27
, pp. 3-35
-
-
Whaley, R.C.1
Petitet, A.2
Dongarra, J.J.3
-
32
-
-
0030621857
-
Tuned aperture computed tomography (TACT), theory and application for three-dimensional dento-alveolar imaging
-
R. L. Webber, R. A. Horton, D. A. Tyndall, and J. B. Ludlow, "Tuned aperture computed tomography (TACT), theory and application for three-dimensional dento-alveolar imaging," Dentomaxillofacial Radiol., vol. 26, pp. 53-62, 1997.
-
(1997)
Dentomaxillofacial Radiol.
, vol.26
, pp. 53-62
-
-
Webber, R.L.1
Horton, R.A.2
Tyndall, D.A.3
Ludlow, J.B.4
-
33
-
-
0033174609
-
An in vivo comparison of diagnostic information obtained from tuned-aperture computed tomography and conventional dental radiographic imaging modalities
-
R. L. Webber and J. K. Messura, "An in vivo comparison of diagnostic information obtained from tuned-aperture computed tomography and conventional dental radiographic imaging modalities," Oral Surg. Oral Med. Oral Pathol., vol. 88, pp. 239-247, 1999.
-
(1999)
Oral Surg. Oral Med. Oral Pathol.
, vol.88
, pp. 239-247
-
-
Webber, R.L.1
Messura, J.K.2
-
34
-
-
0031372061
-
Uncertainty assessment for reconstructions based on deformable geometry
-
K. M. Hanson, G. S. Cunningham, and R. McKee, "Uncertainty assessment for reconstructions based on deformable geometry," Int. J. Imag. Syst. Technol., vol. 8, pp. 506-512, 1997.
-
(1997)
Int. J. Imag. Syst. Technol.
, vol.8
, pp. 506-512
-
-
Hanson, K.M.1
Cunningham, G.S.2
McKee, R.3
|