메뉴 건너뛰기




Volumn , Issue , 2004, Pages 335-343

Spectrophotometry - Derivative Techniques

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBANCE SPECTRUM; DERIVATIVE SPECTRA; DERIVATIVE SPECTROSCOPY; DERIVATIVE TECHNIQUE; FIRST-ORDER DERIVATIVE; HIGH ORDER DERIVATIVES; MATHEMATICAL METHOD; QUALITATIVE AND QUANTITATIVE ANALYSIS; SPECTRAL FEATURE; TRANSMISSION SPECTRUMS;

EID: 3142671608     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B0-12-369397-7/00717-2     Document Type: Chapter
Times cited : (3)

References (14)
  • 1
    • 0000775693 scopus 로고
    • Recent developments in derivative ultraviolet/visible absorption spectrophotometry
    • Bosch O.C., Sanchez R.F., Cano P.J. Recent developments in derivative ultraviolet/visible absorption spectrophotometry. Talanta 1995, 42:1195-1214.
    • (1995) Talanta , vol.42 , pp. 1195-1214
    • Bosch, O.C.1    Sanchez, R.F.2    Cano, P.J.3
  • 2
    • 0034229591 scopus 로고    scopus 로고
    • Derivative preprocessing and optimal correction for baseline drift in multivariate calibration
    • Brown C., Vega-Montoto L., Wentzell P. Derivative preprocessing and optimal correction for baseline drift in multivariate calibration. Applied Spectroscopy 2000, 54:1055-1068.
    • (2000) Applied Spectroscopy , vol.54 , pp. 1055-1068
    • Brown, C.1    Vega-Montoto, L.2    Wentzell, P.3
  • 3
    • 0022291105 scopus 로고
    • Quantitative analysis by derivative electronic spectroscopy
    • Dixit L., Ram S. Quantitative analysis by derivative electronic spectroscopy. Applied Spectroscopy Review 1985, 21:311-418.
    • (1985) Applied Spectroscopy Review , vol.21 , pp. 311-418
    • Dixit, L.1    Ram, S.2
  • 4
    • 0020720786 scopus 로고
    • Biomedical applications of derivative spectroscopy
    • Fell A. Biomedical applications of derivative spectroscopy. Trends in Analytical Chemistry 1983, 2(3):63-66.
    • (1983) Trends in Analytical Chemistry , vol.2 , Issue.3 , pp. 63-66
    • Fell, A.1
  • 6
    • 0017942420 scopus 로고
    • Improving analysis from second-derivative UV-absorption spectrometry
    • Hawthorne A., Thorngate J. Improving analysis from second-derivative UV-absorption spectrometry. Applied Optics 1978, 17:724-729.
    • (1978) Applied Optics , vol.17 , pp. 724-729
    • Hawthorne, A.1    Thorngate, J.2
  • 8
    • 0019621375 scopus 로고
    • Signal-to-noise in higher order derivative spectrometry
    • O'Haver T.C., Begley T. Signal-to-noise in higher order derivative spectrometry. Analytical Chemistry 1981, 53:1876-1878.
    • (1981) Analytical Chemistry , vol.53 , pp. 1876-1878
    • O'Haver, T.C.1    Begley, T.2
  • 9
    • 0032679751 scopus 로고    scopus 로고
    • Dynamic derivative UV-spectroscopy for combustion monitoring
    • Sassenscheid K., Klocke U., Marb C., et al. Dynamic derivative UV-spectroscopy for combustion monitoring. Proceedings of SPIE 1998, 3535:204-214.
    • (1998) Proceedings of SPIE , vol.3535 , pp. 204-214
    • Sassenscheid, K.1    Klocke, U.2    Marb, C.3
  • 10
    • 0032643645 scopus 로고    scopus 로고
    • Enhanced selectivity and sensitivity in UV-analysis of volatile organic compounds
    • Sassenscheid K., Klocke U., Marb C., et al. Enhanced selectivity and sensitivity in UV-analysis of volatile organic compounds. Proceedings of SPIE 1998, 3533:222-233.
    • (1998) Proceedings of SPIE , vol.3533 , pp. 222-233
    • Sassenscheid, K.1    Klocke, U.2    Marb, C.3
  • 11
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • Savitzky A., Golay M. Smoothing and differentiation of data by simplified least squares procedures. Analytical Chemistry 1964, 36:1627-1639.
    • (1964) Analytical Chemistry , vol.36 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.2
  • 12
    • 0345591924 scopus 로고
    • Smoothing and differentiation of data by simplified least square procedure
    • Steiner J., Termonia Y., Deltour J. Smoothing and differentiation of data by simplified least square procedure. Analytical Chemistry 1972, 44:1906-1909.
    • (1972) Analytical Chemistry , vol.44 , pp. 1906-1909
    • Steiner, J.1    Termonia, Y.2    Deltour, J.3
  • 13
    • 0033318165 scopus 로고    scopus 로고
    • Optical UV derivative-spectroscopy for monitoring gaseous emissions
    • Vogt F., Klocke U., Rebstock K., et al. Optical UV derivative-spectroscopy for monitoring gaseous emissions. Applied Spectroscopy 1999, 53:1352-1360.
    • (1999) Applied Spectroscopy , vol.53 , pp. 1352-1360
    • Vogt, F.1    Klocke, U.2    Rebstock, K.3
  • 14
    • 0014817653 scopus 로고
    • The derivative spectrometer
    • Williams D., Hager R. The derivative spectrometer. Applied Optics 1970, 9:1597-1605.
    • (1970) Applied Optics , vol.9 , pp. 1597-1605
    • Williams, D.1    Hager, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.