메뉴 건너뛰기




Volumn 76, Issue 2, 2006, Pages 306-314

Effect of silver addition on the properties of nickel-titanium alloys for dental application

Author keywords

Corrosion resistance; Nickel titanium alloy; Shape memory; Silver; Superelasticity

Indexed keywords

CORROSION RESISTANCE; ELASTICITY; SILVER; SUPERCONDUCTING TRANSITION TEMPERATURE; X RAY DIFFRACTION ANALYSIS;

EID: 31544457887     PISSN: 00219304     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.30369     Document Type: Article
Times cited : (56)

References (39)
  • 2
    • 0012502687 scopus 로고
    • Martensitic transformations and mechanical effects
    • Olson GB, Owen WS, editors. Metals Park, OH: ASM International
    • Tamura I, Wayman CM. Martensitic transformations and mechanical effects. In: Olson GB, Owen WS, editors. Martensite. Metals Park, OH: ASM International; 1992. p 227-242.
    • (1992) Martensite , pp. 227-242
    • Tamura, I.1    Wayman, C.M.2
  • 3
    • 3042932626 scopus 로고
    • Shape memory materials
    • Yougi C, Hailing T, editors. Beijing: International Academic Publishers
    • Melton KN. Shape memory materials. In: Yougi C, Hailing T, editors. Shape memory alloys. Beijing: International Academic Publishers; 1994. p 523-529.
    • (1994) Shape Memory Alloys , pp. 523-529
    • Melton, K.N.1
  • 5
    • 11644307819 scopus 로고
    • Applications of shape memory effect
    • Besselink PA, Sachdeva RCL. Applications of shape memory effect. J Phys 1995;4:111-116.
    • (1995) J Phys , vol.4 , pp. 111-116
    • Besselink, P.A.1    Rcl, S.2
  • 6
    • 0035570621 scopus 로고    scopus 로고
    • Physichochemical and biological aspects of nitinol as a biomaterials
    • Shabalovskaya SA. Physichochemical and biological aspects of nitinol as a biomaterials. Int Mater Rev 2001;46:233-250.
    • (2001) Int Mater Rev , vol.46 , pp. 233-250
    • Shabalovskaya, S.A.1
  • 10
    • 0003241724 scopus 로고
    • Atomic absorption spectrometry in occupational and environmental health practice
    • Tsalev DL, editor. Boca Raton, FL: CRC Press
    • Zaprianov ZK. Atomic absorption spectrometry in occupational and environmental health practice. In: Tsalev DL, editor. Analytical aspects and health significance. Boca Raton, FL: CRC Press; 1983. Vol. 1.
    • (1983) Analytical Aspects and Health Significance , vol.1
    • Zaprianov, Z.K.1
  • 11
    • 1842648420 scopus 로고
    • Systemic biocompatibility of metallic surgical implants
    • Williams DF, editor. Boca Raton, FL: CRC Press
    • Smith GK. Systemic biocompatibility of metallic surgical implants. In: Williams DF, editor. Systemic biocompatibility of implant materials. Boca Raton, FL: CRC Press; 1981. Vol. 1.
    • (1981) Systemic Biocompatibility of Implant Materials , vol.1
    • Smith, G.K.1
  • 13
    • 0020012019 scopus 로고
    • Corrosion of orthodontic bracket bases
    • Maijer R, Smith DC. Corrosion of orthodontic bracket bases. Am J Orthod 1982;81:43-48.
    • (1982) Am J Orthod , vol.81 , pp. 43-48
    • Maijer, R.1    Smith, D.C.2
  • 14
    • 0022776331 scopus 로고
    • Biodegradation of the orthodontic bracket system
    • Maijer R, Smith DC. Biodegradation of the orthodontic bracket system. Am J Orthod 1986;90:195-198.
    • (1986) Am J Orthod , vol.90 , pp. 195-198
    • Maijer, R.1    Smith, D.C.2
  • 15
    • 0020808537 scopus 로고
    • In vitro release of nickel and chromium from simulated orthodontic appliances
    • Park HY, Shearer TR. In vitro release of nickel and chromium from simulated orthodontic appliances. Am J Orthod 1983;84: 156-159.
    • (1983) Am J Orthod , vol.84 , pp. 156-159
    • Park, H.Y.1    Shearer, T.R.2
  • 17
    • 0027342981 scopus 로고
    • Biodegradation of orthodontic appliance. Part 1. Biodegradation of nickel and chromium in vitro
    • Barrett RD, Bishara SE, Quinn JK. Biodegradation of orthodontic appliance. Part 1. Biodegradation of nickel and chromium in vitro. Am J Orthod Dentofacial Orthop 1993;103:8-14.
    • (1993) Am J Orthod Dentofacial Orthop , vol.103 , pp. 8-14
    • Barrett, R.D.1    Bishara, S.E.2    Quinn, J.K.3
  • 18
    • 0027548469 scopus 로고
    • Biodegradation of orthodontic appliance. Part 2. Changes in the blood level of nickel
    • Bishara SE, Barrett RD, Selim MI. Biodegradation of orthodontic appliance. Part 2. Changes in the blood level of nickel. Am J Orthod Dentofacial Orthop 1993;103:115-119.
    • (1993) Am J Orthod Dentofacial Orthop , vol.103 , pp. 115-119
    • Bishara, S.E.1    Barrett, R.D.2    Selim, M.I.3
  • 19
    • 0029183960 scopus 로고
    • In vitro release of nickel and chromium from different types of simulated orthodontic appliances
    • Kerosuo H, Moe G, Kleven E. In vitro release of nickel and chromium from different types of simulated orthodontic appliances. Angle Orthod 1995;65:111-116.
    • (1995) Angle Orthod , vol.65 , pp. 111-116
    • Kerosuo, H.1    Moe, G.2    Kleven, E.3
  • 20
    • 0038384453 scopus 로고    scopus 로고
    • Ion release from NiTi orthodontic wires in artificial saliva with various acidities
    • Huang HH, Chiu YH, Lee TH, Wu SC, Yang HW, Su KH, Hsu CC. Ion release from NiTi orthodontic wires in artificial saliva with various acidities. Biomaterials 2003;24:3585-3592.
    • (2003) Biomaterials , vol.24 , pp. 3585-3592
    • Huang, H.H.1    Chiu, Y.H.2    Lee, T.H.3    Wu, S.C.4    Yang, H.W.5    Su, K.H.6    Hsu, C.C.7
  • 21
    • 0024728095 scopus 로고
    • Contact dermatitis from nickel: An investigation of its sources
    • Romaguera C, Vilaplana J, Grimalt F. Contact dermatitis from nickel: an investigation of its sources. Contact Dermatitis 1989;21:204.
    • (1989) Contact Dermatitis , vol.21 , pp. 204
    • Romaguera, C.1    Vilaplana, J.2    Grimalt, F.3
  • 22
    • 0023858796 scopus 로고
    • Short Communication: Nickel sensitivity from dental prosthesis
    • Temesvari E, Racz I. Short Communication: Nickel sensitivity from dental prosthesis. Contact Dermatitis 1988;18:50-51.
    • (1988) Contact Dermatitis , vol.18 , pp. 50-51
    • Temesvari, E.1    Racz, I.2
  • 24
    • 2642582913 scopus 로고    scopus 로고
    • Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
    • Ryhanen J, Niemi E, Serlo W, Niemela E, Sandvik P, Pernu H, Salo T. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res 1996;35:451-457.
    • (1996) J Biomed Mater Res , vol.35 , pp. 451-457
    • Ryhanen, J.1    Niemi, E.2    Serlo, W.3    Niemela, E.4    Sandvik, P.5    Pernu, H.6    Salo, T.7
  • 25
    • 0035570621 scopus 로고    scopus 로고
    • Physicochemical and biological aspects of nitinol as a biomaterial
    • Shabalovskaya SA. Physicochemical and biological aspects of nitinol as a biomaterial. Int Mater Rev 2001;46:233-250.
    • (2001) Int Mater Rev , vol.46 , pp. 233-250
    • Shabalovskaya, S.A.1
  • 28
    • 0034901371 scopus 로고    scopus 로고
    • Effect of nickel-titanium shape memory metal alloy on bone formation
    • Kapanen A, Ryhanen J, Danilov A, Tuukkanen J. Effect of nickel-titanium shape memory metal alloy on bone formation. Biomaterials 2001;22:2475-2480.
    • (2001) Biomaterials , vol.22 , pp. 2475-2480
    • Kapanen, A.1    Ryhanen, J.2    Danilov, A.3    Tuukkanen, J.4
  • 29
    • 0033167966 scopus 로고    scopus 로고
    • Bone modeling and cell-material interface responses induced by nickel-titanium shape memory alloy after periosteal implantation
    • Ryhanen J, Kallioinen M, Tuukkanen J, Lehenkari P, Junila J, Niemela E, Sandvik P, Serlo W. Bone modeling and cell-material interface responses induced by nickel-titanium shape memory alloy after periosteal implantation. Biomaterials 1999; 20:1309-1317.
    • (1999) Biomaterials , vol.20 , pp. 1309-1317
    • Ryhanen, J.1    Kallioinen, M.2    Tuukkanen, J.3    Lehenkari, P.4    Junila, J.5    Niemela, E.6    Sandvik, P.7    Serlo, W.8
  • 30
    • 0023567506 scopus 로고
    • Metal release from heat-treated orthodontic archwires
    • Gjerdet NR, Hero H. Metal release from heat-treated orthodontic archwires. Acta Odontol Scand 1987;45:409-414.
    • (1987) Acta Odontol Scand , vol.45 , pp. 409-414
    • Gjerdet, N.R.1    Hero, H.2
  • 31
    • 0024723970 scopus 로고
    • Corrosion of dental copper, nickel, and gold alloys in artificial saliva and saline solutions
    • Johansson BI, Lemons JE, Hao SQ. Corrosion of dental copper, nickel, and gold alloys in artificial saliva and saline solutions. Dent Mater 1989;5:324.
    • (1989) Dent Mater , vol.5 , pp. 324
    • Johansson, B.I.1    Lemons, J.E.2    Hao, S.Q.3
  • 33
    • 31544453462 scopus 로고
    • Characteristics and applications of nickel-titanium shape memory alloy
    • Hahn KH, Rhee SS, Kim JW, Lee DH. Characteristics and applications of nickel-titanium shape memory alloy. Bull Korean Inst Metals 1991;4:36.
    • (1991) Bull Korean Inst Metals , vol.4 , pp. 36
    • Hahn, K.H.1    Rhee, S.S.2    Kim, J.W.3    Lee, D.H.4
  • 35
    • 0001927040 scopus 로고
    • Shape memory and transformation behavior of martensitic Ti-Pd-Ni and Ti-Pt-Ni alloys
    • Duerig TW et al., editors. London: Butterworth-Heinemann
    • Lindquist PG, Wayman CM. Shape memory and transformation behavior of martensitic Ti-Pd-Ni and Ti-Pt-Ni alloys. In: Duerig TW et al., editors. Engineering aspects of shape memory alloys. London: Butterworth-Heinemann; 1990. p 58.
    • (1990) Engineering Aspects of Shape Memory Alloys , pp. 58
    • Lindquist, P.G.1    Wayman, C.M.2
  • 36
    • 0026844581 scopus 로고
    • In vitro corrosion behavior of 13 prosthodontic alloys
    • Senay C, Mujgan O. In vitro corrosion behavior of 13 prosthodontic alloys. Quintessence Int 1992;23:279-287.
    • (1992) Quintessence Int , vol.23 , pp. 279-287
    • Senay, C.1    Mujgan, O.2
  • 37
    • 0033289498 scopus 로고    scopus 로고
    • In vitro corrosion behavior and metallic ion release of different prothodontic alloys
    • Gil FJ, Sanchez LA, Espias A, Planell JA. In vitro corrosion behavior and metallic ion release of different prothodontic alloys. Int Dent J 1999;49:361-367.
    • (1999) Int Dent J , vol.49 , pp. 361-367
    • Gil, F.J.1    Sanchez, L.A.2    Espias, A.3    Planell, J.A.4
  • 38
    • 0019194061 scopus 로고
    • Tissue accumulation of nickel released due to electrochemical corrosion of non-precious dental casting alloys
    • Bergman M, Bergman B, Soremark R. Tissue accumulation of nickel released due to electrochemical corrosion of non-precious dental casting alloys. J Oral Rehab 1980;7:325-330.
    • (1980) J Oral Rehab , vol.7 , pp. 325-330
    • Bergman, M.1    Bergman, B.2    Soremark, R.3
  • 39
    • 0033134849 scopus 로고    scopus 로고
    • Corrosion and biocompatibility of orthodontic wires
    • Widu F, Drecher D, Junker R. Corrosion and biocompatibility of orthodontic wires. J Mater Sci Mater Med 1999;10: 275-281.
    • (1999) J Mater Sci Mater Med , vol.10 , pp. 275-281
    • Widu, F.1    Drecher, D.2    Junker, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.