Volumn 107, Issue 1, 2004, Pages 105-110

Heart rate increment: An electrocardiological approach for the early detection of obstructive sleep apnoea/hypopnoea syndrome

Author keywords

Autonomous nervous system; ECG Holter monitoring; Heart rate variability; Obstructive sleep apnoea hypopnoea syndrome

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HEART RATE; HOLTER MONITORING; HUMAN; MALE; POLYSOMNOGRAPHY; PREDICTION; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; RESPIRATORY FAILURE; SENSITIVITY AND SPECIFICITY; SLEEP APNEA SYNDROME;

EID: 3142708576     PISSN: 01435221     EISSN: None     Source Type: Journal    
DOI: 10.1042/CS20040036     Document Type: Article
Times cited : (29)

References (26)
  • 1
    • 0027462562 scopus 로고
    • The occurrence of sleep-disordered breathing among middle-aged adults
    • Young, T., Palta, M., Dempsey, J., Skatrud, J., Wever, S. and Safwan, B. (1993) The occurrence of sleep-disordered breathing among middle-aged adults. N. Engl. J. Med. 328, 1230-1235
    • (1993) N. Engl. J. Med. , vol.328 , pp. 1230-1235
    • Young, T.1    Palta, M.2    Dempsey, J.3    Skatrud, J.4    Wever, S.5    Safwan, B.6
  • 3
    • 0024239442 scopus 로고
    • Long-term outcome for obstructive sleep apnea syndrome patients: Mortality
    • Partinen, M., Jamieson, A. and Guilleminault C. (1988) Long-term outcome for obstructive sleep apnea syndrome patients: mortality. Chest 94, 1200-1204
    • (1988) Chest , vol.94 , pp. 1200-1204
    • Partinen, M.1    Jamieson, A.2    Guilleminault, C.3
  • 4
    • 0030889813 scopus 로고    scopus 로고
    • Snoring and breathing pauses during sleep: Telephone interview survey of a United Kingdom population sample
    • Óhayon, M. M., Guilleminault, C., Priest, R. G. and Caulet, M. (1997) Snoring and breathing pauses during sleep: telephone interview survey of a United Kingdom population sample. Br. Med. J. 314, 860-865
    • (1997) Br. Med. J. , vol.314 , pp. 860-865
    • Óhayon, M.M.1    Guilleminault, C.2    Priest, R.G.3    Caulet, M.4
  • 5
    • 0021288422 scopus 로고
    • Cyclical variation of the heart rate in sleep apnoea syndrome
    • Guilleminault, C., Connoly, S., Winkle, R., Melvin, K. and Tilkian, A. (1984) Cyclical variation of the heart rate in sleep apnoea syndrome. Lancet 21, 126-131
    • (1984) Lancet , vol.21 , pp. 126-131
    • Guilleminault, C.1    Connoly, S.2    Winkle, R.3    Melvin, K.4    Tilkian, A.5
  • 6
    • 0033613141 scopus 로고    scopus 로고
    • Screening of obstructive sleep apnea syndrome by heart rate variability analysis
    • Roche, F., Gaspoz, J. M., Court-Fortune, I. et al. (1999) Screening of obstructive sleep apnea syndrome by heart rate variability analysis. Circulation 100, 1411-1415
    • (1999) Circulation , vol.100 , pp. 1411-1415
    • Roche, F.1    Gaspoz, J.M.2    Court-Fortune, I.3
  • 7
    • 0024369848 scopus 로고
    • Frequency characteristics of the heart rate variability produced by Cheyne-Stokes respiration during 24-hour ambulatory electrocardiographic monitoring
    • Ichimaru, Y. and Yanaga, T. (1989) Frequency characteristics of the heart rate variability produced by Cheyne-Stokes respiration during 24-hour ambulatory electrocardiographic monitoring. IEEE Comput. Biomed. Res. 22, 225-233
    • (1989) IEEE Comput. Biomed. Res. , vol.22 , pp. 225-233
    • Ichimaru, Y.1    Yanaga, T.2
  • 8
    • 0030036922 scopus 로고    scopus 로고
    • Augmented very low frequency component of heart rate variability during obstructive sleep apnea
    • Shiomi, T., Guilleminault, C., Sasanabe, R., Hirota, I., Maekawa, M. and Koboyashi, T. (1996) Augmented very low frequency component of heart rate variability during obstructive sleep apnea. Sleep 19, 370-377
    • (1996) Sleep , vol.19 , pp. 370-377
    • Shiomi, T.1    Guilleminault, C.2    Sasanabe, R.3    Hirota, I.4    Maekawa, M.5    Koboyashi, T.6
  • 9
    • 0036693599 scopus 로고    scopus 로고
    • Cardiac interbeat interval increment for the identification of obstructive sleep apnea
    • Roche, F., Duverney, D., Court-Fortune, I. et al. (2002) Cardiac interbeat interval increment for the identification of obstructive sleep apnea. Pacing Clin. Electrophysiol. 25, 1192-1199
    • (2002) Pacing Clin. Electrophysiol. , vol.25 , pp. 1192-1199
    • Roche, F.1    Duverney, D.2    Court-Fortune, I.3
  • 10
    • 0033178851 scopus 로고    scopus 로고
    • Sleep-related breathing disorders in adults: Recommendation for syndrome definition and measurement techniques in clinical research
    • American Academy of Sleep Medecine (1999) Sleep-related breathing disorders in adults: recommendation for syndrome definition and measurement techniques in clinical research. Sleep 22, 667-689
    • (1999) Sleep , vol.22 , pp. 667-689
  • 13
    • 0020083498 scopus 로고
    • The meaning and use of the area under receiver operating characteristic (ROC) curve
    • Hanley, J. A. and McNeil, B. J. (1982) The meaning and use of the area under receiver operating characteristic (ROC) curve. Radiology 143, 29-36
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 14
    • 0034480920 scopus 로고    scopus 로고
    • Screening for obstructive sleep apnoea based on the electrocardiogram: The computers in cardiology challenge
    • Raymond, B. Cayton, R. M. Bates, R. A. and Chappell, M. J. (2000) Screening for obstructive sleep apnoea based on the electrocardiogram: the computers in cardiology challenge. Comput. Cardiol. 27, 267-270
    • (2000) Comput. Cardiol. , vol.27 , pp. 267-270
    • Raymond, B.1    Cayton, R.M.2    Bates, R.A.3    Chappell, M.J.4
  • 16
    • 0030020959 scopus 로고    scopus 로고
    • Accuracy of oximetry for detection of respiratory disturbances in sleep apnea syndrome
    • Lévy, P., Pépin, J. L., Deschaux-Blanc, C., Paramelle, B. and Brambilla, C. (1996) Accuracy of oximetry for detection of respiratory disturbances in sleep apnea syndrome. Chest 109, 395-399
    • (1996) Chest , vol.109 , pp. 395-399
    • Lévy, P.1    Pépin, J.L.2    Deschaux-Blanc, C.3    Paramelle, B.4    Brambilla, C.5
  • 17
    • 0027373702 scopus 로고
    • Utility of nocturnal home oxymetry for case finding in patients with suspected sleep apnea hypopnea syndrome
    • Series, F., Marc, I., Cormier, Y. and La Forge, J. (1993) Utility of nocturnal home oxymetry for case finding in patients with suspected sleep apnea hypopnea syndrome. Ann. Intern. Med. 119, 449-453
    • (1993) Ann. Intern. Med. , vol.119 , pp. 449-453
    • Series, F.1    Marc, I.2    Cormier, Y.3    La Forge, J.4
  • 18
    • 0034827710 scopus 로고    scopus 로고
    • Overnight pulse oximetry for sleep-disordered breathing in adults. A review
    • Netzer, N., Eliasson, A. H., Netzer, C. and Kristo, D. A. (2001) Overnight pulse oximetry for sleep-disordered breathing in adults. A review. Chest 120, 625-633
    • (2001) Chest , vol.120 , pp. 625-633
    • Netzer, N.1    Eliasson, A.H.2    Netzer, C.3    Kristo, D.A.4
  • 19
    • 0030497894 scopus 로고    scopus 로고
    • New approaches to monitoring sleep-related breathing disorders
    • Stradling, J. R., Davies, R. J. O. and Pitson, D. J. (1996) New approaches to monitoring sleep-related breathing disorders. Sleep 19, S77-S84
    • (1996) Sleep , vol.19
    • Stradling, J.R.1    Davies, R.J.O.2    Pitson, D.J.3
  • 20
    • 0031710038 scopus 로고    scopus 로고
    • Value of beat-to-beat pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome
    • Pitson, D. J. and Stradling, J. R. (1998) Value of beat-to-beat pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome. Eur. Respir. J. 12, 685-692
    • (1998) Eur. Respir. J. , vol.12 , pp. 685-692
    • Pitson, D.J.1    Stradling, J.R.2
  • 21
    • 0031970652 scopus 로고    scopus 로고
    • Autonomic markers of arousal during sleep in patients undergoing investigation for obstructive sleep apnoea, their relationship to EEG arousals, respiratory events and subjective sleepiness
    • Pitson, D. J. and Stradling, J. R. (1998) Autonomic markers of arousal during sleep in patients undergoing investigation for obstructive sleep apnoea, their relationship to EEG arousals, respiratory events and subjective sleepiness. J. Sleep. Res. 7, 53-59
    • (1998) J. Sleep. Res. , vol.7 , pp. 53-59
    • Pitson, D.J.1    Stradling, J.R.2
  • 22
    • 0033541019 scopus 로고    scopus 로고
    • EEG and cardiac activation during periodic leg movements in sleep: Support for a hierarchy of arousal responses
    • Sforza, E., Nicolas, A., Lavigne, G., Gosselin, A., Petit, D. and Montplaisir, J. (1999) EEG and cardiac activation during periodic leg movements in sleep: support for a hierarchy of arousal responses. Neurology 52, 786-791
    • (1999) Neurology , vol.52 , pp. 786-791
    • Sforza, E.1    Nicolas, A.2    Lavigne, G.3    Gosselin, A.4    Petit, D.5    Montplaisir, J.6
  • 23
    • 0742324112 scopus 로고    scopus 로고
    • Clinical significance of pulse rate rise during sleep as a screening marker for assessment of sleep fragmentation in sleep-disordered breathing
    • Adachi, H., Mikami, A., Kumano-go, T. et al. (2003) Clinical significance of pulse rate rise during sleep as a screening marker for assessment of sleep fragmentation in sleep-disordered breathing. Sleep Med. 4, 537-542
    • (2003) Sleep Med. , vol.4 , pp. 537-542
    • Adachi, H.1    Mikami, A.2    Kumano-go, T.3
  • 24
    • 0345040792 scopus 로고    scopus 로고
    • Differentiating obstructive and central sleep respiratory events through pulse transit time
    • Argod, J., Pépin, J. L. and Lévy, P. (1998) Differentiating obstructive and central sleep respiratory events through pulse transit time. Am. J. Respir. Crit. Care Med. 158, 1778-1783
    • (1998) Am. J. Respir. Crit. Care Med. , vol.158 , pp. 1778-1783
    • Argod, J.1    Pépin, J.L.2    Lévy, P.3
  • 25
    • 0036652620 scopus 로고    scopus 로고
    • Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings
    • Penzel, T., McNames, J., de Chazal, P., Raymond, B., Murray, A. and Moody, G. (2002) Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings. Med. Biol. Eng. Comput. 40, 402-407
    • (2002) Med. Biol. Eng. Comput. , vol.40 , pp. 402-407
    • Penzel, T.1    McNames, J.2    De Chazal, P.3    Raymond, B.4    Murray, A.5    Moody, G.6
  • 26
    • 0032827473 scopus 로고    scopus 로고
    • Oximetry spectral analysis in the diagnosis of obstructive sleep apnoea
    • Zamarron, C., Romero, P. V., Rodriguez, J. R. and Gude, F. (1999) Oximetry spectral analysis in the diagnosis of obstructive sleep apnoea. Clin. Sci. 97, 467-473
    • (1999) Clin. Sci. , vol.97 , pp. 467-473
    • Zamarron, C.1    Romero, P.V.2    Rodriguez, J.R.3    Gude, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.