메뉴 건너뛰기




Volumn 38, Issue 6, 2004, Pages 356-360

Non-invasive measurement of tendon excursion with a colour Doppler imaging system: A reliability study in healthy subjects

Author keywords

Colour Doppler imaging; Hand; Healthy subjects; Tendon excursion; Test retest reliability

Indexed keywords

ADULT; ARTICLE; DIAGNOSTIC IMAGING; DOPPLER ECHOGRAPHY; FEMALE; FINGER; FLEXOR MUSCLE; FLEXOR TENDON; HAND MOVEMENT; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; RELIABILITY;

EID: 3142700566     PISSN: 02844311     EISSN: None     Source Type: Journal    
DOI: 10.1080/02844310410030613     Document Type: Article
Times cited : (12)

References (17)
  • 2
    • 3142669685 scopus 로고    scopus 로고
    • Non-invasive tendon excursion measurement with colour Doppler imaging: In vivo application of a new technique
    • Buyruk HM, (thesis). Rotterdam: Erasmus University
    • Buyruk HM, Stam HJ, Snijders CJ et al. Non-invasive tendon excursion measurement with colour Doppler imaging: in vivo application of a new technique. In: Buyruk HM, (thesis). Colour Doppler imaging: new applications in musculoskeletal system pathology. Rotterdam: Erasmus University, 1996: 1-6.
    • (1996) Colour Doppler Imaging: New Applications in Musculoskeletal System Pathology , pp. 1-6
    • Buyruk, H.M.1    Stam, H.J.2    Snijders, C.J.3
  • 3
    • 0031862645 scopus 로고    scopus 로고
    • Tendon excursion measurements with colour Doppler imaging
    • Buyruk HM, Holland WPJ, Snijders CJ et al. Tendon excursion measurements with colour Doppler imaging. J Hand Surg 1998; 23B: 350-353.
    • (1998) J Hand Surg , vol.23 B , pp. 350-353
    • Buyruk, H.M.1    Holland, W.P.J.2    Snijders, C.J.3
  • 4
    • 0030294864 scopus 로고    scopus 로고
    • Measurement of tendon excursion velocity with colour Doppler imaging: A preliminary study on flexor pollicis longus muscle
    • Cigali BS, Buyruk HM, Snijders CJ et al. Measurement of tendon excursion velocity with colour Doppler imaging: a preliminary study on flexor pollicis longus muscle. Eur J Radiol 1996; 23: 217-221.
    • (1996) Eur J Radiol , vol.23 , pp. 217-221
    • Cigali, B.S.1    Buyruk, H.M.2    Snijders, C.J.3
  • 5
    • 0019429773 scopus 로고
    • Elongation in profundus tendon repair. A clinical and radiological study
    • Ejeskar A, Irstam L. Elongation in profundus tendon repair. A clinical and radiological study. Scand J Plast Reconstr Surg 1981; 15: 61-68.
    • (1981) Scand J Plast Reconstr Surg , vol.15 , pp. 61-68
    • Ejeskar, A.1    Irstam, L.2
  • 6
    • 0022643480 scopus 로고
    • The excursion and deformation of repaired flexor tendons treated with protected early motion
    • Gelberman RH, Botte MJ, Spiegelman JJ, Akeson WH. The excursion and deformation of repaired flexor tendons treated with protected early motion. J Hand Surg 1986; 11A: 106-110.
    • (1986) J Hand Surg , vol.11 A , pp. 106-110
    • Gelberman, R.H.1    Botte, M.J.2    Spiegelman, J.J.3    Akeson, W.H.4
  • 7
    • 0025883905 scopus 로고
    • Tendon excursion and dehiscence during early controlled mobilization after flexor tendon repair in zone II: An x-ray stereophotogrammetric analysis
    • Hagberg L, Selvik G. Tendon excursion and dehiscence during early controlled mobilization after flexor tendon repair in zone II: an x-ray stereophotogrammetric analysis. J Hand Surg 1991; 16A: 669-680.
    • (1991) J Hand Surg , vol.16 A , pp. 669-680
    • Hagberg, L.1    Selvik, G.2
  • 8
    • 0032869979 scopus 로고    scopus 로고
    • Tendon displacement assessment by pulsed Doppler tissue imaging: Validation with a reciprocating string test target
    • Holland WP, Buyruk HM, Hoorn E, Stam HJ. Tendon displacement assessment by pulsed Doppler tissue imaging: validation with a reciprocating string test target. Ultrasound Med Biol 1999; 25: 1229-1239.
    • (1999) Ultrasound Med Biol , vol.25 , pp. 1229-1239
    • Holland, W.P.1    Buyruk, H.M.2    Hoorn, E.3    Stam, H.J.4
  • 10
    • 0027155544 scopus 로고
    • The application of generalizability theory to reliability assessment: An illustration using isometric force measurements
    • Roebroeck ME, Harlaar J, Lankhorst GJ. The application of generalizability theory to reliability assessment: an illustration using isometric force measurements. Phys Ther 1993; 73: 386-401.
    • (1993) Phys Ther , vol.73 , pp. 386-401
    • Roebroeck, M.E.1    Harlaar, J.2    Lankhorst, G.J.3
  • 12
    • 0026593784 scopus 로고
    • Flexor digitorum profundus tendon excursions during controlled motion after flexor tendon repair in zone II: A prospective clinical study
    • Silfverskiold KL, May EJ, Tornvall AH. Flexor digitorum profundus tendon excursions during controlled motion after flexor tendon repair in zone II: a prospective clinical study. J Hand Surg 1992; 17A: 122-131.
    • (1992) J Hand Surg , vol.17 A , pp. 122-131
    • Silfverskiold, K.L.1    May, E.J.2    Tornvall, A.H.3
  • 13
    • 0027295155 scopus 로고
    • Tendon excursions after flexor tendon repair in zone II: Results with a new controlled-motion program
    • Silfverskiold KL, May EJ, Tornvall AH. Tendon excursions after flexor tendon repair in zone II: results with a new controlled-motion program. J Hand Surg 1993; 18A: 403-410.
    • (1993) J Hand Surg , vol.18 A , pp. 403-410
    • Silfverskiold, K.L.1    May, E.J.2    Tornvall, A.H.3
  • 15
    • 0001709692 scopus 로고
    • Syndrome of the quadriga
    • Verdan C. Syndrome of the quadriga. Surg Clin North Am 1960; 40: 425.
    • (1960) Surg Clin North Am , vol.40 , pp. 425
    • Verdan, C.1
  • 16
    • 0022316884 scopus 로고
    • Flexor tendon gliding in the hand. Part I. In vivo excursions
    • Wehbe MA, Hunter JM. Flexor tendon gliding in the hand. Part I. In vivo excursions. J Hand Surg 1985; 10A: 570-574.
    • (1985) J Hand Surg , vol.10 A , pp. 570-574
    • Wehbe, M.A.1    Hunter, J.M.2
  • 17
    • 0034891639 scopus 로고    scopus 로고
    • Gliding resistance after repair of partially lacerated human flexor digitorum profundus tendon in vitro
    • Zhao C, Amadio PC, Zobitz ME, Momose T, Couvreur P, An K. Gliding resistance after repair of partially lacerated human flexor digitorum profundus tendon in vitro. Clin Biomech 2001; 16: 696-701.
    • (2001) Clin Biomech , vol.16 , pp. 696-701
    • Zhao, C.1    Amadio, P.C.2    Zobitz, M.E.3    Momose, T.4    Couvreur, P.5    An, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.