메뉴 건너뛰기




Volumn 19, Issue 12, 2005, Pages 1290-1296

The effect of flap thickness on the visual and refractive outcome of myopic laser in situ keratomileusis

Author keywords

Flap; LASIK; Myopia; Outcome; Thickness

Indexed keywords

ADULT; ARTICLE; EYE REFRACTION; FEMALE; FOLLOW UP; HUMAN; KERATOMILEUSIS; LINEAR REGRESSION ANALYSIS; LOGISTIC REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MALE; MYOPIA; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; RETROSPECTIVE STUDY; SAFETY; SURGICAL TECHNIQUE; TISSUE FLAP; TREATMENT OUTCOME; VISUAL ACUITY;

EID: 31444433019     PISSN: 0950222X     EISSN: 14765454     Source Type: Journal    
DOI: 10.1038/sj.eye.6701775     Document Type: Article
Times cited : (24)

References (54)
  • 2
    • 0042205396 scopus 로고    scopus 로고
    • Practice styles and preferences of ASCRS members-2002 survey
    • Leaming DV. Practice styles and preferences of ASCRS members-2002 survey. J Cataract Refract Surg 2003; 29: 1412-1420.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1412-1420
    • Leaming, D.V.1
  • 3
    • 0036237923 scopus 로고    scopus 로고
    • Corneal flap thickness in laser in situ keratomileusis using the summit Krumeich-Barraquer microkeratome
    • Ucakhan OO. Corneal flap thickness in laser in situ keratomileusis using the summit Krumeich-Barraquer microkeratome. J Cataract Refract Surg 2002; 28: 798-804.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 798-804
    • Ucakhan, O.O.1
  • 4
    • 0032789771 scopus 로고    scopus 로고
    • Corneal flap thickness in laser in situ keratomileusis using an SCMD manual microkeratome
    • Yi WM, Joo CK. Corneal flap thickness in laser in situ keratomileusis using an SCMD manual microkeratome. J Cataract Refract Surg 1999; 25: 1087-1092.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1087-1092
    • Yi, W.M.1    Joo, C.K.2
  • 5
    • 0034537228 scopus 로고    scopus 로고
    • Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome
    • Yildirim R, Aras C, Ozdamar A, Bahcecioglu H, Ozkan S. Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg 2000; 26: 1729-1732.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1729-1732
    • Yildirim, R.1    Aras, C.2    Ozdamar, A.3    Bahcecioglu, H.4    Ozkan, S.5
  • 6
    • 0035989292 scopus 로고    scopus 로고
    • Factors that affect corneal flap thickness with the Hansatome microkeratome
    • Gailitis RP, Lagzdins M. Factors that affect corneal flap thickness with the Hansatome microkeratome. J Refract Surg 2002; 18: 439-443.
    • (2002) J Refract Surg , vol.18 , pp. 439-443
    • Gailitis, R.P.1    Lagzdins, M.2
  • 7
    • 0036583902 scopus 로고    scopus 로고
    • 2000 microkeratome clinical evaluation
    • Arbelaez MC. Nidek MK 2000 microkeratome clinical evaluation. J Refract Surg 2002; 18: S357-S360.
    • (2002) J Refract Surg , vol.18
    • Arbelaez, M.C.1    Nidek, M.K.2
  • 8
    • 0035468467 scopus 로고    scopus 로고
    • Flap analysis: Critical point in laser in situ keratomileusis
    • Srivannaboon S. Flap analysis: Critical point in laser in situ keratomileusis. J Med Assoc Thai 2001; 84: 1317-1320.
    • (2001) J Med Assoc Thai , vol.84 , pp. 1317-1320
    • Srivannaboon, S.1
  • 10
    • 0036579844 scopus 로고    scopus 로고
    • Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes
    • Shemesh G, Dotan G, Lipshitz I. Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes. J Refract Surg 2002; 18: S347-S351.
    • (2002) J Refract Surg , vol.18
    • Shemesh, G.1    Dotan, G.2    Lipshitz, I.3
  • 11
    • 0031779852 scopus 로고    scopus 로고
    • Iatrogenic keratectasia after laser in situ keratomileusis
    • Seiler T, Koufala K, Richter G. Iatrogenic keratectasia after laser in situ keratomileusis. J Refract Surg 1998; 14: 312-317.
    • (1998) J Refract Surg , vol.14 , pp. 312-317
    • Seiler, T.1    Koufala, K.2    Richter, G.3
  • 12
    • 0035213062 scopus 로고    scopus 로고
    • Iatrogenic keratectasia after a deep primary keratotomy during laser in situ keratomileusis
    • Haw WW, Manche EE. Iatrogenic keratectasia after a deep primary keratotomy during laser in situ keratomileusis. Am J Ophthalmol 2001; 132: 920-921.
    • (2001) Am J Ophthalmol , vol.132 , pp. 920-921
    • Haw, W.W.1    Manche, E.E.2
  • 13
    • 0036894466 scopus 로고    scopus 로고
    • Epithelial ingrowth after laser in situ keratomileusis: Clinical features and possible mechanisms
    • Asano-Kato N, Toda I, Hori-Komai Y, Takano Y, Tsubota K. Epithelial ingrowth after laser in situ keratomileusis: Clinical features and possible mechanisms. Am J Ophthalmol 2002; 134: 801-807.
    • (2002) Am J Ophthalmol , vol.134 , pp. 801-807
    • Asano-Kato, N.1    Toda, I.2    Hori-Komai, Y.3    Takano, Y.4    Tsubota, K.5
  • 14
    • 0034813361 scopus 로고    scopus 로고
    • LASIK complications: Etiology, management, and prevention
    • Melki SA, Azar DT. LASIK complications: Etiology, management, and prevention. Surv Ophthalmol 2001; 46: 95-116.
    • (2001) Surv Ophthalmol , vol.46 , pp. 95-116
    • Melki, S.A.1    Azar, D.T.2
  • 15
    • 0036136894 scopus 로고    scopus 로고
    • Laser in situ keratomileusis intraoperative complications using one type of microkeratome
    • Pallikaris IG, Katsanevaki VJ, Panagopoulou SI. Laser in situ keratomileusis intraoperative complications using one type of microkeratome. Ophthalmology 2002; 109: 57-63.
    • (2002) Ophthalmology , vol.109 , pp. 57-63
    • Pallikaris, I.G.1    Katsanevaki, V.J.2    Panagopoulou, S.I.3
  • 16
    • 0141643160 scopus 로고    scopus 로고
    • Stromal haze after laser in situ keratomileusis: Clinical and confocal microscopy findings
    • Buhren J, Kohnen T. Stromal haze after laser in situ keratomileusis: clinical and confocal microscopy findings. J Cataract Refract Surg 2003; 29: 1718-1726.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1718-1726
    • Buhren, J.1    Kohnen, T.2
  • 17
    • 0036987830 scopus 로고    scopus 로고
    • Clinical feature of unintended thin corneal flap in LASIK: 1-year follow-up
    • Yeo HE, Song BJ. Clinical feature of unintended thin corneal flap in LASIK: 1-year follow-up. Korean J Ophthalmol 2002; 16: 63-69.
    • (2002) Korean J Ophthalmol , vol.16 , pp. 63-69
    • Yeo, H.E.1    Song, B.J.2
  • 19
    • 0030793930 scopus 로고    scopus 로고
    • Proper method for calculating average visual acuity
    • Holladay JT. Proper method for calculating average visual acuity. J Refract Surg 1997; 13: 388-391.
    • (1997) J Refract Surg , vol.13 , pp. 388-391
    • Holladay, J.T.1
  • 20
    • 0032907908 scopus 로고    scopus 로고
    • Evaluation of corneal flap dimensions and cut quality using a manually guided microkeratome
    • Behrens A, Seitz B, Langenbucher A, Kus MM, Rummelt C, Kuchle M. Evaluation of corneal flap dimensions and cut quality using a manually guided microkeratome. J Refract Surg 1999; 15: 118-123.
    • (1999) J Refract Surg , vol.15 , pp. 118-123
    • Behrens, A.1    Seitz, B.2    Langenbucher, A.3    Kus, M.M.4    Rummelt, C.5    Kuchle, M.6
  • 21
    • 0033959899 scopus 로고    scopus 로고
    • Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome
    • Behrens A, Seitz B, Langenbucher A, Kus MM, Rummelt C, Kuchle M. Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome. J Refract Surg 2000; 16: 83-89.
    • (2000) J Refract Surg , vol.16 , pp. 83-89
    • Behrens, A.1    Seitz, B.2    Langenbucher, A.3    Kus, M.M.4    Rummelt, C.5    Kuchle, M.6
  • 22
    • 0033659218 scopus 로고    scopus 로고
    • The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis
    • Durairaj VD, Balentine J, Kouyoumdjian G, Tooze JA, Young D, Spivack L et al. The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis. Ophthalmology 2000; 107: 2140-2143.
    • (2000) Ophthalmology , vol.107 , pp. 2140-2143
    • Durairaj, V.D.1    Balentine, J.2    Kouyoumdjian, G.3    Tooze, J.A.4    Young, D.5    Spivack, L.6
  • 23
    • 0034038860 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism
    • Maldonado MJ, Ruiz-Oblitas L, Munuera JM, Aliseda D, Garcia-Layana A, Moreno-Montanes J. Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism. Ophthalmology 2000; 107: 81-87.
    • (2000) Ophthalmology , vol.107 , pp. 81-87
    • Maldonado, M.J.1    Ruiz-Oblitas, L.2    Munuera, J.M.3    Aliseda, D.4    Garcia-Layana, A.5    Moreno-Montanes, J.6
  • 27
    • 0031790753 scopus 로고    scopus 로고
    • Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases
    • Gimbel HV, Penno EE, van Westenbrugge JA, Ferensowicz M, Furlong MT. Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases. Ophthalmology 1998; 105: 1839-1847.
    • (1998) Ophthalmology , vol.105 , pp. 1839-1847
    • Gimbel, H.V.1    Penno, E.E.2    van Westenbrugge, J.A.3    Ferensowicz, M.4    Furlong, M.T.5
  • 28
    • 0042939765 scopus 로고    scopus 로고
    • Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusis
    • Kim YH, Choi JS, Chun HJ, Joo CK. Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusis. J Cataract Refract Surg 1999; 25: 1448-1455.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1448-1455
    • Kim, Y.H.1    Choi, J.S.2    Chun, H.J.3    Joo, C.K.4
  • 29
    • 0034978397 scopus 로고    scopus 로고
    • Direct measurement of microkeratome gap width by electron microscopy
    • Liu KY, Lam DS. Direct measurement of microkeratome gap width by electron microscopy. J Cataract Refract Surg 2001; 27: 924-927.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 924-927
    • Liu, K.Y.1    Lam, D.S.2
  • 31
    • 0035020019 scopus 로고    scopus 로고
    • Complications of laser in situ keratomileusis: Etiology, prevention, and treatment
    • Ambrosio Jr R, Wilson SE. Complications of laser in situ keratomileusis: etiology, prevention, and treatment. J Refract Surg 2001; 17: 350-379.
    • (2001) J Refract Surg , vol.17 , pp. 350-379
    • Ambrosio Jr., R.1    Wilson, S.E.2
  • 32
    • 0031943243 scopus 로고    scopus 로고
    • Results and complications of laser in situ keratomileusis by experienced surgeons
    • Davidorf JM, Zaldivar R, Oscherow S. Results and complications of laser in situ keratomileusis by experienced surgeons. J Refract Surg 1998; 14: 114-122.
    • (1998) J Refract Surg , vol.14 , pp. 114-122
    • Davidorf, J.M.1    Zaldivar, R.2    Oscherow, S.3
  • 33
    • 0036859729 scopus 로고    scopus 로고
    • Effect of microkeratome suction duration on corneal flap thickness and incision angle
    • Seo KY, Wan XH, Jang JW, Lee JB, Kim MJ, Kim EK. Effect of microkeratome suction duration on corneal flap thickness and incision angle. J Refract Surg 2002; 18: 715-719.
    • (2002) J Refract Surg , vol.18 , pp. 715-719
    • Seo, K.Y.1    Wan, X.H.2    Jang, J.W.3    Lee, J.B.4    Kim, M.J.5    Kim, E.K.6
  • 35
    • 0030050230 scopus 로고    scopus 로고
    • Cutting the cornea with a waterjet keratome
    • Lipshitz I, Bass R, Loewenstein A. Cutting the cornea with a waterjet keratome. J Refract Surg 1996; 12: 184-186.
    • (1996) J Refract Surg , vol.12 , pp. 184-186
    • Lipshitz, I.1    Bass, R.2    Loewenstein, A.3
  • 38
    • 0037239362 scopus 로고    scopus 로고
    • Femtosecond laser flap creation for laser in situ keratomileusis: Six-month follow-up of initial US clinical series
    • Nordan LT, Slade SG, Baker RN, Suarez C, Juhasz T, Kurtz R. Femtosecond laser flap creation for laser in situ keratomileusis: Six-month follow-up of initial US clinical series. J Refract Surg 2003; 19: 8-14.
    • (2003) J Refract Surg , vol.19 , pp. 8-14
    • Nordan, L.T.1    Slade, S.G.2    Baker, R.N.3    Suarez, C.4    Juhasz, T.5    Kurtz, R.6
  • 39
    • 13544271252 scopus 로고    scopus 로고
    • Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis
    • Kezirian GM, Stonecipher KG. Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis. J Cataract Refract Surg 2004; 30: 804-811.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 804-811
    • Kezirian, G.M.1    Stonecipher, K.G.2
  • 41
    • 0033866097 scopus 로고    scopus 로고
    • Iatrogenic keratectasia after laser in situ keratomileusis for less than -4.0 to -7.0 diopters of myopia
    • Amoils SP, Deist MB, Gous P, Amoils PM. Iatrogenic keratectasia after laser in situ keratomileusis for less than -4.0 to -7.0 diopters of myopia. J Cataract Refract Surg 2000; 26: 967-977.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 967-977
    • Amoils, S.P.1    Deist, M.B.2    Gous, P.3    Amoils, P.M.4
  • 44
    • 0033497421 scopus 로고    scopus 로고
    • Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness
    • Wang Z, Chen J, Yang B. Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness. Ophthalmology 1999; 106: 406-409.
    • (1999) Ophthalmology , vol.106 , pp. 406-409
    • Wang, Z.1    Chen, J.2    Yang, B.3
  • 45
    • 0032805632 scopus 로고    scopus 로고
    • Corneal perforation during laser in situ keratomileusis
    • Joo CK, Kim TG. Corneal perforation during laser in situ keratomileusis. J Cataract Refract Surg 1999; 25: 1165-1167.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1165-1167
    • Joo, C.K.1    Kim, T.G.2
  • 46
    • 0038492789 scopus 로고    scopus 로고
    • Secondary microkeratome-induced flap interference with the pathway of the primary flap
    • Tekwani NH, Chalita MR, Krueger RR. Secondary microkeratome-induced flap interference with the pathway of the primary flap. Ophthalmology 2003; 110: 1379-1383.
    • (2003) Ophthalmology , vol.110 , pp. 1379-1383
    • Tekwani, N.H.1    Chalita, M.R.2    Krueger, R.R.3
  • 47
    • 0034803682 scopus 로고    scopus 로고
    • Evaluation of corneal stromal changes in vivo after laser in situ keratomileusis with confocal microscopy
    • Pisella PJ, Auzerie O, Bokobza Y, Debbasch C, Baudouin C. Evaluation of corneal stromal changes in vivo after laser in situ keratomileusis with confocal microscopy. Ophthalmology 2001; 108: 1744-1750.
    • (2001) Ophthalmology , vol.108 , pp. 1744-1750
    • Pisella, P.J.1    Auzerie, O.2    Bokobza, Y.3    Debbasch, C.4    Baudouin, C.5
  • 49
    • 0029780246 scopus 로고    scopus 로고
    • Differential regulation of cytokine and receptor transcript expression in human corneal and limbal fibroblasts by epidermal growth factor, transforming growth factor-alpha, platelet-derived growth factor B, and interleukin-1 beta
    • Li DQ, Tseng SC. Differential regulation of cytokine and receptor transcript expression in human corneal and limbal fibroblasts by epidermal growth factor, transforming growth factor-alpha, platelet-derived growth factor B, and interleukin-1 beta. Invest Ophthalmol Vis Sci 1996; 37: 2068-2080.
    • (1996) Invest Ophthalmol Vis Sci , vol.37 , pp. 2068-2080
    • Li, D.Q.1    Tseng, S.C.2
  • 50
    • 0028084929 scopus 로고
    • Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing
    • Reinstein DZ, Silverman RH, Rondeau MJ, Coleman DJ. Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing. Ophthalmology 1994; 101: 140-146.
    • (1994) Ophthalmology , vol.101 , pp. 140-146
    • Reinstein, D.Z.1    Silverman, R.H.2    Rondeau, M.J.3    Coleman, D.J.4
  • 53
    • 0036108896 scopus 로고    scopus 로고
    • Corneal flap thickness and tissue laser ablation in myopic LASIK
    • Maldonado MJ, Juberias JR, Rodriguez-Conde R. Corneal flap thickness and tissue laser ablation in myopic LASIK. Ophthalmology 2002; 109: 1042-1043.
    • (2002) Ophthalmology , vol.109 , pp. 1042-1043
    • Maldonado, M.J.1    Juberias, J.R.2    Rodriguez-Conde, R.3
  • 54
    • 0035514178 scopus 로고    scopus 로고
    • Microkeratome accuracy in LASIK
    • Lam DS, Rao SK, Liu KY. Microkeratome accuracy in LASIK. Ophthalmology 2001; 108: 1930-1932.
    • (2001) Ophthalmology , vol.108 , pp. 1930-1932
    • Lam, D.S.1    Rao, S.K.2    Liu, K.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.