메뉴 건너뛰기




Volumn 47, Issue 2, 2004, Pages 111-114

Percutaneous transarticular atlantoaxial screw fixation using a cannulated screw system and image guidance

Author keywords

Atlantoaxial instability; Cannulated screw; Computer assisted spine surgery; Percutaneous screw application; Transarticular screw fixation

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; ATLANTOAXIAL DISLOCATION; ATLANTOAXIAL JOINT; ATLANTOOCCIPITAL JOINT; BONE SCREW; CLINICAL ARTICLE; COMPUTER ASSISTED SURGERY; DRILL; FEMALE; FOLLOW UP; FRACTURE FIXATION; HUMAN; IMAGING SYSTEM; JOINT STABILITY; KIRSCHNER WIRE; MALE; ODONTOID PROCESS FRACTURE; OUTCOMES RESEARCH; PERCUTANEOUS TRANSARTICULAR ATLANTOAXIAL SCREW FIXATION; PROSTHESIS FAILURE; RHEUMATOID ARTHRITIS; SPINE FUSION; SPINE STABILIZATION; SURGICAL TECHNIQUE;

EID: 3142678732     PISSN: 09467211     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-818449     Document Type: Article
Times cited : (32)

References (12)
  • 1
    • 0037102598 scopus 로고    scopus 로고
    • Posterior atlantoaxial fixation: Biomechanical in vitro comparison of six different techniques
    • Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ. Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine 2002; 27: 1724-1732
    • (2002) Spine , vol.27 , pp. 1724-1732
    • Richter, M.1    Schmidt, R.2    Claes, L.3    Puhl, W.4    Wilke, H.J.5
  • 2
    • 85047679729 scopus 로고    scopus 로고
    • Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures
    • Blauth M, Richter M, Lange U. Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures. Orthopäde 1999; 28: 651-661
    • (1999) Orthopäde , vol.28 , pp. 651-661
    • Blauth, M.1    Richter, M.2    Lange, U.3
  • 3
    • 0034973117 scopus 로고    scopus 로고
    • C1-C2 transarticular screw fixation: Technical aspects
    • Haid Jr RW. C1-C2 transarticular screw fixation: technical aspects. Neurosurgery 2001; 49: 71-74
    • (2001) Neurosurgery , vol.49 , pp. 71-74
    • Haid Jr., R.W.1
  • 5
    • 0034667351 scopus 로고    scopus 로고
    • Modification of C1-C2 transarticular screw fixation by image-guided surgery
    • Weidner A, Wähler M, Chiu ST, Ullrich CG. Modification of C1-C2 transarticular screw fixation by image-guided surgery. Spine 2000; 25: 2668-2674
    • (2000) Spine , vol.25 , pp. 2668-2674
    • Weidner, A.1    Wähler, M.2    Chiu, S.T.3    Ullrich, C.G.4
  • 6
    • 0034960787 scopus 로고    scopus 로고
    • A technique for frameless stereotaxy and placement of transarticular screws for atlanto-axial instability in rheumatoid arthritis
    • Wigfield C, Bolger C. A technique for frameless stereotaxy and placement of transarticular screws for atlanto-axial instability in rheumatoid arthritis. Eur Spine J 2001; 10: 264-268
    • (2001) Eur Spine J , vol.10 , pp. 264-268
    • Wigfield, C.1    Bolger, C.2
  • 7
    • 0034840830 scopus 로고    scopus 로고
    • In vivo experiences with frameless stereotactically guided screw placement in the spine - Results from 75 consecutive cases
    • Braun V, Rath SA, Antoniadis G, Richter H-P. In vivo experiences with frameless stereotactically guided screw placement in the spine - results from 75 consecutive cases. Neurosurg Rev 2001; 24: 74-79
    • (2001) Neurosurg Rev , vol.24 , pp. 74-79
    • Braun, V.1    Rath, S.A.2    Antoniadis, G.3    Richter, H.-P.4
  • 8
    • 0001908749 scopus 로고    scopus 로고
    • Computer-assisted surgery in posterior instrumentation of the cervical spine: An in-vitro feasibility study
    • Richter M, Amiot L, Neller S, Kluger P, Puhl W. Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study. Eur Spine J 2000; 9 (Suppl 1): S65-S70
    • (2000) Eur Spine J , vol.9 , Issue.SUPPL. 1
    • Richter, M.1    Amiot, L.2    Neller, S.3    Kluger, P.4    Puhl, W.5
  • 10
    • 0029589499 scopus 로고
    • Cannulated screws for odontoid screw fixation and atlantoaxial transarticular screw fixation. Technical note
    • Dickman CA, Foley KT, Sonntag VK, Smith MM. Cannulated screws for odontoid screw fixation and atlantoaxial transarticular screw fixation. Technical note. J Neurosurg 1995; 83: 1095-1100
    • (1995) J Neurosurg , vol.83 , pp. 1095-1100
    • Dickman, C.A.1    Foley, K.T.2    Sonntag, V.K.3    Smith, M.M.4
  • 11
    • 0028841276 scopus 로고
    • Modification of technique and results of atlantoaxial transfacet stabilization
    • McGuire Jr RA, Harkey HL. Modification of technique and results of atlantoaxial transfacet stabilization. Orthopedics 1995; 18: 1029-1032
    • (1995) Orthopedics , vol.18 , pp. 1029-1032
    • McGuire Jr., R.A.1    Harkey, H.L.2
  • 12
    • 0033771307 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: In-vitro comparison with two established implant systems
    • Richter M, Wilke H-J, Kluger P, Neller S, Claes L, Puhl W. Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in-vitro comparison with two established implant systems. Eur Spine J 2000; 9: 417-425
    • (2000) Eur Spine J , vol.9 , pp. 417-425
    • Richter, M.1    Wilke, H.-J.2    Kluger, P.3    Neller, S.4    Claes, L.5    Puhl, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.