-
1
-
-
0019783774
-
Effect of the hemodialysis prescription on patient morbidity: Report from the National Cooperative Dialysis Study
-
Lawarie EG, Laird NM, Parker TF, Sargent JA. Effect of the hemodialysis prescription on patient morbidity: report from the National Cooperative Dialysis Study. N Engl J Med 1981;305: 1176-81.
-
(1981)
N Engl J Med
, vol.305
, pp. 1176-1181
-
-
Lawarie, E.G.1
Laird, N.M.2
Parker, T.F.3
Sargent, J.A.4
-
2
-
-
0027688501
-
Second generation logarithmic estimates of single pool variable volume Kt/V: An analysis of error
-
Daugirdas JT. Second generation logarithmic estimates of single pool variable volume Kt/V: an analysis of error. J Am Soc Nephrol 1993;4:1205-13.
-
(1993)
J Am Soc Nephrol
, vol.4
, pp. 1205-1213
-
-
Daugirdas, J.T.1
-
3
-
-
84979445422
-
Pitfalls in quantifying hemodialysis
-
Depner TA. Pitfalls in quantifying hemodialysis. Semin Dial 1993;6:127-33.
-
(1993)
Semin Dial
, vol.6
, pp. 127-133
-
-
Depner, T.A.1
-
4
-
-
0030964205
-
A simple and accurate method to determine equilibrated post-dialysis urea concentration
-
Bernard B, Bosc J-Y, Leblanc M, Garred L, Vaussenat F, Bonardet A, et al. A simple and accurate method to determine equilibrated post-dialysis urea concentration. Kidney Int 1997;51:2000-5.
-
(1997)
Kidney Int
, vol.51
, pp. 2000-2005
-
-
Bernard, B.1
Bosc, J.-Y.2
Leblanc, M.3
Garred, L.4
Vaussenat, F.5
Bonardet, A.6
-
5
-
-
0002473177
-
Kinetic modeling in hemodialysis
-
Nissenson AR, Fine RN, Gentile DE, editors. East Norwalk: Appleton and Lange
-
Gotch FA. Kinetic modeling in hemodialysis. In: Nissenson AR, Fine RN, Gentile DE, editors. Clinical dialysis. Third Ed. East Norwalk: Appleton and Lange; 1995. pp 156-88.
-
(1995)
Clinical Dialysis. Third Ed.
, pp. 156-188
-
-
Gotch, F.A.1
-
6
-
-
0024215653
-
Causes, kinetics and clinical implications of post-hemodialysis urea rebound
-
Pedrini LA, Zereik S, Rasmy S. Causes, kinetics and clinical implications of post-hemodialysis urea rebound. Kidney Int 1988;34: 817-24.
-
(1988)
Kidney Int
, vol.34
, pp. 817-824
-
-
Pedrini, L.A.1
Zereik, S.2
Rasmy, S.3
-
7
-
-
0029846352
-
Cardiac output and urea kinetics in dialysis patients: Evidence supporting the regional blood flow model
-
George TO, Priester-Coary A, Dunea G, Schneditz D, Tarif N, Daugirdas JT. Cardiac output and urea kinetics in dialysis patients: Evidence supporting the regional blood flow model. Kidney Int 1996;50:1273-7.
-
(1996)
Kidney Int
, vol.50
, pp. 1273-1277
-
-
George, T.O.1
Priester-Coary, A.2
Dunea, G.3
Schneditz, D.4
Tarif, N.5
Daugirdas, J.T.6
-
8
-
-
0031985518
-
Simulating the effect of exercise on urea clearance in hemodialysis
-
Smye SW, Lindley EJ, Will EJ. Simulating the effect of exercise on urea clearance in hemodialysis. J Am Soc Nephrol 1998;9:128-32.
-
(1998)
J Am Soc Nephrol
, vol.9
, pp. 128-132
-
-
Smye, S.W.1
Lindley, E.J.2
Will, E.J.3
-
9
-
-
0027493328
-
A regional blood circulation alternative to in-series two compartment urea kinetic modeling
-
Schneditz D, Van Stone JC, Daugirdas JT. A regional blood circulation alternative to in-series two compartment urea kinetic modeling. ASAIO J 1993;39:M573-7.
-
(1993)
ASAIO J
, vol.39
-
-
Schneditz, D.1
Van Stone, J.C.2
Daugirdas, J.T.3
-
10
-
-
0028468541
-
Formal analytical solution to a regional blood flow and diffusion based urea kinetic model
-
Schneditz D, Daugirdas JT. Formal analytical solution to a regional blood flow and diffusion based urea kinetic model. ASAIO J 1994;40:M667-73.
-
(1994)
ASAIO J
, vol.40
-
-
Schneditz, D.1
Daugirdas, J.T.2
-
11
-
-
0028824244
-
Is intercompartmental urea clearance during hemodialysis a perfusion term? A cpmparison of two pool urea kinetic models
-
Schneditz D, Fariyike B, Osheroff R, Levin NW. Is intercompartmental urea clearance during hemodialysis a perfusion term? A cpmparison of two pool urea kinetic models J Am Soc Nephrol 1995;6:1360-70.
-
(1995)
J Am Soc Nephrol
, vol.6
, pp. 1360-1370
-
-
Schneditz, D.1
Fariyike, B.2
Osheroff, R.3
Levin, N.W.4
-
12
-
-
0033955619
-
Analysis of urea nitrogen and creatinine kinetics in hemodialysis: Comparison of a variable-volume two-compartment model with a regional blood flow model and investigation of an appropriate solute kinetics model for clinical application
-
Yamada T, Hiraga S, Akiba T, Marumo F. Analysis of urea nitrogen and creatinine kinetics in hemodialysis: comparison of a variable-volume two-compartment model with a regional blood flow model and investigation of an appropriate solute kinetics model for clinical application. Blood Purif 2000;18:18-29.
-
(2000)
Blood Purif
, vol.18
, pp. 18-29
-
-
Yamada, T.1
Hiraga, S.2
Akiba, T.3
Marumo, F.4
-
13
-
-
0036957706
-
Estimation of filtration coefficients and circulating plasma volume by continuously monitoring hematocrit during hemodialysis
-
Yashiro M, Hamada Y, Matsushima H, Muso E. Estimation of filtration coefficients and circulating plasma volume by continuously monitoring hematocrit during hemodialysis. Blood Purif 2002;20:569-76.
-
(2002)
Blood Purif
, vol.20
, pp. 569-576
-
-
Yashiro, M.1
Hamada, Y.2
Matsushima, H.3
Muso, E.4
-
14
-
-
0026468057
-
Cardiopulmonary recirculation during hemodialysis
-
Shneditz D, Kaufmann AM, Polaschegg HD, Lewin NW, Daugirdas JT. Cardiopulmonary recirculation during hemodialysis. Kidney Int 1992;42:1450-6.
-
(1992)
Kidney Int
, vol.42
, pp. 1450-1456
-
-
Shneditz, D.1
Kaufmann, A.M.2
Polaschegg, H.D.3
Lewin, N.W.4
Daugirdas, J.T.5
-
15
-
-
0006424722
-
Variabilty and stability of two pool urea transfer coefficients
-
Star RA, Hootkins R, Thompson JR, Poole T, Toto RD. Variabilty and stability of two pool urea transfer coefficients (abstract). J Am Soc Nephrol 1992;3:395.
-
(1992)
J Am Soc Nephrol
, vol.3
, pp. 395
-
-
Star, R.A.1
Hootkins, R.2
Thompson, J.R.3
Poole, T.4
Toto, R.D.5
-
16
-
-
0000238336
-
A Simplex method for function minimization
-
Nelder JA, Mead R. A Simplex method for function minimization. Computer J 1965;7:308-13.
-
(1965)
Computer J
, vol.7
, pp. 308-313
-
-
Nelder, J.A.1
Mead, R.2
-
17
-
-
0022635770
-
Microcomputer-based nonlinear regression analysis of ligand-binding data: Application of Akaike's information criterion
-
Kamikubo K, Murase H, Murayama M, Miura K. Microcomputer-based nonlinear regression analysis of ligand-binding data: application of Akaike's information criterion. Jpn J Pharmacol 1986;40:342-6.
-
(1986)
Jpn J Pharmacol
, vol.40
, pp. 342-346
-
-
Kamikubo, K.1
Murase, H.2
Murayama, M.3
Miura, K.4
-
18
-
-
0017279676
-
Problems in echocardiographic volume determinations: Echocardiographic- angiographic correlation in the presence or absence of asynergy
-
Teichholz LE, Kreulen T, Herman MV, Gorlin R. Problems in echocardiographic volume determinations: echocardiographic-angiographic correlation in the presence or absence of asynergy. Am J Cardiol 1976;37:7-11.
-
(1976)
Am J Cardiol
, vol.37
, pp. 7-11
-
-
Teichholz, L.E.1
Kreulen, T.2
Herman, M.V.3
Gorlin, R.4
-
19
-
-
0031962966
-
Non-invasive evaluation of vessels by duplex sonography prior to construction of arteriovenous fistula for haemodialysis
-
Malovrh M. Non-invasive evaluation of vessels by duplex sonography prior to construction of arteriovenous fistula for haemodialysis. Nephrol Dial Transplant 1998;13:125-9.
-
(1998)
Nephrol Dial Transplant
, vol.13
, pp. 125-129
-
-
Malovrh, M.1
|