메뉴 건너뛰기




Volumn 29, Issue 3, 2004, Pages 168-170

Reversed carotid filter for the prevention of distal emboli during an iliac recanalization;Filtre carotidien inversé pour la protection des embolies distales lors d'une recanalisation iliaque

Author keywords

Angioplasty; Filter; Iliac artery; Occlusion; Stenting

Indexed keywords

ANGIOPLASTY; CAROTID ARTERY; CONFERENCE PAPER; EMBOLISM; FEMORAL ARTERY; FIBRINOLYSIS; FILTER; ILIAC ARTERY; RECANALIZATION; STENT;

EID: 3142755056     PISSN: 03980499     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0398-0499(04)96741-8     Document Type: Conference Paper
Times cited : (2)

References (10)
  • 1
    • 0030716518 scopus 로고    scopus 로고
    • Treatment of chronic iliac artery occlusions with guide wire recanalization and primary stent placement
    • REYES R, MAYNAR M, LOPERA J, et al. Treatment of chronic iliac artery occlusions with guide wire recanalization and primary stent placement. J Vasc Interv Radiol, 1997; 8: 1049-55.
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 1049-1055
    • Reyes, R.1    Maynar, M.2    Lopera, J.3
  • 2
    • 0036207641 scopus 로고    scopus 로고
    • Long-term results of stenting for chronic iliac artery occlusion
    • UHER P, NYMAN U, LINDH M, et al. Long-term results of stenting for chronic iliac artery occlusion. J Endovasc Ther, 2002; 9: 67-75.
    • (2002) J Endovasc Ther , vol.9 , pp. 67-75
    • Uher, P.1    Nyman, U.2    Lindh, M.3
  • 3
    • 0033374743 scopus 로고    scopus 로고
    • Long-term results after recanalisation of chronic iliac artery occlusions by combined catheter therapy without stent placement
    • LEU AJ, SCHNEIDER E, CANOVA CR, et al. Long-term results after recanalisation of chronic iliac artery occlusions by combined catheter therapy without stent placement. Eur J Vasc Endovasc Surg, 1999; 18: 499-505.
    • (1999) Eur J Vasc Endovasc Surg , vol.18 , pp. 499-505
    • Leu, A.J.1    Schneider, E.2    Canova, C.R.3
  • 4
    • 0031752120 scopus 로고    scopus 로고
    • Percutaneous endoluminal treatment of iliac occlusions: Long-term follow-up in 105 patients
    • HENRY M, AMOR M, ETHEVENOT G, et al. Percutaneous endoluminal treatment of iliac occlusions: long-term follow-up in 105 patients. J Endovasc Surg, 1998; 5: 228-35.
    • (1998) J Endovasc Surg , vol.5 , pp. 228-235
    • Henry, M.1    Amor, M.2    Ethevenot, G.3
  • 5
    • 0028850382 scopus 로고
    • Late reobstruction in iliac arterial stents: Percutaneous treatment
    • VORWERK D, GUENTHER RW, SCHURMANN K, et al. Late reobstruction in iliac arterial stents: percutaneous treatment. Radiology, 1995; 197: 479-83.
    • (1995) Radiology , vol.197 , pp. 479-483
    • Vorwerk, D.1    Guenther, R.W.2    Schurmann, K.3
  • 6
    • 0036729129 scopus 로고    scopus 로고
    • Predictors of long-term results after treatment of iliac artery obliteration by transluminal angioplasty and stent deployment
    • FUNOVICS MA, LACKNER B, CEJNA M, et al. Predictors of long-term results after treatment of iliac artery obliteration by transluminal angioplasty and stent deployment. Cardiovasc Intervent Radiol, 2002; 25: 397-402.
    • (2002) Cardiovasc Intervent Radiol , vol.25 , pp. 397-402
    • Funovics, M.A.1    Lackner, B.2    Cejna, M.3
  • 7
    • 0031710069 scopus 로고    scopus 로고
    • A balloon protection sheath to prevent peripheral embolization during aortoiliac endovascular procedures
    • REEKERS JA. A balloon protection sheath to prevent peripheral embolization during aortoiliac endovascular procedures. Cardiovasc Intervent Radiol, 1998; 21: 431-3.
    • (1998) Cardiovasc Intervent Radiol , vol.21 , pp. 431-433
    • Reekers, J.A.1
  • 8
    • 0025912620 scopus 로고
    • Minibasket for percutaneous embolectomy and filter protection against distal embolization: Technical note
    • GUNTHER RW, VORWERK D. Minibasket for percutaneous embolectomy and filter protection against distal embolization: technical note. Cardiovasc Intervent Radiol, 1991; 14: 195-8.
    • (1991) Cardiovasc Intervent Radiol , vol.14 , pp. 195-198
    • Gunther, R.W.1    Vorwerk, D.2
  • 9
    • 0141706911 scopus 로고    scopus 로고
    • Frequent embolization in peripheral angioplasty: Detection with an embolism protection device (angioguard) and electron microscopy
    • KONIG CW, PUSICH B, TEPE G, et al. Frequent Embolization in Peripheral Angioplasty: Detection with an Embolism Protection Device (AngioGuard) and Electron Microscopy. Cardiovasc Intervent Radiol, 2003; 26: 334-9.
    • (2003) Cardiovasc Intervent Radiol , vol.26 , pp. 334-339
    • Konig, C.W.1    Pusich, B.2    Tepe, G.3
  • 10
    • 0038814104 scopus 로고    scopus 로고
    • Comparison of various cerebral protection devices used for carotid artery stent placement: An in vitro experiment
    • MULLER-HULSBECK S, JAHNKE T, LIESS C, et al. Comparison of various cerebral protection devices used for carotid artery stent placement: an in vitro experiment. J Vasc Interv Radiol, 2003; 14: 613-20.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 613-620
    • Muller-Hulsbeck, S.1    Jahnke, T.2    Liess, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.