메뉴 건너뛰기




Volumn 55, Issue 1, 2006, Pages 5-12

Recent advances in airway management devices

Author keywords

Airway devices; Airway management; Difficult airway

Indexed keywords

AIRWAY; ASSISTED VENTILATION; CLINICAL DECISION MAKING; DEVICE; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; JET VENTILATION; LARYNGEAL MASK; LARYNGOSCOPE; REVIEW;

EID: 31544441640     PISSN: 00214892     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (1)

References (17)
  • 2
    • 0037406762 scopus 로고    scopus 로고
    • An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Practice guidelines for management of the difficult airway
    • An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Practice guidelines for management of the difficult airway. Anesthesiology 2003; 98: 1269-77.
    • (2003) Anesthesiology , vol.98 , pp. 1269-1277
  • 3
    • 0002869627 scopus 로고    scopus 로고
    • Laryngoscopes
    • Dorsch JA, Dorsch SE, editors. Philadelphia: Lippincott Williams & Wilkins
    • th ed. Philadelphia: Lippincott Williams & Wilkins; 1997. p.505-56.
    • (1997) th Ed. , pp. 505-556
    • Dorsch, J.A.1    Dorsch, S.E.2
  • 5
    • 15944396119 scopus 로고    scopus 로고
    • A comparison of 20 laryngoscope blades using an intubating manikin: Visual analogue scores and forces exerted during laryngoscopy
    • Rassman S, Wilkes AR, Hall JE, Mecklenburgh JS. A comparison of 20 laryngoscope blades using an intubating manikin: visual analogue scores and forces exerted during laryngoscopy. Anaesthesia 2005; 60: 384-94.
    • (2005) Anaesthesia , vol.60 , pp. 384-394
    • Rassman, S.1    Wilkes, A.R.2    Hall, J.E.3    Mecklenburgh, J.S.4
  • 6
    • 0030967407 scopus 로고    scopus 로고
    • The use of paraglossal straight blade laryngoscopy in difficult tracheal intubation
    • Henderson JJ. The use of paraglossal straight blade laryngoscopy in difficult tracheal intubation. Anaesthesia 1997; 52: 552-60.
    • (1997) Anaesthesia , vol.52 , pp. 552-560
    • Henderson, J.J.1
  • 7
    • 31544462518 scopus 로고    scopus 로고
    • Japanese source
  • 9
    • 0037236215 scopus 로고    scopus 로고
    • Variant Creutzfeldt-Jacob disease and disposable anaesthetic equipment-balancing the risks
    • Blunt MC, Burchett KR. Variant Creutzfeldt-Jacob disease and disposable anaesthetic equipment-balancing the risks. Br J Anaesth 2003; 90: 1-3.
    • (2003) Br J Anaesth , vol.90 , pp. 1-3
    • Blunt, M.C.1    Burchett, K.R.2
  • 10
    • 31544467741 scopus 로고    scopus 로고
    • Truview® blade improves laryngeal view compared to Macintosh blade
    • Lieberman N, Hakim AR, Berkenstat H. Truview® blade improves laryngeal view compared to Macintosh blade [Abstract]. ASA meeting; 2003: A-565.
    • (2003) ASA Meeting
    • Lieberman, N.1    Hakim, A.R.2    Berkenstat, H.3
  • 11
    • 31544437926 scopus 로고    scopus 로고
    • Japanese source
  • 12
    • 4444265228 scopus 로고    scopus 로고
    • Tracheal tubes
    • Dorsch JA, Dorsch SE, editors. Philadelphia: Lippincott Williams & Wilkins
    • th ed. Philadelphia: Lippincott Williams & Wilkins; 1997. p.557-671.
    • (1997) th Ed. , pp. 557-671
    • Dorsch, J.A.1    Dorsch, S.E.2
  • 13
    • 31544434159 scopus 로고    scopus 로고
    • Chinese source
  • 14
    • 31544445150 scopus 로고    scopus 로고
    • Chinese source
  • 15
    • 31544450169 scopus 로고    scopus 로고
    • Chinese source
  • 16
    • 31544469087 scopus 로고    scopus 로고
    • Chinese source
  • 17
    • 3242884152 scopus 로고    scopus 로고
    • Difficult Airway Society guidelines for management of the unanticipated difficult intubation
    • Henderson JJ, Popat MT, Latto LP, Pearce AC. Difficult Airway Society guidelines for management of the unanticipated difficult intubation. Anaesthesia 2004; 59: 675-94.
    • (2004) Anaesthesia , vol.59 , pp. 675-694
    • Henderson, J.J.1    Popat, M.T.2    Latto, L.P.3    Pearce, A.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.