메뉴 건너뛰기




Volumn 23, Issue 8, 2005, Pages 539-544

Image quality of high-resolution CT with 16-channel multidetector-row CT: Comparison between helical scan and conventional step-shoot scan

Author keywords

Diffuse lung disease; High resolution computed tomography; Lung; Multidetector row computed tomography

Indexed keywords

ARTICLE; AUTOPSY; COMPUTED TOMOGRAPHY SCANNER; DIAGNOSTIC ACCURACY; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; LUNG DISEASE; MULTIDETECTOR COMPUTED TOMOGRAPHY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; VOLUMETRY;

EID: 31444437390     PISSN: 02882043     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (28)
  • 1
    • 0002556880 scopus 로고    scopus 로고
    • Technical aspects of high-resolution computed tomography
    • John JR ed.; Lippincott Williams & Wilkins, Philadelphia
    • Webb WR, Muller NL, Naidich DP. Technical aspects of high-resolution computed tomography. In High-Resolution CT of the Lung, 3rd ed. (John JR ed.; Lippincott Williams & Wilkins, Philadelphia), pp. 1-47, 2001.
    • (2001) High-Resolution CT of the Lung, 3rd Ed. , pp. 1-47
    • Webb, W.R.1    Muller, N.L.2    Naidich, D.P.3
  • 2
    • 0023220989 scopus 로고
    • High-resolution CT of the lungs: An optimal approach
    • Mayo JR, Webb WR, Gould R, et al. High-resolution CT of the lungs: an optimal approach. Radiology, 163: 507-510, 1987.
    • (1987) Radiology , vol.163 , pp. 507-510
    • Mayo, J.R.1    Webb, W.R.2    Gould, R.3
  • 3
    • 0025827253 scopus 로고
    • High resolution computed tomography. Technical aspects
    • Mayo JR. High resolution computed tomography. Technical aspects. Radiol Clin North Am, 29: 1043-1049, 1991.
    • (1991) Radiol Clin North Am , vol.29 , pp. 1043-1049
    • Mayo, J.R.1
  • 5
    • 0022386081 scopus 로고
    • Diffuse peripheral lung disease: Evaluation by high-resolution computed tomography
    • Nakata H, Kimoto T, Nakayama T, Kido M, Miyazaki N, Harada S. Diffuse peripheral lung disease: evaluation by high-resolution computed tomography. Radiology, 157: 181-185, 1985.
    • (1985) Radiology , vol.157 , pp. 181-185
    • Nakata, H.1    Kimoto, T.2    Nakayama, T.3    Kido, M.4    Miyazaki, N.5    Harada, S.6
  • 6
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology, 176: 181-183, 1990.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 7
    • 0032718470 scopus 로고    scopus 로고
    • Performance evaluation of a multi-slice CT system
    • McCollough CH, Zink FE. Performance evaluation of a multi-slice CT system. Med Phys, 26: 2223-2230, 1999.
    • (1999) Med Phys , vol.26 , pp. 2223-2230
    • McCollough, C.H.1    Zink, F.E.2
  • 8
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys, 26: 5-18, 1999.
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 9
    • 0034330627 scopus 로고    scopus 로고
    • Multisection CT: Scanning techniques and clinical applications
    • Rydberg J, Buckwalter KA, Caldemeyer KS, et al. Multisection CT: scanning techniques and clinical applications. Radiographics, 20: 1787-1806, 2000.
    • (2000) Radiographics , vol.20 , pp. 1787-1806
    • Rydberg, J.1    Buckwalter, K.A.2    Caldemeyer, K.S.3
  • 11
    • 85008987259 scopus 로고    scopus 로고
    • This joint statement of the American Thoracic Society (ATS), and the European Respiratory Society (ERS) was adopted by the ATS board of directors, June 2001 and by the ERS Executive Committee, June 2001
    • American Thoracic Society/European Respiratory Society International Multidisciplinary Consensus Classification of the Idiopathic Interstitial Pneumonias. This joint statement of the American Thoracic Society (ATS), and the European Respiratory Society (ERS) was adopted by the ATS board of directors, June 2001 and by the ERS Executive Committee, June 2001.Am J Respir Crit Care Med, 165: 277-304, 2002.
    • (2002) Am J Respir Crit Care Med , vol.165 , pp. 277-304
  • 12
    • 0027303953 scopus 로고
    • Computed tomography of diffuse pulmonary haemorrhage with pathological correlation
    • Cheah FK, Sheppard MN, Hansell DM. Computed tomography of diffuse pulmonary haemorrhage with pathological correlation. Clin Radiol, 48: 89-93, 1993.
    • (1993) Clin Radiol , vol.48 , pp. 89-93
    • Cheah, F.K.1    Sheppard, M.N.2    Hansell, D.M.3
  • 13
    • 0027296254 scopus 로고
    • Appearance of pulmonary metastases on high-resolution CT scans: Comparison with histopathologic findings from autopsy specimens
    • Hirakata K, Nakata H, Haratake J. Appearance of pulmonary metastases on high-resolution CT scans: comparison with histopathologic findings from autopsy specimens. AJR Am J Roentgenol, 161: 37-43, 1993.
    • (1993) AJR Am J Roentgenol , vol.161 , pp. 37-43
    • Hirakata, K.1    Nakata, H.2    Haratake, J.3
  • 14
    • 0029057513 scopus 로고
    • CT in adults with tuberculosis of the chest: Characteristic findings and role in management
    • Lee KS, Im JG. CT in adults with tuberculosis of the chest: characteristic findings and role in management. AJR Am J Roentgenol, 164: 1361-1367, 1995.
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 1361-1367
    • Lee, K.S.1    Im, J.G.2
  • 15
    • 0023831367 scopus 로고
    • Pulmonary lymphangitic carcinomatosis: CT and pathologic findings
    • Munk PL, Muller NL, Miller RR, Ostrow DN. Pulmonary lymphangitic carcinomatosis: CT and pathologic findings. Radiology, 166: 705-709, 1988.
    • (1988) Radiology , vol.166 , pp. 705-709
    • Munk, P.L.1    Muller, N.L.2    Miller, R.R.3    Ostrow, D.N.4
  • 16
    • 0023037363 scopus 로고
    • Centrilobular lesions of the lung: Demonstration by high-resolution CT and pathologic correlation
    • Murata K, Itoh H, Todo G, et al. Centrilobular lesions of the lung: demonstration by high-resolution CT and pathologic correlation. Radiology, 161: 641-645, 1986.
    • (1986) Radiology , vol.161 , pp. 641-645
    • Murata, K.1    Itoh, H.2    Todo, G.3
  • 17
    • 0026686843 scopus 로고
    • Diffuse panbronchiolitis: Correlation of high-resolution CT and pathologic findings
    • Nishimura K, Kitaichi M, Izumi T, Itoh H. Diffuse panbronchiolitis: correlation of high-resolution CT and pathologic findings. Radiology, 184: 779-785, 1992.
    • (1992) Radiology , vol.184 , pp. 779-785
    • Nishimura, K.1    Kitaichi, M.2    Izumi, T.3    Itoh, H.4
  • 19
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • Polacin A, Kalender WA, Marchal G. Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology, 185: 29-35, 1992.
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 20
    • 0025179432 scopus 로고
    • Lung: Spiral volumetric CT with single-breath-hold technique
    • Vock P, Soucek M, Daepp M, Kalender WA. Lung: spiral volumetric CT with single-breath-hold technique. Radiology, 176: 864-867, 1990.
    • (1990) Radiology , vol.176 , pp. 864-867
    • Vock, P.1    Soucek, M.2    Daepp, M.3    Kalender, W.A.4
  • 21
    • 0034989937 scopus 로고    scopus 로고
    • Multislice helical CT of focal and diffuse lung disease: Comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan
    • Schoepf UJ, Bruening RD, Hong C, et al. Multislice helical CT of focal and diffuse lung disease: comprehensive diagnosis with reconstruction of contiguous and high-resolution CT sections from a single thin-collimation scan. AJR Am J Roentgenol, 177: 179-184, 2001.
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 179-184
    • Schoepf, U.J.1    Bruening, R.D.2    Hong, C.3
  • 22
    • 0034829189 scopus 로고    scopus 로고
    • High-resolution CT using multidetector CT equipment: Evaluation of image quality in 11 cadaveric lungs and a phantom
    • Honda O, Johkoh T, Tomiyama N, et al. High-resolution CT using multidetector CT equipment: evaluation of image quality in 11 cadaveric lungs and a phantom. AJR Am J Roentgenol, 177: 875-879, 2001.
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 875-879
    • Honda, O.1    Johkoh, T.2    Tomiyama, N.3
  • 23
    • 0022262949 scopus 로고
    • Enhanced pancreatic CT imaging utilizing a geometric magnification technique
    • Clark LR, Jacobs NM, Zeman RK, et al. Enhanced pancreatic CT imaging utilizing a geometric magnification technique. Invest Radiol, 20: 531-538, 1985.
    • (1985) Invest Radiol , vol.20 , pp. 531-538
    • Clark, L.R.1    Jacobs, N.M.2    Zeman, R.K.3
  • 24
    • 0028072590 scopus 로고
    • CT of the chest and abdomen in patients on mechanical pulmonary ventilators: Quality of images made at 0.6 vs 1.0 sec
    • Posniak HV, Olson MC, Demos TC, Pierce KL, Kalbhen CL. CT of the chest and abdomen in patients on mechanical pulmonary ventilators: quality of images made at 0.6 vs 1.0 sec. AJR Am J Roentgenol, 163: 1073-1077, 1994.
    • (1994) AJR Am J Roentgenol , vol.163 , pp. 1073-1077
    • Posniak, H.V.1    Olson, M.C.2    Demos, T.C.3    Pierce, K.L.4    Kalbhen, C.L.5
  • 25
    • 0023640941 scopus 로고
    • The double-fissure sign: A motion artifact on thin-section CT scans
    • Mayo JR, Muller NL, Henkelman RM. The double-fissure sign: a motion artifact on thin-section CT scans. Radiology, 165: 580-581, 1987.
    • (1987) Radiology , vol.165 , pp. 580-581
    • Mayo, J.R.1    Muller, N.L.2    Henkelman, R.M.3
  • 27
    • 1442305589 scopus 로고    scopus 로고
    • High-resolution CT using MDCT: Comparison of degree of motion artifact between volumetric and axial methods
    • Kelly DM, Hasegawa I, Borders R, Hatabu H, Boiselle PM. High-resolution CT using MDCT: comparison of degree of motion artifact between volumetric and axial methods. AJR Am J Roentgenol, 182: 757-759, 2004.
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 757-759
    • Kelly, D.M.1    Hasegawa, I.2    Borders, R.3    Hatabu, H.4    Boiselle, P.M.5
  • 28
    • 0035187964 scopus 로고    scopus 로고
    • Dose and pitch relationship for a particular multislice CT scanner
    • Mahesh M, Scatarige JC, Cooper J, Fishman EK. Dose and pitch relationship for a particular multislice CT scanner. AJR Am J Roentgenol, 177: 1273-1275, 2001.
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 1273-1275
    • Mahesh, M.1    Scatarige, J.C.2    Cooper, J.3    Fishman, E.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.