메뉴 건너뛰기




Volumn 18, Issue 3, 2004, Pages 251-256

Optimum threshold setting for a positron-sensitive probe with background rejection capability

Author keywords

Background; Positron; Probe; Threshold

Indexed keywords

BISMUTH GERMANATE; PLASTIC; UNCLASSIFIED DRUG;

EID: 3142628180     PISSN: 09147187     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02985007     Document Type: Article
Times cited : (9)

References (12)
  • 2
    • 0033058305 scopus 로고    scopus 로고
    • A method to evaluate intra-operative gamma probes for sentinel lymph node localization
    • Britten AJ. A method to evaluate intra-operative gamma probes for sentinel lymph node localization. Eur J Nucl Med 1999; 26 (2): 76-83.
    • (1999) Eur J Nucl Med , vol.26 , Issue.2 , pp. 76-83
    • Britten, A.J.1
  • 3
    • 0035746433 scopus 로고    scopus 로고
    • Application of an F-18-fluorodeoxyglucose-sensitive probe for the intraoperative detection of malignancy
    • Essner R, Hsueh EC, Haigh PI, Glass EC, Huynh Y, Daghighian F. Application of an F-18-fluorodeoxyglucose-sensitive probe for the intraoperative detection of malignancy. J Surg Res 2001; 96: 120-126.
    • (2001) J Surg Res , vol.96 , pp. 120-126
    • Essner, R.1    Hsueh, E.C.2    Haigh, P.I.3    Glass, E.C.4    Huynh, Y.5    Daghighian, F.6
  • 4
    • 0035542624 scopus 로고    scopus 로고
    • F-18-labeled fluorodeoxyglucose positron emission tomography-guided surgery for recurrent colorectal cancer: A feasibility study
    • Zervos EE, Desai DC, Depalatis LR, Soble D, Martin EW. F-18-labeled fluorodeoxyglucose positron emission tomography-guided surgery for recurrent colorectal cancer: a feasibility study. J Surg Res 2001; 97: 9-13.
    • (2001) J Surg Res , vol.97 , pp. 9-13
    • Zervos, E.E.1    Desai, D.C.2    Depalatis, L.R.3    Soble, D.4    Martin, E.W.5
  • 5
    • 0012788732 scopus 로고    scopus 로고
    • Correlative whole-body FDG-PET and intraoperative gamma detection of FDG distribution in colorectal cancer
    • Desai DC, Arnold M, Saha S, Hinkle G, Soble D, Fry J, et al. Correlative whole-body FDG-PET and intraoperative gamma detection of FDG distribution in colorectal cancer. Clinical Positron Imaging 2000; 3 (5): 189-194.
    • (2000) Clinical Positron Imaging , vol.3 , Issue.5 , pp. 189-194
    • Desai, D.C.1    Arnold, M.2    Saha, S.3    Hinkle, G.4    Soble, D.5    Fry, J.6
  • 6
    • 0034952536 scopus 로고    scopus 로고
    • Detection of atherosclerosis using a novel positron-sensitive probe and 18-fluorodeoxyglucose (FDG)
    • Lederman RJ, Raylman RR, Fisher SJ, Kison PV, San H, Nabel EG, et al. Detection of atherosclerosis using a novel positron-sensitive probe and 18-fluorodeoxyglucose (FDG). Nucl Med Commun 2001; 22 (7): 747-753.
    • (2001) Nucl Med Commun , vol.22 , Issue.7 , pp. 747-753
    • Lederman, R.J.1    Raylman, R.R.2    Fisher, S.J.3    Kison, P.V.4    San, H.5    Nabel, E.G.6
  • 7
    • 0027955503 scopus 로고
    • Intraoperative beta probe: A device for detecting tissue labeled with positron or electron emitting isotopes during surgery
    • Daghighian F, Mazziotta JC, Hoffman EJ, Shenderov P, Eshaghian B, Siegel S, et al. Intraoperative beta probe: a device for detecting tissue labeled with positron or electron emitting isotopes during surgery. Med Phys 1994; 21 (1): 153-157.
    • (1994) Med Phys , vol.21 , Issue.1 , pp. 153-157
    • Daghighian, F.1    Mazziotta, J.C.2    Hoffman, E.J.3    Shenderov, P.4    Eshaghian, B.5    Siegel, S.6
  • 9
    • 0000703245 scopus 로고    scopus 로고
    • Annihilation gamma ray background characterization and rejection for a small beta camera used for tumor localization during surgery
    • Levin CS, Tornai MP, MacDonald LR, et al. Annihilation gamma ray background characterization and rejection for a small beta camera used for tumor localization during surgery. IEEE Trans Nucl Sci 1997; 44: 1120-1126.
    • (1997) IEEE Trans Nucl Sci , vol.44 , pp. 1120-1126
    • Levin, C.S.1    Tornai, M.P.2    MacDonald, L.R.3
  • 10
    • 0032095004 scopus 로고    scopus 로고
    • A miniature phoswich detector for gamma-ray localization and beta imaging
    • Tornai MP, Levin CS, MacDonald LR, et al. A miniature phoswich detector for gamma-ray localization and beta imaging. IEEE Trans Nucl Sci 1998; 45: 1166-1173.
    • (1998) IEEE Trans Nucl Sci , vol.45 , pp. 1166-1173
    • Tornai, M.P.1    Levin, C.S.2    MacDonald, L.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.